My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4201 RUCKER AVE COMMUNITY HEALTH CENTER 2023-09-11
>
Address Records
>
RUCKER AVE
>
4201
>
COMMUNITY HEALTH CENTER
>
4201 RUCKER AVE COMMUNITY HEALTH CENTER 2023-09-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2023 12:15:53 PM
Creation date
9/11/2023 10:26:28 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
4201
Tenant Name
COMMUNITY HEALTH CENTER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FEBCO 850U DOUBLE CHECK <br />PIP COCKS TO BE VALVE/BACKFLOW <br />UPRIGHT AND PREVENTION ASSEMBLY <br />EASILY ACCESSIBLE <br />FINISH GRADE <br />II III=III—III a III III—III—III_II <br />—I I I —III —I — <br />I BRA55 NIPPLE (SIZE AS \i <br />—III—I11I i` <br />2E I — REQUIRED) <br />=1III III=III Z <br />;IIIII111 IIIIIII - z <br />—I FOf C4 <br />GTITE #25—TA <br />CONCRETE VAULT W/ OD .. <br />LOCKING STEEL ' <br />HATCHES, MAINTAIN 6" d. - <br />CLEARANCE FOR GROUT OPENINGS (TYP)AL L' <br />ALL COMPONENTS AND <br />EDGES OF VAULT. WRAP ES WITH 40 MIL PVC <br />AAT GROUTED ROUTED OPENINGS (TYP.) <br />BRASS PIPE FROM , <br />GATE VALVE _ BRASS PIPE TO MASTER VALVE <br />lei <br />6" COMPACTED OF 5/8" <br />CRUSHED ROCK BASE _ <br />NOTE: <br />ADJUST DETAIL AS NEEDED TO <br />PLACE VALVE BOXES, MAINLINE, <br />& LATERAL LINES IN PLANTING <br />BEDS ON STRUCTURE. IN LIEU <br />OF FARM FENCE POST, USE <br />HARCO QUICK COUPLER ANCHOR <br />SCH 80-90 ELL <br />SCH 80 NIPPLE <br />SCH 80 PVC TEE <br />PVC MAINLINE <br />SIZE ON PLAN <br />18" MIN. <br />1/3 CU YD OF 3/8" WASHED ROCK AT BOTH <br />ENDS OF VAULT UNDER WEEP HOLE <br />DOUBLE CHECK VALVE <br />10" ROUND BOX W/ LOCKING COVER. <br />EXTEND AS NECESSARY <br />FINISH GRADE <br />QUICK —COUPLING VALVE <br />6" DEPTH BACKFILL BOX <br />WITH 3/8" WASHED ROCK <br />BRICK (1 OF 2, TYP.) <br />1"X6" SCH 80 NIPPLE <br />1" SCH 80 STREET 90 <br />1" SCH 80 TT 90 <br />1"X3" SCH 80 NIPPLE <br />1"i SCH 80 NIPPLE <br />3• STEEL FARM FENCE <br />POST W/3 EA SS CLAMPS <br />COMPACTED SUBGRADE <br />3 QUICK COUPLING VALVE <br />oeral - No scauE <br />DETAIL - NO scAlE <br />WATERTIGHT SI <br />(SEE SPECS) <br />MASTER VALVE <br />SPARE WIRE (1 • • BRASS�.% <br />EACH 4 ZONES PER <br />(2 PLACES) <br />BRASS <br />PIPE <br />�` ■ <br />• DCVA <br />�,!III,III11!�!IIIUI,�!I <br />MASTER VALVE <br />NOTES: <br />1.. USE TEFLON TAPE ON ALL <br />THREADED FITTINGS. <br />MAIL - No <br />CLEAN, COMPACTED, <br />SUITABLE NATIVE <br />BACKFILL. <br />14 GA. BARE <br />COPPER WIRE <br />F3i1:LS7I_�1�IL1��I.I� <br />14 GA. BARE COPPER <br />WIRE <br />SCH 40 PVC MAINLINE. <br />BUNDLE CONTROLLER <br />WIRES BELOW MAINLINE ON <br />OPPOSITE SIDE FROM <br />SWING JOINTS IN A <br />SNAKELIKE FASHION COVER <br />WITH 2" OF CLEAN, <br />SUITABLE NATIVE BACKFILL <br />PRIOR TO MAINLINE <br />INSTALLATION. <br />NOTES: <br />1. TAPE WIRES TOGETHER <br />EVERY 10% BUT DO NOT <br />TAPE BUNDLED WIRES TO <br />MAINLINE. <br />2. WHEN PLACING PIPING ON <br />DECKING, PLACE PIPING IN <br />A SLEEVE & DIRECTLY ON <br />DECKING BELOW PAVERS. <br />IRRIGATION TRENCHING <br />J oETni� - No scs�E <br />NOTE: <br />ADJUST DETAIL AS NEEDED TO PLACE <br />VALVE BOXES, MAINLINE, & LATERAL LINES <br />IN PLANTING BEDS ON STRUCTURE <br />BRASS/BRONZE ANGLE GATE <br />VALVE RED/WHITEOR EQUAL <br />SAME SIZE AS CONTROL VALVE <br />FINISH GRADE—\ <br />SCH 80 PVC CLOSE <br />NIPPLE, TIP. <br />SCH. 80 ST90 <br />SCH. 80 PVC SS <br />T.O.E. NIPPLE. <br />LENGTH AS <br />REQUIRED <br />PAVING BRICK <br />SCH. 80 BUSHING <br />SXSXBUSH <br />SCH. 40 PVC MAIN <br />LOOPED & ZIP TIED WIRE WITH 48" COILED <br />EXTRA WIRE (DIFFERENT COLOR) INSTALL <br />ONE EXTRA COIL PER VALVE BOX <br />SPECIFIED VAULT FLUSH <br />WITH FINISHED GRADE <br />oil- EXOTE <br />ELECTRIC R <br />CONTROL VALVE <br />I'SCH :, PVC UNION <br />BO ST90 <br />AS REQUIRED <br />:0 PVC SS <br />AS REQUIRED <br />•'rT.O.E. NIPPLE LENGTH <br />me s <br />AUTOMATIC CONTROL VALVECONTROL VALVE <br />48" COILED EXTRA WIRE <br />(DIFFERENT COLOR) <br />INSTALL ONE .EXTRA COIL <br />PER VALVE #OX _ No SCALE <br />3/8" WASHED ROCK <br />SUMP TYP. <br />Design Two Four/Two Six <br />µEE835 N, WA COURT SE <br />RENTON, WA 98059-8839 <br />ph.(425) 881-2426 <br />CIL (206) 335-7719 <br />w.design2426.com. <br />and aRArWmNrt Irr VsA 111611A-ANIn4fitll IXvgi.OnAuNm Xn <br />COMMUNITY <br />HEALTH CENTEI <br />OF SNOHOMISF <br />COUNTY— <br />EVERETT <br />CENTRAL <br />4205 RUCKER AVENUE <br />EVERETT, WA 98203 <br />VLAD OUSTIMOVITCH <br />4109 SW ORCHARD $TREE <br />SEATTLE, WA 9813E <br />Design Teem <br />Design <br />JA <br />Drown <br />JA <br />Revie,one <br />Ni <br />1 7/13117 Land Use Revisions'. <br />Key Plan <br />AS DESIGNED DRA <br />IRRIGATION <br />DETAILS <br />L-1.2 <br />2009 IX91GN 2426 INC, <br />
The URL can be used to link to this page
Your browser does not support the video tag.