My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10521 19TH AVE SE ALLIED TELESIS INC 2025-03-27
>
Address Records
>
19TH AVE SE
>
10521
>
ALLIED TELESIS INC
>
10521 19TH AVE SE ALLIED TELESIS INC 2025-03-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2025 2:43:30 PM
Creation date
9/13/2023 11:43:17 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10521
Tenant Name
ALLIED TELESIS INC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> jeffrey@precise-hvac.com <br /> From: Drew Martin <dmartin@everettwa.gov> <br /> Sent: Monday, February 27, 2023 1:49 PM <br /> To: permits@precise-hvac.com <br /> Subject: City of Everett Permit Services: 10521 19th Avenue SE (M2302-007) - First Building <br /> Review <br /> Hello,Jeffrey. <br /> We have completed the first review of the building plans for this project. This email will serve as the review letter. The <br /> comments below should be addressed. Two revised full-sized hard-copies of the drawings should be submitted for <br /> review. An itemized response letter stating how each comment has been addressed should be included with the <br /> drawing. Additional revised documentation, including but not limited structural calculations and other supporting <br /> documentation, should be submitted as required. <br /> Comments <br /> 1. The proposed work includes suspended equipment exceeding 20 lbs. This equipment requires <br /> independent support and seismic bracing. Details should be included in the drawings. Calculations <br /> substantiating the design should be submitted for review. The design should comply with ASCE 7-16 <br /> Chapter 13. See IBC Section 1613.1. <br /> 2. The proposed work includes one or four rooftop units each weighing 1,627 lbs. The following comments should <br /> be addressed: <br /> a. Calculations evaluating the strength of the roof structure supporting the units in addition to existing <br /> loads (e.g., self-weight, snow, etc.), including but not limited to joists and supporting beams and <br /> columns, should be submitted for review. See IBC Section 1604.1 and 1604.4. <br /> b. Details for the installation of the units should be submitted for review. <br /> c. Continuing with the previous comment, an additional Building permit application must be submitted if <br /> structural modifications are required. Minor modifications such as penetrations through and blocking of <br /> the roof sheathing to create small duct openings may be included in the Mechanical permit <br /> details. Note that if a Building permit application is required,the Mechanical permit cannot be issued <br /> until the Building permit is approved. <br /> Please contact me if you have questions. Thank you. <br /> Drew Martin, P.E.,S.E. <br /> iiii <br /> - Associate Engineer—Commercial Plans Examiner I Permit Services <br /> 425.257.8810 13200 Cedar Street, 2nd Floor, Everett,WA 98201 <br /> EVERETT Phone Hours: M/W/T: 8 am - 12 pm & 1 pm—3 pm;Tu: 1:O0pm-3:O0pm <br /> everettwa.gov/permits I Facebook I Twitter <br /> Note:Emails and attachments sent to and from the City of Everett are public records and may be subject to disclosure pursuant to the Public <br /> Records Act. <br />
The URL can be used to link to this page
Your browser does not support the video tag.