Laserfiche WebLink
DOMINO'S PIZZA BAKERY STORE #7134 <br /> • , PIZZA THEATER TENANT IMPROVEMENT <br /> TM <br /> [)Orninos 1801 N BROADWAY AVE <br /> GNICH <br /> EVERETT, WA 98201 IS THI�T�ECDTUROE <br /> OREGON QMPANY <br /> GENERAL CONDITIONS: GENERAL NOTES: PROJECT DIRECTORY: DRAWING INDEX: PROJECT STATISTICS: RESPONSIBILITY SCHEDULE N <br /> 1. IT IS THE RESPONSIBILITY OF THE GENERAL 1.THE OWNER HAS REQUESTED THAT THE ARCHITECT OWNER/DEVELOPER GENERAL INFORMATION SCOPE ITEM o REMARKS <br /> " CONTRACTOR AND SUBCONTRACTORS TO MAKE PREPARE THESE DRAWINGS,WHICH ARE LIMITED IN w w S S°y <br /> v THEMSELVES FAMILIAR WITH THE GENERAL CONDITIONS, SCOPE,TO ESTABLISH MINIMUM GUIDELINES FOR DESIGN UPC LLC G1.0 COVER SHEET THIS DOMINO'S PIZZA THEATER TENANT IMPROVEMENT 3 0o <br /> o �S" - 0 1001 SE SANDY BLVD.,SUITE 100 <br /> PLANS,AND SPECIFICATIONS AND OTHER NOTES OR OF THE PROJECT. P.O.BOX 497 G2.0 CONSTRUCTION SPECIFICATIONS/ACCESSIBILITY PROJECT INCLUDES;THE ADDITION OF NEW INTERIOR m ''FZ �¢� <br /> �¢� PORTLAND,OR 97214 <br /> REFERENCES RELATED TO THIS PROJECT SO AS TO MARYSVILLE,WA 98270 DETAILS PARTITIONS,CASEWORK,FIXED FURNITURE,KITCHEN o 21 o o��m�`�'�»�c�i V.503 552 9079 <br /> POSSESS FULL COMPREHENSION OF THE WORK THEY ARE 2.WHERE MATERIALS,ASSEMBLIES,EQUIPMENT, TEL: 360 589-1761 EQUIPMENT,PLUMBING FIXTURES,ELECTRICAL s J s s yswyai"s <br /> ( ) o o o y ro II II II,I°,I F. 503.241.7055 <br /> TO PERFORM.ANY DISCREPANCIES SHALL BE IMMEDIATELY FIXTURES AND SYSTEMS ARE NOT SHOWN,OR ARE E:CHRIS.F@JPCPIZZA.COM ARCHITECTURAL DISTRIBUTION AND MECHANICAL SYSTEMS FOR ARETAIL - -- WWW.GNICHARCH.COM <br /> BROUGHT TO THE ATTENTION OF THE ARCHITECT. SHOWN DIAGRAMMATICALLY,IT IS THE RESPONSIBILITY FOOD BAKERY AND STORE. DIVISION p1-GENERAL REQUIREMENTS <br /> OF THE GENERAL CONTRACTOR TO DETERMINE SPECIFIC ARCHITECT CONTACT INFORMATION FLS1.0 FIRE/LIFE SAFETY PLAN PERMITS,FEES,AND INSURANCE • <br /> 2. NOTHING IN THE PLANS,SPECIFICATIONS,NOTES OR LOCATIONS,PROVIDE SPECIFIC MATERIALS AND A1.0 EQUIPMENT LAYOUT/SCHEDULES CODE SUMMARY PROFESSIONAL CLEANING • <br /> REFERENCES SHALL BE INTERPRETED SO AS TO ELIMINATE DETERMINE CONSTRUCTION DETAILING,ALL IN GNICH ARCHITECTURE STUDIO,LLC A2.0 PARTITION&FINISH PLAN/ TEMPORARY POWER/WATER •• 08.05.21 <br /> ANY REQUIREMENTS OR PROVISIONS OF NATIONAL,STATE, COMPLIANCE WITH APPLICABLE