<br />SYMBOLS LEGEND
<br />PROJECT TEAM
<br />=
<br />OWNER
<br />ALL WORK, ALL EQUIPMENT,
<br />EXISTING DUCT WORK, GRILLS AND EXISTING UNITS
<br />ALL PARTS TO BE INSTALLED,
<br />WILL BE IN FULL COMPLINCE
<br />PORT OF EVERETT
<br />TENANT
<br />SOUND2
<br />1830 BICKFORDORD #111, AVEA
<br />SNOHOMISH. WA g82g0
<br />NEW SUPPLY AIR DUCT WORK, GRILLS AND NEW UNITS
<br />WITH ALL CODES BELOW.
<br />PROPERTY INFORMATION
<br />IVLVV f\ I Ur 11 F !FN LduI I VVVRr\ /YIVLJ VRILLJ
<br />NEW EXHAUST DUCT WORK, GRILLS AND FAN
<br />NEW ERV DUCT WORK, GRILLS AND UNITS
<br />2018 WS E C
<br />YY �.I
<br />2018 IMC
<br />2020 NEC
<br />ARCHITECTURAL
<br />CONCEPT ARCHITECTURE, L-C. P: (425) 377-8786
<br />2615 W. CASINO RD. SUITE 1A
<br />EVERETT, WA 98204 MREIMERS@CONCEPTARCHITECTURE.COM
<br />ADDRESS
<br />1710 W MARINE VIEW DR, EVERETT, WA 98201
<br />APN
<br />29051800400500
<br />SIZE
<br />1.02 AC.
<br />SUBDIVISION
<br />N/A
<br />MU
<br />ZONE
<br />FLEX DUCT WORK SUPPLY OR ETURN
<br />Zu Its Irl.
<br />PROJECT DESCRIPTION
<br />2018 IBC
<br />® UNIT SUPPLY AIR DUCT DROPS
<br />2018 UPC WORK TO BE DONE
<br />� UNIT RETURN AIR DUCT DROPS
<br />TENANT IMPROVEMENT FOR NEW BREWERY IN NEW TENANT SPACE.
<br />ALL EQUIPMENT WILL BE TESTED 1) INSTALL USED ROOF FAN WITH
<br />® SUPPLY AIR GRILLS
<br />WITH REPORT PER CODE GREASE DUCT FROM USED PIZZA
<br />CODES
<br />® SUPPLY AIR GRILLS
<br />OVEN TO ROOF FAN
<br />® SUPPLY AIR GRILLS
<br />ALL SUPPLY AIR GRILLS WILL AIR 2) FAN AND PIZZA OVEN USED
<br />FLOW TESTED AND ADJUSTED WITH PROVIDE BY OWNERSHIP
<br />BASED ON THE FOLLOWING CODES
<br />20181ntemational e
<br />SIDEWALL SUPPLY AIR GRILLS
<br />REPORT PER CODE 3) INSTALL ONE NEW GAS MAKEUP
<br />2018 Residential
<br />Residential Code
<br />2018 International Mechanical Cade
<br />RETURN AIR GRILLS
<br />AIR UNIT WITH DUCT WORK AND
<br />2018 Washington State Energy Code
<br />Washington
<br />2018 Unifomtional Fire Code
<br />2018 Uniform Plumbing Cade
<br />SIDEWALL RETURN AIR GRILLS
<br />ALL DUCT WORK WILL BE INSULATED GRILLS
<br />2020 National Electrical Code
<br />202009 Washington 1CC/ANSI A17.1 17.1Ameens
<br />TO CODE PER 2018 IMC 4) INSTALL GAS PIPE FROM METER
<br />Lu
<br />c
<br />® CJ.,.., ..,. L,.,, ..,.,mow
<br />TO PIZZA OVEN AND ROOF TOP
<br />wCo
<br />cq
<br />MAKEUP AIR UNIT
<br />>
<br />w
<br />250 CFM AT GRILLLU
<br />20X20 GRILL SIZE
<br />OCCUPANCYGROUP
<br />(A-2)
<br />CC
<br />G
<br />LU
<br />111
<br />t j
<br />-
<br />K
<br />FLOOR AREA
<br />2,947 S.F.
