• GAS METER LOCATED IN PROXIMITY OF THE PV INSTALLATION,LOAD CENTER,AND/OR AMBIENT TEMPERATURE SPECIFICATIONS SOLAR MODULE SPECIFICATIONS <br /> DISCONNECTS.DISCONNECTS SHALL BE LOCATED IN COMPLIANCE WITH UTILITY AND THE AHJ <br /> (AUTHORITY HAVING JURISDICTION).PV INSTALLATION SHALL COMPLY WITH ALL APPLICABLE CONDUCTOR CONDUCTOR TEMPERATURE #OF LUM10 <br /> CODES. RECORD AMBIENT TEMP TEMPERATURE TEMPERATURE MANUFACTURER/MODEL# VMP IMP VOC ISC COEFFICIENT <br /> • WIRE RATED AND AMPACITY CALCULATED @ 90°C FOR ROOFTOP INSTALLATION AND ATTIC RUN LOW TEMP (HIGH TEMP 2%) RATE(ON RATE(OFF OF Voc MODULES <br /> TO INVERTER. ROOF) ROOF) HANWHA Q CELLS Q.PEAK DUO <br /> • PER NEC REQUIRMENTS GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BE BLK ML-G10+(400W) 37.13 10.77 45.30 11.14 -0.27%/'K 18 <br /> PROTECTED IN A CONDUIT,RACEWAY,OR ARMORED PROTECTIVE SHEATHING(NEC 250.64). -5° 26° 90° 75° <br /> • THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE MODULE DIMENSION 74.0"L x 41.1"W x 1.26"D <br /> NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. <br /> • ANY CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT.(NEC <br /> 300.6 C1,310.8 D). SERVICE INFO. NOTE:THE AC DISCONNECT IS LOCATED <br /> • ROOM FOR EQUIPMENT WITHIN 5 FEET FROM MSP. SYSTEM SIZE:-18 x 40OW=7.200 kWDC <br /> • ALL CONDUIT SHALL BE EMT 3/4"IN DIAMETER UNLESS OTHERWISE STATED. UTILITY PROVIDER: SNOPUD 18 x 290VA=5.220 kWAC WITHIN 10FT OF UTILITY METER <br /> MAIN SERVICE VOLTAGE: 240V <br /> MAIN PANEL BRAND: GENERAL ELECTRIC <br /> NOTE: MAIN SERVICE PANEL: (E)200A <br /> 3/4"OR GREATER EMT CONDUIT MAIN CIRCUIT BREAKER RATING: (E)200A <br /> RUN (7/8"ABOVE ROOF SURFACE) MAIN SERVICE LOCATION: NORTH-WEST <br /> SERVICE FEED SOURCE: OVERHEAD <br /> AC DISCONNECT SHALL BE LOCATED <br /> WITHIN 10'OF UTILITY METER BI-DIRECTIONAL VERSION <br /> UTILITY METER <br /> 1-PHASE,3-W, DESCRIPTION DATE REV <br /> 120V/24OV,60Hz INITIAL RELEASE 06/20/2023 UR <br /> (N)ENPHASE IQ <br /> 09 MICRO-INVERTERS IN BRANCH#1 COMBINER BOX 4 <br /> X2-IQ-AM 1-240-4 <br /> (IEEE1547:2018)[240V] <br /> LINE SIDE TAP <br /> 10A/15A <br /> (N)60A FUSED AC <br /> — — <br /> 7ipl_ <br /> (N)JUNCTION BOX DISCONNECT WITH 30A <br /> 20A FUSES,240 VAC (E)MAIN BREAKER <br /> L1 L1 200A/2P,240V <br /> 30A FUSES 200AF{ <br /> 09 MICRO-INVERTERS IN BRANCH#2 L L2 20A L1 L1 <br /> (E)MAIN PROJECT NAME <br /> L1 L1 SERVICE PANEL, <br /> L2 L2 � 200A RATED, <br /> L L2 0 120/240V <br /> LID <br /> • • • N N o = (�[ <br /> - — G G U) O <br /> L — M' IQ GATEWAY Q 5 w O <br /> G N o M H o O <br /> 01) CD LU <br /> (18)ENPHASE IQ8PLUS-72-2-USA B C <br /> MICRO-INVERTERS(240V) EXISTING = Q r, W LL m <br /> (LOCATED UNDER EACH PANEL) SYS EM GROUNDING (_0O O <br /> BRANCH TERMINATOR Q TERM Q 0 ~ O ~ ~ z <br /> FOR IQ SERIES(TYP.) LU z U U <br /> LU LU LLJ <br /> O LU Q O <br /> Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire <br /> Wire Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC (A) Correction Current(A) Size Type <br /> SHEET NAME <br /> A OPEN AIR 2 12 AWG Q Cable 90°C 30 1 N/A 30.00 09 1.21 1.25 13.61 06 AWG BARE CU ELECTRICAL LINE <br /> DIAGRAM & <br /> B 3/4" EMT 4 12 AWG THWN-2 90°C 40 1 0.8 32.00 09 1.21 1.25 13.61 6 AWG THWN-2 CALCULATION <br /> C 3/4" EMT 3 6 AWG THWN 75°C 65 1 1.0 65.00 18 1.21 1.25 27.23 6 AWG THWN SHEET SIZE <br /> ANSI B <br /> 11" X 17" <br /> 1 ELECTRICAL LINE DIAGRAM WITH CALCULATION SHEET NUMBER <br /> SCALE: NTS PV-4 <br />