My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7601 EVERGREEN WAY SAFEWAY FUEL STATION 2023-09-11
>
Address Records
>
EVERGREEN WAY
>
7601
>
SAFEWAY FUEL STATION
>
7601 EVERGREEN WAY SAFEWAY FUEL STATION 2023-09-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2023 2:48:30 PM
Creation date
9/11/2023 2:36:52 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7601
Tenant Name
SAFEWAY FUEL STATION
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EVERGREEN WAY <br />=ROPEINE �� <br />MAXIMUM 100' <br />ESTOP RADIUS <br />(1) 1-1/2" CONDUIT <br />(1) 1" CONDUIT <br />EXISTING 6" CORRUGATED (1) 3/4 CONDUIT <br />POLYETHYLENE STORM PER RECORD PLANS <br />PIPING PER RECORD <br />PLANS 1 2 10 11 (TVP.) <br />g 3+0 DISPENSER A <br />21 5-2 3+1 DISPENSER / w , <br />7 ASPHALT (TYP. OF 4) D-, <br />(TYP. OF 14) 2 <br />- - - - - - - - - - - - - - - - - - <br />0 <br />P P P-P-P-P-P P-P-P-P-P P P- P-P-P-P--P-P-P-P-P-P-P- <br />R-R-R-R-R-R-R-R-R-R-R R R- R-R-R R -R�2� _R R-R�1 <br />r-R-R-R-R R-R-R-R-R- ,n <br />I nni I n' <br />SO <br />E <br />12 0� rc G E� 4 rcno 1 Q� 8 rca 1 <br />III II = CONCRETE z <br />�D -D -D �n �n <br />TANK #3: 10,000 >> �yi P ^�P a I' I I I 1 19 <br />GALLONS DIESEL 27 I6II I 1 -- i 23 23 �I O 22 <br />`! n° o.stm ...... <br />xn° n I <br />/ y I X <br />I I � <br />>>I - I I I I I C I I I / I I EXISTING <br />4 I I �nD rcn SAFEWAY \ <br />I I I KIOSK <br />�l <br />I I II I I 501 502 503 <br />3 5 8 I Ifl J <br />504 505 508 <br />STP SUMP 14 15 I I I I ° <br />(TYP. OF 3) .--. \ d� l JJ <br />*ALRE <br />I I ���rvEl � 5 6(TYP. 3+0 DISPENSER EXISTINGALARM AND(TVP. OF 2) 8 9 10 ,4 ACKNOWLEDGEMENT <br />SWITCH <br />27 W❑ 15 16 26 (TYP. ALL <br />DISPENSERS) <br />TANK RE ULAR [. sa, E-STOP 18 <br />GALLONS REGULAR <br />\ EXISTING OIL/WATER EXISTING 6" <br />SEPARATOR PER PVC SANITARY <br />RECORD PLANS LINE PER <br />RECORD <br />PLANS <br />\ EXISTING CATCH J <br />BASIN PER RECORD <br />PLANS <br />II��II�IIIl ll311� �^Mq� <br />1- COPPER WATERLIN\ <br />PER RECORD PLANS <br />A \ <br />3+0 DISPENSER <br />I3 <br />L EXISTING FUEL <br />CANOPY <br />MINIMUM 20' <br />E-STOP RADIUS <br />-P-p-p-p -p- <br />-J3= <br />j <br />IIl <br />wIl1 <br />1 I <br />II <br />rcn <br />I11 <br />EXISTING <br />STORM PIPING <br />11l <br />PER RECORD <br />1 <br />11° <br />PLANS <br />rcnl <br />II° <br />ono <br />JJ <br />EXISTING 4" PVC <br />CANOPY DRAIN <br />PER RECORD <br />PLANS (TYP. OF S) <br />A^ 3+0 DIS TENSER <br />CONSTRUCTION NOTES: O SEE M-1FOR MATERIALS <br />DEMOLITION <br />1. EXCAVATE FOR PIPING REMOVAL. MINIMIZE DISTURBED AREA, BUT PROVIDE ENOUGH SPACE TO INSTALL PIPING PER <br />PLAN AND ADHERE TO THE 4' RULE PER ALBERTSONS SPECIFICATIONS. INSTALL 6' HIGH CHAIN LINK FENCE PANELS <br />AROUND DEMOLITION