Laserfiche WebLink
Product Line Information ONYXWorks: UL-listed graphics PC workstation, ONYXWorks GUI <br /> software, and computer hardware. See DN-7048 for specific part <br /> • "Configuration Guidelines"on page 3 numbers. <br /> • "Main System Components"on page 3 <br /> • "Networking Options"on page 3 AUXILIARY POWER SUPPLIES AND BATTERIES <br /> • "Auxiliary Power Supplies And Batteries"on page 3 PMB-AUX: Auxiliary power supply, 6 amps, universal AC input, 4 <br /> NACs and 2 Auxiliary outputs, chassis-mounted for use in a CAB-5 <br /> • "Audio Options"on page 3 Series cabinet.Charges 7-100AH batteries.See DN-62116. <br /> • "Compatible Devices, EIA-232 Ports"on page 4 PMB-AUX-RTO:Auxiliary power supply,6 amps,universal AC input,4 <br /> • "Compatible Devices,AIO Bus"on page 4 NACs and 2 Auxiliary outputs, chassis-mounted for use in a CAB-4 <br /> • "Compatible Intelligent Devices"on page 4 Series cabinet.Charges 7-100AH batteries.See DN-62116, <br /> • "Intelligent Detector Bases"on page 4 PSE-6/10: PowerStrikeTm Remote 6A/10A power supply with battery <br /> • "Compatible Intelligent Modules"on page 4 charger.See DN-61092. <br /> • "Enclosures,Chassis,and Dress Plates"on page 5 BAT Series: Sealed lead-acid batteries listed for fire-protective ser- <br /> • "Backboxes"on page 5 vice. (Required.)See DN-6933. <br /> • "CLSS Gateway and Licensable Features"on page 5 AUDIO OPTIONS <br /> • "Communicators"on page 5 NOTE:See"Enclosures,Chassis,and Dress Plates"on page 5 for mount- <br /> CONFIGURATION GUIDELINES ing hardware. <br /> Stand-alone and network systems require a main display. The main DVC-EM: Digital Voice Command, digital audio processor with mes- <br /> display must be either NCD, ONYXWorks or one panel in the network sage storage for up to 32 minutes of standard quality (4 minutes at <br /> with Network Display mode enabled. high quality)digital audio. See DN-7045. <br /> DVC-RPU: Digital Voice Command Remote Paging Unit for use with <br /> MAIN SYSTEM COMPONENTS DVC-EM. Includes the keypad/display.See DN-60726. <br /> CPU-N16LD: N16x with display. Intelligent fire alarm with one SLC DS-DB: Digital Series Distribution Board, provides bulk amplification <br /> loop, 10" touchscreen display, 4 NACs, and power supply; chassis capabilities to the DVC-EM while retaining digital audio distribution <br /> mounted for use in a CAB-5 Series cabinet. Requires DP-T2A to capabilities. Can be configured with up to four DS-AMPs, supplying <br /> mount the display. high-level risers spread throughout an installation. See DN-60565. <br /> CPU-N16LND: N16x without display, for use as network node. Intelli- DVC-KD/B: DVC-EM keypad for local annunciation and controls; sta- <br /> gent fire alarm with one SLC loop,4 NACs,and power supply;chassis tus LEDs and 24 user-programmable buttons. Gray; order DVC-KDB <br /> mounted for use in a CAB-5 Series cabinet. for black. See DN-7045. <br /> CPU-I6-RTO: N16x with display for use in retrofit cabinets. Intelligent DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS requires <br /> fire alarm with one SLC loop, 10" touchscreen display, 4 NACs, and DS-XF70V step-up transformer. Digital Series Amplifier, part of the <br /> power supply; chassis mounted for use in a CAB-4 Series cabinet. DS-DB system. See DN-60663. <br /> Requires DP-T2A-CB4 to mount the display. DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for DVC-EM, <br /> N16E: Intelligent fire alarm panel with one SLC loop, 10"touchscreen DS-DB distribution board, and DAA2/DAX Series amplifiers. See DN- <br /> display,4 NACs, and power supply in a black enclosure. 60633. <br /> N16E-R: Intelligent fire alarm panel with one SLC loop, 10" touch- DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assembly with <br /> screen display,4 NACs, and power supply in a red enclosure. power supply; includes chassis.See DN-60556. <br /> CPU-Nl6-RB: Replacement board with central processing unit. DAA2-5070(E):50W,70.7 Vrms Digital Audio Amplifier assembly with <br /> power supply; includes chassis.See DN-60556. <br /> CPU-NCD-RB: Replacement board for NCD with central processing DAA2-7525(E): 75W, 25 Vrms digital audio amplifier assembly with <br /> unit. power supply; includes chassis.See DN-60556, <br /> DIS-IO-RD: Replacement touchscreen. DAX-3525(E): 35W, 25 Vrms Digital Audio Amplifier assembly with <br /> SLM-318: Signaling Line Module provides a Signaling Line Circuit of power supply, includes chassis. See DN-60561. <br /> 159 addressable points.Add SLM-318 units to expand SLC capability. DAX-3570(E): 35W, 70.7 Vrms Digital Audio Amplifier assembly with <br /> See DN-62115. power supply, includes chassis. See DN-60561. <br /> NETWORKING OPTIONS DAX-5025(E): 50W, 25 Vrms Digital Audio Amplifier assembly with <br /> NCD: Network Control Display.On network systems(two or more net- power supply, includes chassis. See DN-60561. <br /> worked fire panel nodes), one network display is required for every DAX-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assembly with <br /> system (either NCD,ONYXWorks,or N16 with Network Display mode power supply, includes chassis. See DN-60561. <br /> enabled). On network systems, the NCD connects (and requires) a TELH-1: Firefighter's Telephone Handset for use with the DVC EM <br /> Communication Module. See DN-60974. <br /> standard Network Communication module or High-Speed Network when mounted in the C el M chassis. See DN 7045. <br /> NCM-W, NCM-F: Standard Network Communications Modules. Wire RM-11/11M-1SA: Remote microphone assemblies, mount on ADP-4 <br /> and multi-mode fiber versions available.See DN-6861. (RM-1) dress panel or CAB-RM/-RMR (RM-1 SA) stand-alone cabi- <br /> nets. See DN-6728. <br /> HS-NCM-W-2, HS-NCM-MF, HS-NCM-SF, HS-NCM-WMF-2, HS- <br /> NCM-WSF-2, HS-NCM-MFSF: High-speed Network Communications DAA Series Digital Audio Amplifiers: Legacy DAA Series amplifiers <br /> Modules that can connect to two nodes.Wire,single-mode fiber,multi- are compatible with DVC systems running SR4.0. For specific informa- <br /> mode fiber, and media conversion models are available. See DN- tion on DAA-50 series amplifiers, refer to DN-7046. For information on <br /> 60454. DAA-7525 Series, refer to DN-60257. <br /> RPT-W, RPT-F, RPT-WF: Standard-network repeater board with wire DAX-3525(E): 35W, 25 Vrms Digital Audio Amplifier assembly with <br /> connection(RPT-W),multi-mode fiber connection(RPT-F),or allowing power supply, includes chassis. See DN-60561. <br /> a change in media type between wire and fiber (RPT-WF). Not used DAX-3570(E): 35W, 70.7 Vrms Digital Audio Amplifier assembly with <br /> with high-speed networks. See DN-6971. power supply, includes chassis. See DN-60561. <br /> DN-62112:E•7/11/2022—Page 3 of 6 <br />