BUILDING CODES, AN OREGON LIMITED LIABILITY COMPANY DETAILS/MATERIAL SCHEDULE/DOOR SCHEDULE BUILDING CODE 2018IBC W/WA AMENDMENTS CERTIFICATE OF OCCUPANCY • <br /> 20181EBC W/WA AMENDMENTS DUMPSTER/TRASH REMOVAL •• <br /> COUNTY,OR LOCAL BUILDING CODES AND ORDINANCES. REGULATIONS,AND INDUSTRY STANDARDS FOR 1001 SE SANDY BLVD,SUITE 100 A3.0 REFLECTED CEILING PLAN/DETAILS BB11 1FGIST8IFD <br /> ALL CONTRACTORS ARE RESPONSIBLE FOR FULL MATERIALS AND METHODS OF INSTALLATION. PORTLAND,OR 97214 A4.0 INTERIOR ELEVATIONS/ART PACKAGE MECHANICAL CODE 20181MC W/WA AMENDMENTS AACHITEC <br /> E KNOWLEDGE OF,AND COMPLIANCE WITH THE PLUMBING CODE 2018 UPC W/WA AMENDMENTS DIVISION SITE WORK <br /> TEL: (503)552-9079 SCHEDULE ENERGY CODE 2018 WASHINGTON STATE TRENCHING AND BACKFILL <br /> AFOREMENTIONED REGULATIONS AND SHALL NOTIFY THE 3.ALL DRAWINGS HAVE BEEN PREPARED WITH THE FAX: (503)241-7055 A5.0 INTERIOR ELEVATIONS/COUNTER CABINETS - -- <br /> ARCHITECT OF ANY DISCREPANCIES OR CONFLICTS BEFORE INTENT OF CURRENT CODE COMPLIANCE. IT IS THE ATTN: MICHAEL WOODALL,PROJECT MANAGER A6.0 INTERIOR DETAILS ENERGY CODE SHORING AND SPACING •• asoT1 D.Gnich <br /> BEGINNING THEIR WORK. RESPONSIBILITY OF THE GENERAL CONTRACTOR TO MICHAELW GNICHARCH.COM FUEL GAS CODE 20181FGC W/WA AMENDMENTS TEMPORARY BARRICADES •• COORDINATE REQUIREMENTS w/CITY AUTHORITIES TATE OF WASHINGTON <br /> @ FIRE CODE 2018 IFC W/WA AMENDMENTS PAVING PATCHmGANO REPAIR • ExP,oa.z9.z2 <br /> ENSURE FULL COMPLIANCE WITH PREVAILING STATE OR ELECTRICAL <br /> 3.THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS LOCAL CODE REQUIREMENTS. ELECTRICAL CODE 2020 NEC W/WA AMENDMENTS <br /> SHALL VISIT THE SITE TO VERIFY ALL FIELD CONDITIONS SUBMITTALS BY OTHERS: E1.0 ELECTRICAL ONE-LINE DIAGRAM/PANEL DIVISION 03-CONCRETE <br /> _ AND DIMENSIONS RELATED TO THEIR WORK.THE GENERAL 4. DO NOT SCALE THE DRAWINGS. CUTTING • AS REQUIRED <br /> . IF DIMENSIONAL SCHEDULE/CALCULATIONS ICC Al17.1-2009 ACCESSIBLE AND USABLE BUILDINGS FLOOR su <br /> CONTRACTOR SHALL THEN SUBMIT A WRITTEN PROPOSAL DISCREPANCIES ARISE,CONTACT THE ARCHITECT. EXTERIOR SIGNAGE E2.0 ELECTRICAL LIGHTING PLAN AND FACILITIES CONCRETESus 11INGANDREPAIR •• <br /> OF HIS SCOPE OF WORK TO DOMINO'S FOR AN APPROVAL. E3.0 ELECTRICAL POWER PLAN <br /> ANY DISCREPANCIES OR CONFLICTS SHALL BE REPORTED 5. DIMENSIONS OF THE EXISTING