My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7601 EVERGREEN WAY SAFEWAY FUEL STATION 2023-09-11
>
Address Records
>
EVERGREEN WAY
>
7601
>
SAFEWAY FUEL STATION
>
7601 EVERGREEN WAY SAFEWAY FUEL STATION 2023-09-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2023 2:48:30 PM
Creation date
9/11/2023 2:36:52 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7601
Tenant Name
SAFEWAY FUEL STATION
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES: <br />1. ALL FILL & STAGE I VAPOR RISERS SHALL BE ELECTRICALLY GROUNDED TO PROMOTE THE RELAXATION OF STATIC CHARGE. <br />2. THE BONDING & GROUNDING FOR STATIC ELECTRICITY PROTECTION SHALL BE IN COMPLIANCE PER ALL APPLICABLE FEDERAL, STATE, & <br />LOCAL CODES INCLUDING NFPA 30, FLAMMABLE & COMBUSTIBLE LIQUIDS CODE, NFPA 77, RECOMMENDED PRACTICE ON STATIC <br />ELECTRICITY, NFPA 70, NATIONAL ELECTRIC CODE, & THE CALIFORNIA CODE OF REGULATIONS, SUBCHAPTER 15, PETROLEUM SAFETY <br />ORDERS- REFINING, TRANSPORTATION & HANDLING, ARTICLE 5, FIRE & EXPLOSIONS. <br />3. PER SECTION 6.4.1.3 OF NFPA 77, THE MEASURED TOTAL RESISTANCE IN THE GROUND PATH TO EARTH SHALL BE LESS THAN 1 MEGAOHM <br />WHICH IS CONSIDERED ADEQUATE FOR RELAXATION OF STATIC CHARGE. THE MAXIMUM ALLOWABLE GROUNDED PATH TO EARTH <br />RESISTANCE FOR STATIC ELECTRICITY GROUNDING APPLICATIONS SHALL NOT EXCEED 100,000 OHMS. <br />4. PER SECTION 6.4.1.3 OF NFPA 77, THE RESISTANCE IN METALLIC BONDING & OR GROUNDING SYSTEMS SHALL BE LESS THAN 10 OHMS. <br />RESISTANCE HIGHER THAN 10 OHMS INDICATES INADEQUATE CONNECTIONS. <br />5. A GROUNDING SYSTEM PER NEC CODE FOR CURRENT CARRYING CONDUCTORS SHALL BE CONSIDERED MORE THAN ADEQUATE FOR A <br />STATIC ELECTRICITY GROUNDING SYSTEM. <br />6. PER THE NFPA 30, SECTION 4.5.3.4 ALL PARTS OF THE FILL PIPE ASSEMBLY, INCLUDING THE DROP TUBE, SHALL FORM A CONTINUOUS <br />ELECTRICALLY CONDUCTIVE PATH. <br />GROUND WIRE TO <br />ADDITIONAL SPILL BUCKET OR <br />GROUND ROD, PER DETAIL A <br />TANK#3: 10,000 <br />GALLONS DIESEL <br />GROUNDING ROD CAN BE LOCATED ANYWHERE ON <br />SITE, AS LONG AS IT IS IN NATIVE SOIL AND <br />ACCESSIBLE VIA THE SPECIFIED MANHOLE DETAIL C <br />4" FRP RISERS <br />FILL AND VAPOR BONDING <br />1 SCALE: 1"= 1'-0" <br />7. THE MINIMUM WIRE SIZE FOR BONDING & GROUNDING SHALL BE COPPER AWG #4. <br />8. A 01/2" BY 10' LONG COPPER CLAD STEEL GROUND ROD SHALL BE DRIVEN INTO NATIVE SOIL ONLY. PLACING THE GROUND ROD INTO TANK <br />PIT PEA GRAVEL SHALL NOT BE PERMITTED UNDER ANY CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR CLEARING ANY <br />UNDERGROUND UTILITIES PRIOR TO INSTALLATION OF THE GROUND ROD. <br />9. THE GROUND ROD TO GROUND WIRE CONNECTION SHALL BE ACCESSIBLE THROUGH A H-20 RATED 12" DIAMETER MINIMUM ACCESS COVER <br />TO ASSIST INSPECTION, MAINTENANCE & TESTING. THE SCREW TYPE GROUND ROD CLAMP SHALL BE UL LISTED FOR DIRECT BURIAL. <br />10. GROUND WIRE TO BE ONE CONTINUOUS LOOP FROM GROUND ROD TO LAST TANK RISER. <br />11, ALL STAINLESS STEEL HARDWARE MUST BE USED TO FASTEN THE GROUNDING COMPONENTS, <br />NOTE: ELECTRICAL CONDUIT, FUELING SYSTEM HARDWARE OR THE STATION ELECTRICAL GROUNDING SYSTEM SHALL NOT BE USED FOR <br />GROUNDING OR BONDING FILL & VAPOR RISERS. <br />GROUNDING ROD <br />SPILL BUCKET <br />ATTACH GROUND <br />WIRE TO SPILL <br />BUCKET DESIGNATED <br />GROUND <br />CONNECTION, TYP. <br />FILL AND STAGE TANK #1 :20,000 <br />3 SPILL BUCKETS — — GALLONS REGULAR <br />(TYPICAL 2 PER TANK) <br />O <br />TANK #2: 10,000 <br />GALLONS PREMIUM <br />TESTING: <br />1. CAUTION: AVOID CONNECTING ANY ELECTRICAL TEST LEAD TO THE FILL OR VAPOR RISER IN A <br />MANNER THAT WOULD POTENTIALLY PRODUCE STATIC DISCHARGE OR SPARKS OF ANY KIND. <br />2. THE FILL & VAPOR RISERS SHALL BE TESTED AFTER INSTALLATION & PERIODICALLY TO VERIFY <br />BONDING & GROUNDING COMPETENCY. <br />3. THE MAXIMUM RESISTANCE FROM ANY FILL OR VAPOR ADAPTER TO THE BODY OF THE GROUND <br />ROD SHALL NOT EXCEED 10 OHMS. <br />4. THE TEST LEAD MUST BE CONNECTED TO THE GROUND ROD BODY, NOT THE GROUND ROD CLAMP <br />OR WIRING. <br />5. THE NEC MAXIMUM GROUND PATH RESISTANCE FOR CURRENT CARRYING APPLICATIONS IS 25 <br />OHMS. HOWEVER, GROUND ROD TO EARTH RESISTANCE UP THE 100 OHMS SHALL BE <br />ACCEPTABLE FOR STATIC ELECTRICITY PROTECTION OF THE FILL & VAPOR RISERS. <br />16 0 8 16 <br />GROUNDING PLAN <br />l „ / SCALE: 1/8" OF 1'-0" <br />LOOP <br />C GROUND ROD <br />SCALE: 1" = 1'-D" <br />REVISIONS <br />LL <br />0 <br />w <br />N <br />y <br />r <br />Z <br />} <br />Q M <br />3 <br />Q <br />� W � <br />W <br />w <br />LL o > <br />Q w W w <br />Q <br />� <br />J <br />3 <br />LU <br />0 <br />W <br />z <br />LL <br />z <br />Z <br />Q <br />Z <br />z <br />Q <br />H <br />DIAMOND Z ENGINEERING, INC. <br />W70 STATE ROAD <br />CLEVELAND, OH 44134 <br />PHONE: 440d 24 Wl <br />SCALE: <br />DATE: <br />AS NOTED <br />02/24/2023 <br />DRAWN BY: <br />PROJECTNO.: <br />OFF <br />WA-4226 <br />DRAWING NO. <br />T-4 <br />