Laserfiche WebLink
N <br /> A/C SUPPLY OR N <br /> RETURN DIFFUSER NOTE: MEASUREMENTS <br /> SHOWN ARE To THE <br /> 4° MIN CLOSEST POINT OF Q <br /> Mathew Buntin CEILING <br /> NICET#144348 4"MIN DETECTOR W c o <br /> CEILING-MOUNTED � 36"MIN.� M <br /> HEAT DETECTOR / 6"MIN. AUDIBLE ONLY 12" MAX <br /> 12" MAX AUDIBLE VISUAL CEILING MOUNTED W Z <br /> Fire Alarm / APPLIANCES SMOKE/HEAT W C) Lj <br /> CERTIFIED NEVER AND/OR vlsuAL <br /> Systems Level III HERE _ONLY APPLIANCE DETECTOR Q Q L R <br /> WALL-MOUNTED HORN/STROBES AND/OR TOP OF HORN SHALL BE WALL-MOUNTED '6 � 4' 1.- <br /> HEAT DETECTOR STROBES SHALL BE MOUNTED 6"BELOW THE SMOKE DETECTOR M }b <br /> MOUNTED SUCH THAT THE CEILING OR 90"ABOVE V M r <br /> ® ENTIRE LENS IS NOT FINISHED FLOOR, N Q O O <br /> Security Solutions LESS THAN 80"AND NOT WHICHEVER IS LOWER. v J 00 v < <br /> GREATER THAN 96" <br /> o" 96" ABOVE FINISHED FLOOR. SIDE WALL <br /> 66'" MANUALr <br /> PULL �5' MAX. W <br /> STATION FINISHED J <br /> CERT NO.144341 VALID Ti RU 03/01/2023 ®- WALL L <br /> 1Z <br /> U <br /> FINISHED %A <br /> FLOOR <br /> FIRE ALARM DEVICE MOUNTING HEIGHTS <br /> SLALE:NOT TO SCALE <br /> NOTES: <br /> c <br /> 1. LOCATE CEILING MOUNTED HEAT/SMOKE DETECTORS ON THE BOTTOM OF THE DECK/SUSPENDED CEILING 2 <br /> (NOT ON BOTTOM OF STRUCTURAL MEMBERS),AND AS INDICATED IN NEPA 72. c <br /> 2. LOCATE CEILING MOUNTED NOTIFICATION DEVICES ON BOTTOM OF BEAMS OR JOISTS;WITH CLEAR LINE a <br /> OF SITE IN ALL DIRECTIONS; NO GREATER THAN THIRTY(30)FEET ABOVE THE FINISHED FLOOR;AND AS <br /> INDICATED IN NEPA 72. <br /> 3.LOCATE CEILING MOUNTED NOTIFICATION DEVICES FLUSH WITH THE SUSPENDED CEILING;ALIGNED WITH <br /> LIGHTING,SPRINKLERS,AND OTHER ARCHITECTURAL FIXTURES;WITH CLEAR LINE OF SITE IN ALL <br /> DIRECTIONS;NO GREATER THAN THIRTY(30)FEET A.F.F. ;AND AS INDICATED IN NEPA 72. <br /> SBUS T T T 4.LOCATE WALL MOUNTED NOTIFICATION DEVICES AT 80"A.F.F TO BOTTOM OF BACK BOX. p <br /> 8 4 AWG 5. COORDINATE EXACT MOUNTING HEIGHT OF CONTROL PANELS,ANNUNCIATORS,AND POWER SUPPLIES <br /> / WITH THE GENERAL CONTRACTOR,ELECTRICAL CONTRACTOR AND AHJ PRIOR TO INSTALLATION. a <br /> G. MEASURED TO THE OPERABLE PART OF THE PULL STATION. <br /> I�'C 1�IC c <br /> WF TO EXISTING SIGNALING APPLIANCES <br /> LACP vv VVI <br /> SBUS EXISTING <br /> #18/4 AWG OUT <br /> SLG o 0 <br /> SBUS IN <br /> N N <br /> II C'j <br /> ADDRESSABLE #18/2 AWG CLASS B) N <br /> ( <br /> #18/4 AWG FIRE ALARM CONTROL COMMUNICATOR l <br /> °oE ` K E tai <br /> ©:_ <br /> d W v c <br /> o TO EXISTING NOTIFICATION APPLIANCES <br /> SBUS FROM ��� so z° a z° <br /> --o <br /> EXIST. FACP <br /> OR EOL c i z o 2 <br /> NAC-1 TO EXISTING NOTIFICATION APPLIANCES D ° <br /> R E o - d <br /> O o v � ii D a > <br /> NAC-2 TO EXISTING NOTIFICATION APPLIANCES <br /> #18/2AWG <br /> NAC-3 TO EXISTING NOTIFICATION APPLIANCES <br /> 04#14/2 AWG (CLASS B) O CD <br /> O CD <br /> 120VAC ti Q <br /> (DEDICATED CKT.) NAC-4 M <br /> O O <br /> #14/2 AWG (CLASS B) O0 Cl) C o <br /> � <br /> CV) <br /> Q c <br /> BATTERY BATTERY r <br /> po <br /> U CO a @ <br /> r <br /> r W a <br /> ui <br /> E <br /> Z <br /> U <br /> d <br /> O <br /> a` <br /> FIRE ALARM RISER DIAGRAM Sheet Number <br /> SCHEMATIC: NO SCALE RISER <br /> 2of3 <br />