My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3308 ROCKEFELLER AVE 2023-09-26
>
Address Records
>
ROCKEFELLER AVE
>
3308
>
3308 ROCKEFELLER AVE 2023-09-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2023 3:05:29 PM
Creation date
9/11/2023 8:03:29 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3308
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> REVISION REPLY TO LETTER DATED June 17' 2020 <br /> July 20,2020 <br /> Owner: 3308 ROCKEFELLER AVE LLC pave <br /> Job Address: 3308 Rockefeller AvePlan Check No: B2005-035 ,„.eD <br /> ` AUG _ <br /> 3 2020 <br /> C/Ty <br /> Permit s6VERET <br /> RE: Building Permit Review Letter r/,ces <br /> 1. When creating a new dwelling unit,all provisions of the code in affect at the time of application <br /> apply to the new dwelling.Openings less than 3 feet from the property line are not allowed.The <br /> windows in the Dining Room and Kitchen are not allowed. Provide an alternate location for the <br /> required windows in the Dining Room, Kitchen and Living Room per section R303 IRC. <br /> R302.1 Exterior Walls.Construction, projections,openings and penetrations of exterior walls of <br /> dwellings and accessory buildings shall comply with tablerR302.1(1);or dwellings equipped <br /> throughout with an automatic sprinkler system installed in accordance with Section P2904 shall <br /> comply with table R302.1 (2). <br /> Attached new survey shows correction in property set back line at 3ft. Existing Basement windows <br /> are conforming. REVISED SHEET 1(SITE PLAN)&SHEET 2 (SURVEY) <br /> 2. One-hour fire-resistance rated construction is required between dwelling units.Where floor <br /> assemblies are required to be fire-resistance rated by Section R302.3,the supporting construction of <br /> such assemblies shall have an equal or greater fire-resistance rating. The reference on the plans to <br /> the assembly from the Gypsum Association (WP 3242), is for a wall not a floor. Provide details and/ <br /> or section drawings for all fire-rated assemblies specific to this structure. Including the supporting <br /> structure(s). <br /> REVISED SHEET 4 <br /> 3. Provide framing plan for the floor area where the stairs to the basement will be removed.Show that <br /> all joists are provided with bearing. REVISED NEW SHEET 4& 10 <br /> 4. Update Energy Code references to 2015 WSEC on all sheets. REVISED SHEET 4&8 <br /> 5. Please change description of the work on the site plan from"Proposed 840 SF Basement Remodel& <br /> ADU",to reflect actual scope of work,which is converting a SFR into a Duplex. <br /> REVISED SHEET 1 <br /> 6. Provide all four elevations and section drawings for the proposed Duplex without shading. (When <br /> drawings are scanned for records,shading comes out black and obliterates any details shown on the <br /> drawing.) REVISED SHEET 6 <br /> Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.