TENANT SPACE AND SIGN VENDOR SHALL BE RESPONSIBLE FOR PREPARING DOMINO'S PIZZA BAKERY IS INTENDED PRIMARILY FOR DIVISION p4-MASONRY <br /> _ TO THE ARCHITECT BEFORE BEGINNING CONSTRUCTION. NEW DIMENSIONS WHICH RELATE TO THOSE EXISTING DRAWINGS AND OBTAINING SEPARATE SIGNAGE PERMITS DELIVERY AND CARRY OUT WITH MINIMAL SEATING FOR CLAY MASONRY UNITS •• <br /> DIMENSIONS ARE ASSUMED AND TAKEN FROM AS REQUIRED BY LOCAL JURISDICTION. MECHANICAL WAITING CUSTOMERS. CONCRETE MASONRY UNI TS •• <br /> 4.THE GENERAL CONTRACTOR SHALL CONSULT WITH THE INFORMATION PROVIDED BY THE OWNER OR OWNERS M1.0 MECHANICAL SCHEDULES,CALCULATIONS AND <br /> SUBCONTRACTORS AND COORDINATE THE WORK IN ORDER REPRESENTATIVES. IT IS IMPERATIVE THAT PRIOR TO FIRE ALARM SYSTEM IBC SECTION 303.1 DlwsloN ps-METALS <br /> LEGEND EXCEPTION 1.A BUILDING OR TENANT SPACE USED FOR <br /> TO ADHERE TO THE SCHEDULE AGREED UPON BY DOMINO'S. THE ORDERING OF PREFABRICATED EQUIPMENT OR LIGHT GAUGE METAL FRAMING •• <br /> M2.0 MECHANICAL PLAN ASSEMBLY PURPOSES WITH AN OCCUPANT LOAD OF <br /> COMMENCING CONSTRUCTION THESE DIMENSIONS ARE DESIGN/BUILT.G.C.SHALL BE RESPONSIBLE FOR M3.0 MECHANICAL DETAILS AND SEQUENCE OF cola FORMED METAL FRAMING •• <br /> 5.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE FIELD VERIFIED TO AVOID CONFLICTS. PREPARING DRAWINGS AND OBTAINING ALL BUILDING LESS THAN 50 PERSONS SHALL BE CLASSIFIED AS A <br /> FOLLOWING: PERMITS AS REQUIRED BY LOCAL JURISDICTION. OPERATIONS GROUP B OCCUPANCY. <br /> = M4.0 MECHANICAL DETAILS DIVISION OB-WOODANO PLASTICS <br /> 6.ANY DISCREPANCIES BETWEEN PORTIONS OF THE M5.0 MECHANICAL GENERAL NOTES AND MISCELLANEOUS BLOCKING •• <br /> A. PROVIDE SCHEDULE OF WORK TO DOMINO'S DOCUMENTS ARE NOT INTENDED.THE GENERAL KITCHEN HOOD FIRE SUPPRESSION SYSTEM SPECIFICATIONS BUILDING DATA wooD MOLDINGS AND TRIM •• <br /> PRIOR TO COMMENCING CONSTRUCTION. CONTRACTOR IS TO CLARIFY WITH THE ARCHITECT ANY FRAMING LUMBER •• <br /> SUCH DISCREPANCIES PRIOR TO COMMENCING WORK. DESIGN/BUILT.G.C.SHALL BE RESPONSIBLE FOR CONSTRUCTION TYPE VB FIRE RETARDANT LUMBER/PLYWOOD •• <br /> B.OBTAINING ANY AND ALL PERMITS. PREPARING DRAWINGS AND OBTAINING ALL BUILDING PLUMBING AUTOMATIC SPRINKLER SYSTEM NO MILLWORK • • <br /> 7.ALL DIMENSIONS ARE TO FACE OF STUD UNLESS PERMITS AS REQUIRED BY LOCAL JURISDICTION. PVCTRIM,CHNRRAILANDCORNER