<br />FULLY SPRINKLERED
<br />YES
<br />OVERALL OCCUPANT LOAD
<br />120 OCC.
<br />CONSTRUCTION TYPE
<br />VB
<br />IZ V DUCTWORK SIZE
<br />U)
<br />LU
<br />CV
<br />HAND DAMPER TO ADJUST CFM
<br />LU
<br />0
<br />LFJ CEILING FAN
<br />Z
<br />F�11111- INLINE FAN
<br />0
<br />OT THERMOSTAT
<br />Z-1 NEW ZONE#
<br />ZD-1 NEW ZONE DAMPER WITH MOTOR
<br />R/D REDUCT EXISTING GRILL
<br />M MOVE EXISTING GRILLS, THERMOSTAT AND UNIT
<br />DUCT CONNECTION
<br />.. ■ ... MAINTENANCE SPACE
<br />S/D SMOKE DETECTOR
<br />F/S/D FIRE SMOKE DAMPER
<br />C/R/D CEILING RADIATION DAMPER
<br />DUCT SYSTEMS INSULATION SCHEDULE
<br />LOCATION OF DUCT
<br />DUCT SYSTEM TYPE
<br />DUCT CONFIGURATION
<br />INSULATION TYPE
<br />MINIMUM R-VALUE, INSULATION
<br />NOTES
<br />THICKNESS
<br />DUCT NOT WITHIN CONDITIONED SPACE
<br />SUPPLY, RETURN, EXHAUST, MIXED,
<br />OUTSIDEM, AND TRANSFER AIR DUCTS
<br />RECTANGULAR- EXPOSED
<br />RIGID BOARD
<br />R-7, 1 LAYER, 2INCH THICK
<br />RECTANGULAR -CONCEALED
<br />DUCT WRAP
<br />R-7, 1 LAYER, 3INCH THICK
<br />ROUND AND OVAL
<br />DUCT WRAP
<br />R-7, 1 LAYER, 3 INCH THICK
<br />SUPPLY, RETURN, EXHAUST,
<br />DUCT WITHIN CONDITIONED SPACE
<br />GENERATOR EXHAUST, RELIEF, AND
<br />RECTANGULAR -EXPOSED
<br />RIGID BOARD
<br />R-3.3, 1 INCH THICK
<br />TRANSFER AIR DUCTS
<br />RECTANGULAR -CONCEALED
<br />DUCT WRAP
<br />R-3.3, 1 LAYER, 1-1/2 INCH THICK
<br />ROUND AND OVAL
<br />DUCT WRAP
<br />R-3.3, 1 LAYER, 1-1/2 INCH THICK
<br />MIXED AND OUTSIDE AIR DUCTS
<br />RECTANGULAR -EXPOSED
<br />RIGID BOARD
<br />R-7, 1 LAYER, 2INCH THICK
<br />RECTANGULAR -CONCEALED
<br />DUCT WRAP
<br />R-7, 1 LAYER, 3INCH THICK
<br />ROUND AND OVAL
<br />DUCT WRAP
<br />R-7, 1 LAYER, 3 INCH THICK
<br />DUCTS AND PLENUMS WITHIN
<br />R-VALUE EQUAL TO BUILDING ENVELOPE,
<br />CONDITIONED SPACE FUNCTIONING AS
<br />ALL DUCT TYPES
<br />RECTANGULAR
<br />RIGID BOARD
<br />THICKNESS AS REQUIRED
<br />NOTE 1
<br />PART OF BUILDING ENVELOPE
<br />ROUND AND OVAL
<br />DUCT WRAP
<br />R-VALUE EQUAL TO BUILDING ENVELOPE,
<br />NOTE 1
<br />THICKNESS AS REQUIRED
<br />NOTES:
<br />1- INSULATE OUTSIDE, EXHAUST, AND RELIEF AIR DUCTS FROM BUILDING ENVELOPE TO BACKDRAFT DAMPER WITH R-VALUE EQUAL TO BUILDING ENVELOPE THICKNESS
<br />VICINITY MAP