My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1111 80TH ST SW JAMCO 2024-05-03
>
Address Records
>
80TH ST SW
>
1111
>
JAMCO
>
1111 80TH ST SW JAMCO 2024-05-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/3/2024 3:53:44 PM
Creation date
9/13/2023 10:57:18 AM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1111
Tenant Name
JAMCO
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D9127 Series POPIT Modules <br /> Region Certification POPIT to Sensor Loops <br /> The number of detection devices each sensor loop can <br /> FDNY- 6059 supervise is limited only by the resistance on the loop. <br /> CoA Resistance on each sensor loop must be less than <br /> CSFM 7167-1615:0100 CONTROL UNIT 100 Q not including the end-of-line (EOL) resistor. <br /> (HOUSEHOLD) Certain UL and National Fire Protection Association <br /> CSFM 7165-1615:0113 FIRE ALARM CON- (NFPA) applications can limit the number of detection <br /> TROL UNIT(COMMERCIAL) devices. Consult the appropriate UL or NFPA <br /> standards. <br /> CSFM 7167-1615:0243 Terminate each POPIT sensor loop with the 33 kO EOL <br /> CSFM 7165-1615:0119 resistor included with each POPIT. <br /> Use a twisted-pair wire (six twists per foot) in all <br /> Instal lation/configu ration notes POPIT installations for both the data expansion loop <br /> wiring and the POPIT sensor loops. Run wires away <br /> Compatibility Information from AC sources to prevent AC induction. <br /> Control Panels All G Series control panels,D9412,D7412, Parts included <br /> D7212,D7212131,D9112,D9112131, <br /> D8112G1,D8112G2,and D9124 <br /> Quantit Component <br /> Module D8125 y <br /> The D8125 Multiplex Zone Expander is required. The 1 PORT module <br /> D9127 modules are wired in parallel on the D8125 <br /> 1 33 k0 EOL resistor <br /> data loop. <br /> Number of POPIT Modules per Control Panel <br /> 1 Magnet(D9127T only) <br /> D7212G,D7212GV2,D7212GV3 32 D9127 POPITs 1 Hardware pack <br /> D7212131 40 D9127 POPITs 1 Literature pack <br /> D7212,D7412,D7412G,D7412GV2, 67 D9127 POPITs Technical specifications <br /> D7412GV3 <br /> Environmental Considerations <br /> D9124 119 D9127 POPITs <br /> Relative Humidity: Up to 93%non-condensing <br /> D9112131 126 D9127 POPITs <br /> D9112,D9412,D9412G,D9412GV2, 238 D9127 POPITs Temperature(operating): 0°C to+50°C(+32'F to+122°F) <br /> D9412GV3 Properties <br /> Wiring Considerations Color: Off white <br /> Wire Size Maximum Length of all Data Dimensions: 8.1 cm x 3.8 cm x 2.4 cm <br /> Expansion Loops Combined (3.2 in.x 1.5 in.x 0.9 in.) <br /> 0.8 mm(22 AWG) 549 m(1800 ft) Material: UL Listed fire-resistant <br /> 1.0 mm(20 AWG) 881 m(2890 ft) Power Requirements <br /> 1.2 mm(18 AWG) 1402 m(4600 ft) <br /> Current Draw 0.8 mA maximum <br /> 1.5 mm(16 AWG) 2231 m(7320 ft) <br /> Resistance: Maximum increase in resistance on the POPIT <br /> 1.8 mm(14 AWG) 3551 m(11650 ft) loop is 1000 0.Maximum resistance between <br /> the D8125 module and each POPIT is 90 0. <br /> D8125 to POPIT Loops <br /> Use one two-wire data expansion loop, or distribute Voltage(operating): 12VDCnominal <br /> the POPITs on up to three loops. The maximum <br /> lengths shown in the following table are for all data Sensor Loop <br /> expansion loops combined connected to the same Resistance: Maximum resistance on the sensor loop is 1000. <br /> D8125 module. Setting DIP switches on the POPIT <br /> modules assigns them to point numbers. The switch Response Time: 1 sec approximately <br /> setting on each POPIT assigns it a point number, <br /> regardless of its physical location. <br />
The URL can be used to link to this page
Your browser does not support the video tag.