Laserfiche WebLink
■ ■ SUNSYSTEM BONDING & GROUNDING ' BLUE RAVEN <br /> Ono FRAME <br /> 19 <br /> M <br /> M <br /> MICRORAILTM 03 N.Research INSTALLATION GUIDE ; PAGE 140rem,UT84097F M vay <br /> 800.377.4480 <br /> --———————————————————————————————————————————————————————————————————————————————————————————— ——————————————————————————————— WWW.BLUERAVENSOLAR.COM <br /> ® CONFIDENTIAL-THE INFORMATION <br /> HEREIN CONTAINED SHALL NOT BE <br /> USED FOR THE BENEFIT OF ANYONE <br /> EXCEPT BLUE RAVEN SOLAR NOR <br /> SHALL IT BE DISCLOSEDIN WHOLE OR <br /> IN PART TO OTHERS OUTSIDE <br /> o RECIPIENTS ORGANIZATION,EXCEPT <br /> IN CONNECTION WITH THE SALE AND <br /> USE OF THE RESPECTIVE EQUIPMENT, <br /> WITHOUT THE WRITTEN PERMISSION <br /> o OF BLUE RAVEN SOLAR LLC. <br /> f' <br /> NABCEP <br /> CERTIFIED <br /> PV INSTALLATION <br /> PROFESSIONAL <br /> Scott Gurney <br /> #PV-011719-015866 <br /> E-W BONDING PATH: CONTRACTOR: <br /> E-W module to module bonding is accomplished BRS FIELD OPS <br /> with 2 pre-installed bonding pins which engage 385-498-6700 <br /> on the secure side of the MicrorailTM and splice. <br /> I <br /> I <br /> Star Washer is WEEBLUG <br /> Single Use Only Single Use Only Alternate method <br /> N-S BONDING PATH: <br /> TERMNALTORQUE, N-S module to module bonding is <br /> Install Conductor and accomplished with bonding clamp with 2 integral <br /> torque to the following: TERMNALTORQUE, TERMNALTORQUE, bonding pins. (refer also to alternate method) <br /> 4-6 AWG 35in-lbs Install Conductor and Install Conductor and <br /> 8 AWG 25 in-lbs torque to the following: torque to the following: <br /> 10-14 AWG 20 in-lbs 4-14 AWG 35in-lbs 6-14 AWG 7ft-lbs 11 <br /> ' DRAWING BY: <br /> LUG DETAIL& TORQUE INFO LUG DETAIL& TORQUE INFO LUG DETAIL& TORQUE INFO <br /> Ilsco Lay-In Lug (UBLr4DBT) Ilsco Flange Lug (SGB-4) Wiley WEEBLug (6.7) PLOT DATE: <br /> • 10-32 mounting hardware 0 1/4" mounting hardware 0 1/4" mounting hardware <br /> • Torque = 5 ft-lb 0 Torque = 75 in-lb 0 Torque = 10 ft-lb Alternate method <br /> �'- PROJECT NUMBER: <br /> • AWG 4-14-Solid or Stranded 9 AWG 4-14-Solid or Stranded AWG 6-14-Solid or Stranded <br /> TRIMRAIL BONDING PATH: <br /> NOTE: ISOLATE COPPER FROM ALUMINUM CONTACTTOPREVENT CORROSION Trimrail to module bonding is accomplished with SHEET NAME: <br /> System bonding is accomplished through modules. System grounding accomplished by attaching bonding clamp with integral bonding pin and <br /> SPEC SHEET <br /> a ground lug to any module at a location on the module specified by the module manufacturer. bonding T-bolt. (refer also to alternate method) REVISION: PAGE NUMBER: <br /> ---- SS <br />