LIMITS. <br />2. REMOVE ALL EXISTING DOUBLE WALL FLEX PRODUCT PIPING, AND EXISTING VAPOR RECOVERY PIPING FROM TANKS <br />TO THE EIGHT (8) DISPENSERS. CHASE PIPE TO REMAIN WITH ENDS CAPPED. VAPOR RECOVERY SHALL BE CAPPED <br />AND ABANDONED IF NOT UNCOVERED. <br />TANK TOP: <br />3. REMOVE EXISTING TANK STP SUMPS AND INSTALL THREE (3) NEW BRAVO FRP TANK STP SUMPS. <br />4. REMOVE EXISTING DUAL POINT FILL/STAGE I MANHOLES AND SUMPS, AND INSTALL SIX (6) NEW OPW EDGE SERIES <br />DOUBLE WALL 5 GALLON SPILL CONTAINERS: THREE (3) FOR THE FILL CONNECTIONS, AND THREE (3) FOR THE STAGE <br />I VAPOR CONNECTIONS. INSTALL FLAPPER VALVE OVERFILL PREVENTION DEVICES IN THE FILL RISERS. <br />5. INSTALL NEW RE PETRO VARIABLE SPEED PUMPS WITH NEW FLEX CONNECTORS AND BALL VALVES. <br />6. INSTALL THREE (3) NEW EMCO WHEATON COMPOSITE STP MANWAYS. <br />7. INSTALL TWO (2) NEW 18" CAST IRON MANHOLES WITH COMPOSITE LIDS FOR TANK INTERSTITIAL MONITORS. <br />DISPENSERS: <br />8. REMOVE EXISTING DISPENSERS AND INSTALL EIGHT (8) NEW DISPENSERS. DISPENSER INSTALLATION AND STARTUP <br />SHALL BE UNDER SEPARATE CONTRACT. <br />9. REMOVE EXISTING DISPENSER SUMPS. INSTALL EIGHT (8) NEW BRAVO FRP DISPENSER SUMPS. INSTALL NEW <br />STABILIZER BARS, SHEAR VALVES, AND FLEX CONNECTORS FOR EACH DISPENSER. <br />PIPINGNENTS: <br />10. INSTALL NEW 2" FRP SINGLE WALL STAGE II VAPOR RECOVERY PIPING FROM STAGE I VAPOR SPILL CONTAINER TO <br />DISPENSER SUMPS. INSTALL 3" FRP SINGLE WALL VAPOR RECOVERY PIPING WHERE SHOWN ON PLAN. <br />11. INSTALL NEW DOUBLE WALL FRP PRODUCT PIPING, 2" INSIDE 3" FROM NEW STP SUMPS TO DISPENSERS. <br />12. REMOVE EXISTING 2" AND 3" VENT LINE AND INSTALL THREE (3) NEW 2" FRP VENT LINES, ONE FOR EACH TANK <br />COMPARTMENT. <br />13. INSTALL (3) NEW 2" VENT RISERS AND VENT CAPS. <br />ELECTRICAL: <br />14. EXISTING ELECTRICAL CONDUITS SHALL BE REUSED EXCEPT WHERE NEW SUMPS ARE INSTALLED. THE EXISTING <br />CONDUITS SHALL BE CUT BACK WITHIN THE DEMOLITION LIMITS AND REPLACED. THE FIRST 2' OF EACH CONDUIT <br />BEYOND THE SUMP WALL EXTERIOR $HALL BE RMC BEFORE CONVERTING TO PVC. <br />15. EXISTING POWER WIRING AT TANKS AND DISPENSERS SHALL BE TESTED AND REUSED, OR REPLACED IF FOUND IN <br />POOR CONDITIONS. <br />16. REPLACE EXISTING DATA CABLE WITH CAT-6 CABLE. <br />17. REPLACE EXISTING TLS-350 TANK MONITOR WITH NEW TLS-0SOPLUS. REPLACE EXISTING SENSORS AND PROBES. <br />EXISTING INTRINSICALLY SAFE SENSOR WIRING SHALL REUSED. <br />18. ANY EXISTING E-STOP DISCONNECT SWITCHES TO REMAIN. <br />PAVEMENT: <br />19. BACKFILL EXCAVATION WITH PREVIOUSLY EXCAVATED MATERIALS ONLY IF MATERIAL IS ACCEPTABLE TO PIPING <br />MANUFACTURER. <br />20. INSTALL REBAR AND RESURFACE DRIVE SLAB AND TANK SLAB CONCRETE TO MATCH EXISTING. MANHOLES TO BE <br />SET WITH 2" CONCRETE CROWN