111, <br /> PIN • 0 <br /> www.weaverarch.com <br /> ARCHITECTS <br /> Pier 55 1101 Alaskan Way, Suite 300 Seattle Washington 98101 p. 206.262.9622 <br /> October 12, 2021 <br /> Drew Martin D [©LII V[ <br /> City of Everett Permit Services <br /> 3200 Cedar Street, 2nd Floor OCT 1 5 2021 <br /> Everett, WA 98201CITY OF EVERETT <br /> Re: 3301 Seaway Blvd (B2108-001) Permit Services <br /> Review Comments: <br /> 1. The proposed project appears to involve installing two prefabricated rooms with lids in an existing <br /> building. The submitted documents are not sufficient to show the proposed work. Sheet A.9A.1 only <br /> shows isometric views of the framing for the two "DYNO"rooms;the Control Room is not shown. In <br /> addition this sheet shows the rooms as "existing"with minor modifications. Architectural and <br /> structural plans for the rooms should be provided showing compliance with the applicable <br /> requirements of the IBC. Additional comments are provided below, but these are not intended as a <br /> comprehensive list of all requirements that may apply to this project. <br /> 2. Architectural plans for the rooms should be provided. Information to be specified includes but is not <br /> limited to: <br /> a. Construction Type per IBC Chapter 6. The construction should be consistent with the <br /> permitted type for the building. <br /> b. Occupancy classification(s) for the rooms and the proposed uses. The occupancy(s)and <br /> uses should be consistent with the permitted classification for the building, or as otherwise <br /> allowed by IBC Chapter 5. <br /> c. Egress doors <br /> 3. Structural plans, including sections and details, and calculations should be submitted for review. The <br /> plans and calculations should demonstrate compliance with IBC Chapter 16,ASCE 7-16, and the <br /> applicable reference standards for the proposed material(e.g., steel, etc.). The lateral system should <br /> comply with ASCE 7-16 Section 12.2.1. <br /> Responses: <br /> 1. The two rooms are already fabricated and are being relocated from another location. We have <br /> added additional documents, plans and sections to further illustrate how they were fabricated and <br /> their size and function as requested. <br /> 2. See the additional project information added to the set and plans/elevations/section added in <br /> sheets A.2A.1,A.3.0,A.9A.1,A.9A.2, and A.9A.3. <br /> 2a: The materials in the units meet the requirements for Type IIIB per IBC 602.3 Type II that allows <br /> "interior building elements are of any material permitted by this code." Framing components are all <br /> non-combustible steel members. <br /> 2b: The units are for testing components associated with the type Factory occupancy already <br /> established. The components are part of both aircraft manufacturing and electronics as listed in IBC <br /> 306.1 under Factory and are not a change of use. <br />