GUARDS •• 10 <br /> C. SCHEDULING ALL INSPECTIONS. OTHERWISE NOTED OR LABELED FINISHED OPENING P1.0 PLUMBING LEGEND,CALCULATIONS AND TOTAL AREA OF DOMINO'S TENANT SPACE: \-J <br /> o (F O) SCHEDULES 2,110 S.F.GROSS DIVISION 07-THERMAL AND MOISTURE PROTECTION <br /> P2.0 POTABLE WATER&GAS PLUMBING PLAN 01 <br /> D. PROVIDING CERTIFICATE OF OCCUPANCY AND INSUTATION(DUCTWORK) •110 11 11 H <br /> _ FINAL HEALTH INSPECTION. 8.ALL CONSTRUCTION SHALL COMPLY WITH THE P2.1 SANITARY SEWER PLUMBING PLAN OCCUPANT LOAD SUMMARY SEALANTS,FIRESTOPPINGANDCAULKING •• 00 <br /> _ APPLICABLE BUILDING CODES AND LOCAL P3.0 PLUMBING DETAILS BATT,RIGID AND FOAMED INSULATION •• IF REQUIRED .yL� <br /> E.THE CONTRACTOR SHALL PROVIDE THE DESCRIPTIONS. P4.0 PLUMBING SPECIFICATIONS OCCUPANCY CLASSIFICATION: GROUP B(LESS THAN 50 SOUND BATT INsuunON •• IF REQUIRED 'T- 10 <br /> a FOLLOWING WITH FINAL INVOICE: AND GREASE INTERCEPTOR SIZING&DATA OCCUPANTS) <br /> E 1)ORIGINAL OR CLEAR PHOTO COPIES OF 9.ALL ELECTRICAL,MECHANICAL AND PLUMBING WORK DIVISION 08-DOORS AND WINDOWS <br /> CERTIFICATE OF OCCUPANCY PERMIT AND SHALL CONFORM TO STATE AND LOCAL REQUIREMENTS. IBC SECTION 303.1 DOOR HARDWARE AND EXT DEVICES •• L <br /> HEALTH INSPECTION REPORT. EXCEPTION 2.A ROOM OR SPACE USED FOR ASSEMBLY IGiarEaloR DOORS FRAMES •• O <br /> 2)LISTING OF SUBCONTRACTORS AND AREA 10.CONSTRUCTION MAY NOT BEGIN UNTIL APPROVAL PURPOSES WITH AN OCCUPANT LOAD OF LESS THAN 50 O <br /> OF RESPONSIBILITY,COMPLETE WITH TRADE HAS BEEN GRANTED BY DOMINO'S.THESE DRAWINGS PERSONS AND ACCESSORY TO ANOTHER OCCUPANCY } cDD <br /> NAME,OWNER'S NAME,ADDRESS, ARE SUBJECT TO DOMINO'S APPROVAL. SHALL BE CLASSIFIED AS A GROUP B OCCUPANCY OR AS DIVISION 09-FINISHES (n N o. <br /> TELEPHONE NUMBER AND FEDERAL ID NUMBER. PART OF THAT OCCUPANCY. ACOUSTICAL CEILINGS AND SUSPENSION SYSTEMS •• j <br /> 3)PROPERLY EXECUTED LIEN WAIVER. EXCEPTION 3.A ROOM OR SPACE USED FOR ASSEMBLY GYPSUM BOARD IWALLS.SOFFITS AND CEILINGS) •• > <br /> 4)SERIAL NUMBERS,DATE OF MANUFACTURE PURPOSES THAT IS LESS THAN 750 SQUARE FEET IN FLOORTILE •• <br /> OF ALL INSTALLED HVAC EQUIPMENT, AREA AND ACCESSORY TO ANOTHER OCCUPANCY SHALL VINYLAND/oR SEAMLESS BASE •• <br /> - MAKELINE AND WALK-IN COOLER BOX. BE CLASSIFIED AS A GROUP B OCCUPANCY OR AS PART REDUCERS AND TRANSITION •• 0 Q N <br /> OF THAT OCCUPANCY. PANTSANDCOARNGS •• <br /> _ 6. UNLESS INDICATED"BY OTHERS"ON THE PLANS OR IN SHEET coons •• Lo N E <br /> THE SPECIFICATIONS OR OTHERWISE DIRECTED BY SYMBOL LEGEND LOBBY AREA _+ Lu <br /> DOMINO'S,THE GENERAL CONTRACTOR AND GROSS AREA=324 S.F. DIVISION 10-sPEOALnes <br /> r SUBCONTRACTORS SHALL SUPPLY ALL LABOR AND LOAD FACTOR @ 1/100 BUSINESS EXTERIOR SIGNAGE •• ,L 0 <br /> MATERIALS AND MISCELLANEOUS ITEMS,NOT SPECIFICALLY EXTERIORAWNING • • IF REQUIRED 0 n <br /> qp. SECTION REFERENCE OCCUPANT LOAD=4 C Q N <br /> SHOWN ON THE PLANS OR IN THE SPECIFICATIONS BUT INTERIOR GRAPHICS PACKAGE(DOOR SIGNS,ETC.) • • m ^l <br /> ACCESSIBILRV SIGNAGE •• W 01 <br /> OBVIOUSLY NECESSARY FOR THE COMPLETE AND PROPER PRODUCTION AREA Z � O` <br /> 0o DOOR SCHEDULE REFERENCE TOILET ROOM ACCESSORIES •• N ` <br /> INSTALLATION OF THEIR ELEMENTS OF WORK. GROSS AREA=809 S.F. <br /> CENTERLINE LOAD FACTOR @ 1/200 KITCHEN,COMMERCIAL DIVISION r1-EQUIPMENT (� O_ >� <br /> 7.THE GENERAL CONTRACTOR AND SUBCONTRACTORS GL OCCUPANT LOAD=4 COMPUTERS/DATA •• Ec.TO RUN col4DwnFREQuweO er LOCAL MUNICIPPLtt v In J a > <br /> SHALL TURN OVER ALL WRITTEN OPERATING INSTRUCTIONS ^` O <br /> AND WARRANTIES FOR EQUIPMENT TO THE OWNER AT THE MASTER MATERIAL SCHEDULE REFERENCE STORAGE AREA TELECOMMUNICATIONS EQUIPMENT •• W O m J <br /> VIDEC EQUIPMENT •• X <br /> COMPLETION OF WORK. GROSS AREA=733 S.F. KITCHEN EQUIPMENT • • K Z d m In <br /> DO EQUIPMENT SCHEDULE REFERENCE LOAD FACTOR @ 1/300 ACCESSORY STORAGE 0 N� _ Z. <br /> 8.ALL WORK PERFORMED BY THE CONTRACTOR AND - OCCUPANT LOAD=3 DIVISION 12-FURNISHINGS O N O O O <br /> SUBCONTRACTORS,INCLUDING MATERIALS AND LABOR ewayXO ART PACKAGE REFERENCE 000 O <br /> SHALL BE GUARANTEED IN WRITING FOR A PERIOD OF ONEakeout _i�ry BASEMENT LEVEL SEATING • • <br /> YEAR FROM DATE OF ACCEPTANCE BY DOMINO'S. WALL ASSEMBLY TYPE REFERENCE GROSS AREA=1104 S.F. MISCELLANEOUS DECOR ITEMS •• <br /> ISSUED FOR PERMIT: <br /> 9.THE GENERAL CONTRACTOR AND SUBCONTRACTORS,AT 0000 CABINET SCHEDULE REFERENCE RESTROOM AREA DIVISIONIS-SPECIALCONSTRUCTION 08.05.2021 <br /> THE COMPLETION OF THEIR WORK,SHALL LEAVE THE SITE ��- GROSS AREA=57 S.F. NO WORK REQUIRED UNDER THIS SECTION <br /> CLEAN AND FREE OF DEBRIS RELATED TO THEIR WORK,AND N-oo FURNITURE SCHEDULE REFERENCE <br /> THE STORE FINISHED TO PASS HEALTH INSPECTIONS AND TOTAL OCCUPANT LOAD=11 DIVISION 