Laserfiche WebLink
Lntertok <br />Total Quality. Assured. <br />TEST REPORT FOR WESTWOOD INVESTORS, LLC <br />Project No.: N8834.01-901-43 <br />Date:06/02/23 <br />22155 68th Avenue South <br />Kent, Washington 98032 <br />BASELINE <br />NOMINAL <br />ADJUSTED <br />BUILDING <br />BUILDING <br />NOMINAL <br />ADJUSTED <br />PRESSURE <br />PRESSURE <br />FLOW <br />FLOW <br />(Pa) <br />(Pa) <br />(cfm) <br />(cfm) <br />% ERROR <br />AVG. PRE- <br />BASELINE <br />-0.3 <br />- <br />- <br />- <br />- <br />50.1 <br />50.2 <br />1,730 <br />1,737 <br />-0.2 <br />55.0 <br />55.1 <br />1,853 <br />1,861 <br />0.0 <br />60.0 <br />60.1 <br />1,981 <br />1,990 <br />0.4 <br />INDUCED TEST <br />65.0 <br />65.2 <br />2,081 <br />2,091 <br />-0.4 <br />PRESSURES <br />70.2 <br />70.3 <br />2,222 <br />2,232 <br />0.6 <br />75.2 <br />75.3 <br />2,310 <br />2,321 <br />-0.4 <br />AVG. POST <br />BASELINE <br />0.0 <br />- <br />- <br />- <br />- <br />AIR LEAKAGE COEFFICIENT, C <br />103.8 <br />EXPONENT, n <br />0.720 <br />CORRELATION COEFFICIENT, r <br />0.99921 <br />EQLA' at 10 Pa (in') <br />160.0 <br />ELA2 at 4Pa (inZ) <br />79.9 <br />AIRFLOW at 75 Pa <br />2,323 <br />AIR LEAKAGE PER ENCLOSURE AREA <br />at 75 Pa, (cfm/ftZ) <br />MEAN <br />95% CONFIDENCE INTERVAL <br />LOWER <br />UPPER <br />0.255 <br />0.252 <br />0.257 <br />1. EQLA— Equivalent Leakage Area <br />2. ELA — Effective Leakage Area <br />Page 9 of 18 <br />