i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> Permit Number: P2307-027 Description: REPLACE CAST PIPES UNDER HOUSE <br /> Applied:7/26/2023 Approved:7/26/2023 Site Address: 1622 COLBY AVE <br /> Issued:7/26/2023 Finaled:9/5/2023 City,State Zip Code:EVERETT,WA 98201 <br /> Status: FINALED Applicant:Jason Kennedy <br /> Parent Permit: Owner: KENNEDY JASON&KENDRA <br /> Parent Project: Contractor:APOLLO PLUMBING LLC <br /> Details: <br /> SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS <br /> 7/28/2023 7/28/2023 PLUMB 08-FINAL JASON CORRECTION <br /> MORRISSEY REQUIRED <br /> Notes: <br /> -There is no visible vent tie in downstream of trap for tub.All traps are required to be vented.As a result the11/2"tub trap arm exceeds 42"limit.Per <br /> UPC 1002.1 Vent Pipes,and 1002.2 Fixture Traps.The drain must upsize tot"pipe at the intersection of the tub vent per Table703.2 Maximum Number <br /> of Fixture Units <br /> Support horizontal drain pipe every4'per the UPC Table 313.3 Hangers and Supports <br /> Section of 2"drain in crawlspace for washing machine is back graded.All drain pipe is to be graded at2%slope per the UPC 708.1 <br /> 9/1/2023 9/1/2023 PLUMB 08-FINAL JASON APPRVD-PERMIT <br /> MORRISSEY FINAL <br /> Notes: <br /> JASONFJ55@YAHOO.COM <br /> I <br /> Printed:Tuesday,05 September, 2023 1 of 1 rk <br /> SUPERION <br />