AT 24' OFF EDGE. SEE SHEET T-1 AND T-3 FOR DETAILS. <br />21. INSTALL ASPHALT SURFACES TO MATCH EXISTING, WHERE AFFECTED. SEE SHEET T-3 FOR DETAILS. <br />22, INSTALL SELF -LEVELING JOINT SEALANT AT ALL CONSTRUCTION JOINTS. <br />POST INSTALLATION: <br />23. FOUR (4) FIRE EXTINGUISHERS TO REMAIN. VERIFY EXTINGUISHER TO HAVE A MINIMUM RATING OF 2A:20:6 C. FIRE <br />EXTINGUISHER IS LOCATED NOT MORE THAN 75 FEET FROM PUMPS, DISPENSERS OR STORAGE TANK FILL -PIPE <br />OPENINGS. <br />24. CLEAN UP THE SITE AND REMOVE ALL CONSTRUCTION DEBRIS, INCLUDING LOT SWEEPING OF AFFECTED AREAS. <br />25. COORDINATE ALL REQUIRED INSPECTIONS WITH JURISDICTION AUTHORITIES AND THIRD -PARTY INSPECTORS. <br />ISLANDS: <br />26. INSTALL EIGHT (8) NEW ISLANDS. <br />PRODUCT CHANGE: <br />27. CONVERT EXISTING PREMIUM COMPARTMENT TO DIESEL AND CONVERT EXISTING DIESEL COMPARTMENT TANK TO <br />PREMIUM. REPLACE FLOAT KITS AND UPDATE VEEDER-ROOT PROGRAMMING ACCORDINGLY. <br />MISCELLANEOUS NOTES: <br />1. OWNER DESIGN REQUIREMENTS SHALL BE FOLLOWED EVEN IF THEY EXCEED LOCAL AND STATE <br />REQUIREMENTS. <br />2. ALL LIGHTING IS EXISTING. NO INSTALLATION OF NEW LIGHTS OR MODIFICATIONS TO EXISTING <br />LIGHTS IS PART OF THIS PROJECT. <br />3. THE PROPOSED SCOPE OF WORK INVOLVES THE REPLACEMENT OF EXISTING FUEL SYSTEM <br />EQUIPMENT. NO ADDITIONAL ELECTRICAL LOADS SHALL BE ADDED. EXISTING BREAKERS AND WIRING <br />SHALL REMAIN AS IS. <br />4. EXISTING EMERGENCY STOPPER NEC 514.11 TO REMAIN. <br />5. SEAL -OFF FITTINGS TO BE INSTALLED AT TANKS AND DISPENSERS PER NEC 514.9. <br />TRENCH DRAIN 6. RECORD UTILITIES IN PROXIMITY OF WORK AREA SHOWN. CONTRACTOR SHALL LOCATE ALL <br />UNDERGROUND UTILITIES PRIOR TO EXCAVATION. <br />LEGEND: <br />-R -R - REGULAR GASOLINE PRODUCT PIPING <br />-P -P - PREMIUM PRODUCT PIPING <br />-D-D- DIESEL PRODUCT PIPING <br />- V - VENT PIPING <br />2" VAPOR RECOVERY PIPING <br />3" VAPOR RECOVERY PIPING <br />- - - EXISTING VAPOR RECOVERY PIPING <br />SLOPE ARROW <br />® DISPENSER FUELING POSITION NUMBER <br />EXISTING CATCH \ / <br />BASIN PER RECORD FRP PIPE SHALL HAVE A MINIMUM OF 4'OF STRAIGHT PIPE OUTSIDE OF SUMPS Z <br />PLANS BEFORE A DIRECTIONAL CHANGE PER ALBERTSONS SPECIFICATIONS <br />20 0 10 20 <br />, INCH =10 FEET <br />REVISIONS <br />rc <br />0 <br />W <br />m <br />} <br />NN <br />O1 °1 <br />W <br />w K <br />w <br />LL o > <br />N W W <br />�lQ^ <br />n <br />Q <br />3 <br />W <br />Lim <br />Q <br />W <br />D_ <br />a <br />1' <br />>0 <br />DIAMOND Z ENGINEERING, INC. <br />W70 STATE ROAD <br />CLEVELAND, OH 44134 <br />PHONE: 440d 24501 <br />SCALE: <br />DATE: <br />1"=10' <br />02/24/2023 <br />DRAWN BY: <br />PROJECT NO.: <br />ORE <br />WA-4226 <br />DRAWING NO. <br />C-2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.