SILENT Global Project Values: <br /> Project Name: Everett-Construction Storage Standby Hours:KNIGHT 24 <br /> Project ID: Alarm Mins:0 �5 <br /> Prepared By: Troy Johnson Derating Factor: 1.2 <br /> 5808 Calculations Date: 10/27/2016 Voltage Drop Warning <br /> Version 10.24.14 Threshold%: 10 <br /> Panel ID: IIPA4000 Model: 5808 Add.Fire Alarm Control Panel Max NAC Current: 3.0 Amps <br /> Location: INE Corner Electrical Room I Volts: 24 VDC Max Panel Current: 5.0 Amps <br /> Ckt.# Circuit Name Qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop <br /> Standby Alarm &Type 1000 Ft. One-Way Ohms EOL <br /> IPA4000 IPA4000 CTRL PANEL 1 0.170 0.365 <br /> Addr. Input Mod 0.000 0.000 <br /> Mini-Input Module 0.000 0.000 <br /> Addr.Relay Module 0.000 0.000 <br /> PAD100-PSSA Addr.Pull Station 4 0.002 0.002 <br /> Addr. Ion Smoke Det 0.000 0.000 <br /> Addr.Beam Detector 0.002 0.002 <br /> PAD100-PD Addr.Photo Smoke Det 1 0.001 0.001 <br /> Addr. Heat Detector 12 0.001 0.012 <br /> Addr.Duct 0.000 0.000 <br /> Addr.Notification Module 0.000 0.000 <br /> Addr.LED Module 0.000 0.000 <br /> Addr.Smoke Det.Mod. 0.000 0.000 <br /> Addr.Det.Relay Base 0.000 0.000 <br /> Addr.Det.Sounder Base 0.000 0.000 <br /> Addr.Det. Isolator Base 0.000 0.000 <br /> Line Isolation Module 0.000 0.000 <br /> LCD Remote Annunc 0.000 0.000 <br /> Serial/Parallel Module 0.000 0.000 <br /> Power Expander 0.030 0.030 <br /> Power Expander 0.000 0.000 <br /> LED Annunciator(4G) 0.000 0.000 <br /> LED Annunciator(3G) 0.000 0.000 <br /> LED Driver Module 0.000 0.000 <br /> Relay Module 0.000 0.000 <br /> NAC#1 lAux Power Circuit 0.000 0.741 #14 Solid 2.52 0.00 20.40 N/A <br /> NAC#2 Aux Power Circuit 0.000 0.741 #14 Solid 2.52 0.00 20.40 N/A <br /> NAC#3 Aux Power Circuit 0.000 0.741 #12 Solid 1.59 0.00 20.40 N/A <br /> NAC#4 Aux Power Circuit 0.000 0.000 #12 Solid 1.59 0.00 20.40 N/A <br /> Total Standby Current(Amps) 0.204 2.622 Total Alarm Current(Amps) <br /> Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 (5 Mins) <br /> Total Standby AH Required 4.906 0.219 Total Alarm AH Required <br /> Total Combined AH Required 5.12 Command Shortcuts <br /> Multiply By The Derating Factor 1.20 <br /> Minimum Battery AmpHours Required 6.15 Configure Circuits Print Page <br />
The URL can be used to link to this page
Your browser does not support the video tag.