14-CONVEYING SYSTEMS <br /> MADE READY TO COMMENCE WITH THE BUSINESS OF FOODI ,��",��,�, NO WORK REQUIRED UNDER THIS SECTION <br /> PREPARATION. ELEVATION REFERENCE EXITS: <br /> o.o CUSTOMER AREA=1 DIVISION 1s-MECHANICPLPND PLUMBING <br /> 10.THE USE OF BRAND NAMES,CATALOGUE NUMBERS OR ^� TOTAL EXITS=1 WATER SUPPLY REV:DATE: DESCRIPTION: <br /> NAMES OF MANUFACTURERS IS SOLELY FOR THE PURPOSE qp_ DAMPERS •• H <br /> OF ESTABLISHING THE TYPE AND QUALITY THAT WILL BE 4 PROJECT LOCATION r ENLARGED DETAIL REFERENCE 11 PERSONS IN THIS SPACE X.20"/PERSON=2.2 INCHES DIFFUSER/GRIUES •• H <br /> ACCEPTABLE. UNLESS SPECIFICALLY PROHIBITED IN THE 1801 N BROADWAY AVE MIN.REQ'D H.Ogc.HEATING ANo coouNG UNTs •• <br /> SPECIFICATIONS,SUBSTITUTION WILL BE PERMITTED AFTER EVERETT,WA 98201 EXIT WIDTH PROVIDED=68 INCHES PROVIDED H.VAC.DUCTWORK •• H <br /> SUBMITTAL TO AND WRITTEN APPROVAL BY DOMINO'S. Q REVISION TAG EXHAUST FANS,U IUTY SETS AND DUCTWORK •• <br /> TOILETS: LIVATOHYFIXTURESPNDWATERHEATER •• <br /> 11. IT IS RECOMMENDED THAT THE CONTRACTOR ACQUIRE �, TOTAL NUMBER OF TOILET FACILITIES=1 PROVIDED SANITARY • <br /> THE DESIGN AND EQUIPMENT BROCHURES FROM DOMINO'S I REVISION CLOUD SUPPLY,VENT,WASTE PIPING •• SHEET NAME: <br /> p KITCHEN EQUIPMENT UTIUTY CONNECTIONS •• PH FINAL CONNECTIONS BY EACH TRADE SUBCONTRACTOREQUIPMENT&SUPPLY FOR REFERENCE WITH THESE Thai Mana in •• 0 FIRE PROTECTION SYSTEM(SPRINKLERI(ASREQ • s <br /> DOCUMENTS. �• FIRE PROTECTION SYSTEM IAS REO.) • FP <br /> qt� <br /> M ' EXHAUST HOOD MAKE-UP AIR(PS REO) • • H <br /> 12.GC IS RESPONSIBLE FOR MEANS AND METHODS FORT - - COVER SHEET <br /> INSTALLATION OF WORK INDICATED ON THESE DRAWINGS. IRA '�� MWIL W. M.. DlwsloN ls-ELEcmICAL <br /> 13. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO �'' -� INTERIOR AND EXTERIOR ucHT FlxruREs •• E <br /> PROVIDE ADDITIONAL DESIGN/BUILD INFORMATION,WHICH ELECTRI EMERGENCY ucenNc •• E <br /> MAY BE REQUIRED BY LOCAL CODE AUTHORITIES,WHICH ELECTRIC FOR TE rs •• E SHEET NUMBER: <br /> CONDUIT FOR TELEPHONE/DATA WIRES • • E IF REQUIRED BV LOCAL MUNICIPALITY �\ <br /> MEETS THE DESIGN CRITERIA IN THESE DOCUMENTS. 1 VICINITY MAP FIRE ALARM(AS REQ) •• FP /� ,0 <br /> KITCHEN EQUIPMENT UTILITY CONNECTIONS •• E,P,H,FP,G.C. FINAL CONNECTIONS BY EACH TRADE SUB-CONTRACTOR \(`/-p-I <br /> NOT TO SCALE <br /> COPYRIGHT 2021 <br />