My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2503 MADISON ST 2023-09-26
>
Address Records
>
MADISON ST
>
2503
>
2503 MADISON ST 2023-09-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2023 2:04:40 PM
Creation date
9/8/2023 11:46:35 AM
Metadata
Fields
Template:
Address Document
Street Name
MADISON ST
Street Number
2503
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VERETT <br />0 <br />Permit Inspections <br />City of Everett <br />3/28/2022 <br />3/28/2022 <br />PLUMB 03-ROUGH <br />JASON <br />RESCHEDULE <br />eTRAKiT Inspection Request <br />IN <br />MORRISSEY <br />ONLINE <br />Notes: <br />3/28/2022 8:09 AM John Barrett <br />Lock box on unit 3 - code is 6474 <br />Contact Name: John Barrett <br />Site Address: 2503 MADISON AVE #1,2,3,4 <br />Phone:2063004081 <br />e-Mail: jbarrett3@hotmail.com <br />(3/28/2022 8:25 AM JJM) <br />- Reschduled from 3/29/22 to 3/28/22 due to other cancelations. <br />3/28/2022 <br />3/28/2022 <br />PLUMB 03-ROUGH <br />JASON <br />CORRECTION <br />IN <br />MORRISSEY <br />REQUIRED <br />Notes: <br />Units 1&3 ( newly remodeled ) <br />- Obtain mechanical permit to reconnect kitchen hood exhausts to ducting that terminates at the exterior of the building with proper backdraft damper <br />per IMC and IRC. <br />*** If you want to use the existing new ductless hoods then you will need to provide separate exhaust fans in kitchen area of at least 100 CFM ducted to <br />the exterior per IMC and IRC. <br />M1505.4.4.1 Local Exhaust <br />Bathrooms, toilet rooms, and kitchens shall include a local exhaust system. Such local exhaust systems shall have the capacity to exhaust the minimum <br />airflow rate in accordance with Table M1505.4.4(1). Fans required by this section shall be provided with controls that enable manual override or <br />automatic occupancy sensor, humidity sensor or pollutant sensor controls. An %34on/off%34 switch shall meet this requirement for manual controls. <br />Manual fan controls shall be readily accessible in the room served by the fan. <br />M1501.1 Outdoor Discharge <br />The air removed by every mechanical exhaust system shall be discharged to the outdoors in accordance with Section M1504.3. Air shall not be <br />exhausted into an attic, soffit, ridge vent or crawl space. <br />3/28/2022 <br />3/28/2022 <br />PLUMB 07-FINAL <br />JASON <br />CORRECTION <br />MORRISSEY <br />REQUIRED <br />Notes: <br />- Unit 3 corrections: <br />1.) Caulk toilets and shower trim. Per UPC 402.2 Joints <br />2.) Secure shower head so it doesn't move around. Add extra screws to support fitting in wall. Per UPC 609.1. <br />3.) Add hammer arrester to DW stop. Per UPC 609.10. <br />4.) Reset DW so that it's level. Currently unit is tilted back at extreme angle. Center DW in opening for proper function of door. Per UPC 402.5 and <br />402.8. <br />- Unit 1 corrections: <br />1.) Add hammer arrester to DW stop. <br />2.) Reset DW so that it's level. Currently unit is tilted back at extreme angle. Center DW in opening for proper function of door. <br />3.) Caulk toilets and shower trim. <br />I <br />Printed: Tuesday, 06 June, 2023 2 of 4 rk <br />SUPERION <br />
The URL can be used to link to this page
Your browser does not support the video tag.