My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1111 80TH ST SW JAMCO 2024-05-03
>
Address Records
>
80TH ST SW
>
1111
>
JAMCO
>
1111 80TH ST SW JAMCO 2024-05-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/3/2024 3:53:44 PM
Creation date
9/13/2023 10:57:18 AM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1111
Tenant Name
JAMCO
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N <br /> A/C SUPPLY OR N <br /> RETURN DIFFUSER NOTE: MEASUREMENTS <br /> SHOWN ARE To THE <br /> 4° MIN CLOSEST POINT OF Q <br /> Mathew Buntin CEILING <br /> NICET#144348 4"MIN DETECTOR W c o <br /> CEILING-MOUNTED � 36"MIN.� M <br /> HEAT DETECTOR / 6"MIN. AUDIBLE ONLY 12" MAX <br /> 12" MAX AUDIBLE VISUAL CEILING MOUNTED W Z <br /> Fire Alarm / APPLIANCES SMOKE/HEAT W C) Lj <br /> CERTIFIED NEVER AND/OR vlsuAL <br /> Systems Level III HERE _ONLY APPLIANCE DETECTOR Q Q L R <br /> WALL-MOUNTED HORN/STROBES AND/OR TOP OF HORN SHALL BE WALL-MOUNTED '6 � 4' 1.- <br /> HEAT DETECTOR STROBES SHALL BE MOUNTED 6"BELOW THE SMOKE DETECTOR M }b <br /> MOUNTED SUCH THAT THE CEILING OR 90"ABOVE V M r <br /> ® ENTIRE LENS IS NOT FINISHED FLOOR, N Q O O <br /> Security Solutions LESS THAN 80"AND NOT WHICHEVER IS LOWER. v J 00 v < <br /> GREATER THAN 96" <br /> o" 96" ABOVE FINISHED FLOOR. SIDE WALL <br /> 66'" MANUALr <br /> PULL �5' MAX. W <br /> STATION FINISHED J <br /> CERT NO.144341 VALID Ti RU 03/01/2023 ®- WALL L <br /> 1Z <br /> U <br /> FINISHED %A <br /> FLOOR <br /> FIRE ALARM DEVICE MOUNTING HEIGHTS <br /> SLALE:NOT TO SCALE <br /> NOTES: <br /> c <br /> 1. LOCATE CEILING MOUNTED HEAT/SMOKE DETECTORS ON THE BOTTOM OF THE DECK/SUSPENDED CEILING 2 <br /> (NOT ON BOTTOM OF STRUCTURAL MEMBERS),AND AS INDICATED IN NEPA 72. c <br /> 2. LOCATE CEILING MOUNTED NOTIFICATION DEVICES ON BOTTOM OF BEAMS OR JOISTS;WITH CLEAR LINE a <br /> OF SITE IN ALL DIRECTIONS; NO GREATER THAN THIRTY(30)FEET ABOVE THE FINISHED FLOOR;AND AS <br /> INDICATED IN NEPA 72. <br /> 3.LOCATE CEILING MOUNTED NOTIFICATION DEVICES FLUSH WITH THE SUSPENDED CEILING;ALIGNED WITH <br /> LIGHTING,SPRINKLERS,AND OTHER ARCHITECTURAL FIXTURES;WITH CLEAR LINE OF SITE IN ALL <br /> DIRECTIONS;NO GREATER THAN THIRTY(30)FEET A.F.F. ;AND AS INDICATED IN NEPA 72. <br /> SBUS T T T 4.LOCATE WALL MOUNTED NOTIFICATION DEVICES AT 80"A.F.F TO BOTTOM OF BACK BOX. p <br /> 8 4 AWG 5. COORDINATE EXACT MOUNTING HEIGHT OF CONTROL PANELS,ANNUNCIATORS,AND POWER SUPPLIES <br /> / WITH THE GENERAL CONTRACTOR,ELECTRICAL CONTRACTOR AND AHJ PRIOR TO INSTALLATION. a <br /> G. MEASURED TO THE OPERABLE PART OF THE PULL STATION. <br /> I�'C 1�IC c <br /> WF TO EXISTING SIGNALING APPLIANCES <br /> LACP vv VVI <br /> SBUS EXISTING <br /> #18/4 AWG OUT <br /> SLG o 0 <br /> SBUS IN <br /> N N <br /> II C'j <br /> ADDRESSABLE #18/2 AWG CLASS B) N <br /> ( <br /> #18/4 AWG FIRE ALARM CONTROL COMMUNICATOR l <br /> °oE ` K E tai <br /> ©:_ <br /> d W v c <br /> o TO EXISTING NOTIFICATION APPLIANCES <br /> SBUS FROM ��� so z° a z° <br /> --o <br /> EXIST. FACP <br /> OR EOL c i z o 2 <br /> NAC-1 TO EXISTING NOTIFICATION APPLIANCES D ° <br /> R E o - d <br /> O o v � ii D a > <br /> NAC-2 TO EXISTING NOTIFICATION APPLIANCES <br /> #18/2AWG <br /> NAC-3 TO EXISTING NOTIFICATION APPLIANCES <br /> 04#14/2 AWG (CLASS B) O CD <br /> O CD <br /> 120VAC ti Q <br /> (DEDICATED CKT.) NAC-4 M <br /> O O <br /> #14/2 AWG (CLASS B) O0 Cl) C o <br /> � <br /> CV) <br /> Q c <br /> BATTERY BATTERY r <br /> po <br /> U CO a @ <br /> r <br /> r W a <br /> ui <br /> E <br /> Z <br /> U <br /> d <br /> O <br /> a` <br /> FIRE ALARM RISER DIAGRAM Sheet Number <br /> SCHEMATIC: NO SCALE RISER <br /> 2of3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.