f 1112 Permit Inspections <br /> VE R E T T city of Everett <br /> WASHINGTON <br /> 5/24/2023 5/24/2023 PLUMB 08-FINAL JEFF M RHODE CORRECTION see notes <br /> REQUIRED <br /> Notes: <br /> zendertodd@gmail.com <br /> -secure three compartment sink and faucet to wall-separate indirect drain required for separate food handling fixtures-water must be temper at hand <br /> wash sinks in kitchen-provide hammer arrestor for dishwasher in kitchen-provide hammer arrestor for dishwasher in bar area-floor clean outs to be <br /> installed-provide hammer arrestor for ice machine-provide hammer arrestor for water cooler-finish installation of dish washer in kitchen and bar area- <br /> trim condensate drains and turn down into mop sink-floor drain covers installed-support pex every 32 inches horizontal at water heater-provide <br /> vacuum breaker for water heater mounted above fixtures <br /> 5/26/2023 5/26/2023 PLUMB 08-FINAL JEFF M RHODE PARTIAL see notes <br /> APPROVAL <br /> Notes: <br /> zendertodd@gmail.com <br /> 360-820-1736 <br /> -in floor clean out covers required <br /> 6/7/2023 6/7/2023 PLUMB 08-FINAL JEFF M RHODE APPRVD-PERMIT see notes <br /> FINAL <br /> Notes: <br /> -inspection preformed when mechanical inspection was performed at tenant next door 1712. <br /> -floor clean out covers installed. <br /> i1 <br /> Printed:Thursday,08 June,2023 2 of 2 SUPERION <br />