My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2219 106TH ST SW 2023-09-14
>
Address Records
>
106TH ST SW
>
2219
>
2219 106TH ST SW 2023-09-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/14/2023 2:41:37 PM
Creation date
9/7/2023 6:29:14 AM
Metadata
Fields
Template:
Address Document
Street Name
106TH ST SW
Street Number
2219
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_-.-_-_-_-"-_-___I <br /> Everett Fire Dept.Notes: Permit#: FA2306-025 <br /> i(NEPA 72) I Site Address: 2219 106th lig Inc �� <br /> EVERETT Applicant Sea8/2023linglSeaCom <br /> ❑See Attached Fire Alarm System Application Date:06/28/2023 If CABLING TECHNOLOGY SOLUTIONS <br /> Acceptance Test Checklist. Description: Install New Addressable Fire Alarm System <br /> 1912 Everett Avenue-Suite 120 <br /> u24 hour Battery Test-At the time of the Review Status: tat Review by City&Peer Reviewers Everett,WA 98201 <br /> inspection/test provide proof verifying that the i Review Date: 06/28/2023 <br /> Phone 425.317.8259 <br /> panel has been operating on secondary power Lic.SEACOC1944D0 <br /> (battery)for 24 hours.No other problems <br /> ishall be indicated on the panel. <br /> ❑Record of Completion-For all new I EV R TT <br /> systems,a Record of Completion is required <br /> to be entered into The Compliance Engine I Everett Fire Dept.Permit Review <br /> prior to permit final. Status:Approved <br /> i(www.thecompllanceengine.com) I Reviewed By:KBrown <br /> 06/28/2023 1:10:40 <br /> I_'__—_—_—_--------- PM <br /> EXISTING GARAGE <br /> ------------------------------------ <br /> O /-( <br /> x�- <br /> 75CD �. '�O` 75C0 � ]5C0 � 75CD <br /> 750D BLDG 1 75CBLDG 2 BLDG 3 <br /> 0 0 EXISTING BATHROOM <br /> DRIVE <br /> w w w <br /> I � I <br /> O O O1-1/2 CONDUIT <br /> W/#14 HHN <br /> 175C �` 75CD p` 75CD M ] �` 5CD 5CD <br /> Q DOQ i EXIS <br /> TO I <br /> -- ---.--.-.-- - - 135CD <br /> T- ------------ ---„-' j( 135CD 5CD <br /> -.-�--I - '� 13 <br /> J J J <br /> L--------------�7VC CONDUIT -------- t-1/2”J ------------------------ PVCCONDUIT ------------------------J J <br /> L1-1/2"P <br /> W/#14 THHN W/#14 THHN <br /> FIRE ALARM PLAN <br /> i �y I r <br /> SCALE:1"=20'-0" I..L <br /> wz <br /> 0- w <br /> 0 <br /> � 00 <br /> x EQUIPMENT LEGEND WIRE LEGEND s <br /> d DEVICE 300 <br /> QUANTITY PART NUMBER DESCRIPTIONBACKBO% L TYPE DESCRIPTION 1 r IJ 1 A <br /> SYMBOL (D <br /> Y <br /> FACP 1 1—.. FIRE ALARM CONTROL PANEL INCLUDED A 18 AWG, 2 CONDUCTOR 'FPLR' JACKETED CABLE w O +�+ <br /> B 14 AWG, 2 CONDUCTOR 'FPLR' JACKETED CABLE W <br /> o C 18 AWG, 4 CONDUCTOR 'FPLR' JACKETED CABLE W 0 r <br /> O 1 PAD100-PD SMOKE DETECTOR 4 SQUARE X 1-7/8"DEEP N ' <br /> 8 © 4 PAD100-PSSA MANUAL PULL STATION SINGLE GANG w (N W <br /> ,,I--I GENERAL NOTES: Issues <br /> 'LJ� 12 CHS-24-W CEILING HORN STROBE 4 SQUARE X 1-7/8"DEEP <br /> ..,,��II 1. ALL WORK IS TO CONFORM TO NATIONAL ELECTRIC CODE STANDARDS. <br /> rL•J� 3 5-24-WR-WP WEATHERPROOF HORN STROBE 4 SQUARE X 1-7/8"DEEP <br /> 2. WIRING METHOD IS TO BE OPEN CABLING EXCEPT WHERE IT IS EXPOSED AND BELOW SEVEN FEET - THEN IT IS TO <br /> O 12 PAD100-HD HEAT DETECTOR SINGLE GANG BE IN CONDUIT. <br /> (*) PROVIDED AND INSTALLED BY OTHERS 3. ALL JUNCTION BOXES, COVERS,AND BACK BOXES ARE TO BE PAINTED RED. <br /> 4. PULL STATIONS ARE TO BE MOUNTED AT 48"TO 53"ABOVE THE FLOOR. TITLE: <br /> --------- EXISTING DEVICE TO REMAIN <br /> NEW OR EXISTING DEVICE RELOCATED 5. ALL WALL MOUNT INDOOR HORNS, STROBES, HORN STROBES,AND SPEAKER STROBES ARE TO BE MOUNTED 80 FIRE ALARM <br /> ABOVE THE FLOOR OR 6"BELOW THE CEILING,WHICHEVER IS LOWER. <br /> / INDICATES CANDELA PLAN <br /> 6. SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING: <br /> g (E) INDICATES EXISTING A) 36"INCHES AWAY FROM ANY AIR HANDLING SYSTEM DIFFUSER <br /> 9 C INDICATES CEILING MOUNT B) NOT IN CLOSE PROXIMITY TO ANY FLUORESCENT LIGHT FIXTURES <br /> Y <br /> - 7. EXTERIOR HORN/STROBE SHALL BE MOUNTED ON THE TOP 2/3 OF THE OUTSIDE WALL OF THE BUILDING,AS HIGH <br /> AS POSSIBLE FOR MAXIMUM VISIBILITY FROM THE FIRE DEPARTMENT ACCESS ROADWAY. DATE: <br /> 8 <br /> 1 <br /> 8. ALL WIRING PENETRATING ANY FIRE RATED BARRIER SHALL BE SEALED WITH MATERIAL WHICH WILL PREVENT PASSAGE NOVEMBER 2,2016 <br /> � OF FLAME AND HOT GASES. PROJECT NO.: <br /> u 16-050 <br /> 0 <br /> SHEET: <br /> O 0 20' 40' FA— 1 <br /> OoSCALE: 1"=20'-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.