Laserfiche WebLink
11317 2 Means.of.Egress YES NO <br />R311.2 Door must be side -hinged with min. width of 32 inches between face of door and stop. Height not less than 78 Inches. <br />R330.4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable with one hand <br />and shall not require tight grasping, pinching or twisting of the wrist (lever -type). <br />R330.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry 13 <br />without use of key, tool or special knowledge. <br />A311,7 Stairways I N/A YES NO <br />R311.7.5.1 Riser Height: Max riser height shall be 7 % inches (8 inches in structures built prior to July 1, 2004) <br />R311.7.5.2 Tread Depth: Min. tread depth shall be in 10Inches (9 inches in structures built prior to July 1, 2004) CI0 <br />R330.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to multiple <br />risers. Handrails shall be installed in accordance with R311.7.8.1— R311.7.8.4 <br />R330.8 Grab Bars in Bathrooms N/A YES NO <br />Grab bars shall be installed for all water closets (toilets), bathtubs and showers according to R330.8. <br />Water Closets (toilet) shall have grab bars Installed on both sides according to R330.8.3 <br />Bathtubs shall have two vertical and three horizontal grab bars installed according to R330.8.4 <br />Shower stalls have two vertical and horizontal grab bars mounted on all sides of shower according to R330.8.5 <br />Shower stalls must be minimum size of 30 inches deep by 48 inches long (R330.11) <br />'k-lp'Voa�- W i �L- i3E- Ewv" 0r hit M - <br />Implementation Date: 2021 February 01 <br />Updated: 2021 February <br />