Laserfiche WebLink
CONTRACTOR INFORMATION <br /> SUNERGUYSTEMS <br /> Employee Owned <br /> (N) SUNMODO EZ ROOF MOUNT KIT <br /> WITH L-MOUNT <br /> (E) COMPOSITION SHINGLE ROOF SUNERGY SYSTEMS INC. <br /> (N) SUNMODO SMR100 RAIL MEMBRANE ADDRESS: 4546 LEARY WAY <br /> (E) 2"X 4" TOP CHORD @ 24" O.C. NORTHWEST, SEATTLE, 98107 <br /> (N) SOLAR MODULE SPACING <br /> PHONE NUMBER: (206) 302-9464 <br /> LICENSE NUMBER: SUNERS1905D4 <br /> CUSTOMER INFORMATION <br /> NAME: KELLY MANEMAN <br /> 6" MAX ADDRESS: 5102 SEAHURST AVENUE, <br /> EVERETT, WA 98203 <br /> COORDINATES: 47.950630, <br /> -122.243756 <br /> APN: 00581100100000 <br /> 16.810kW DC / 14.309kW AC ROOF <br /> (E) ROOF DECKING MOUNT PV SYSTEM <br /> - - - - - - - - - - - - - - - - - - - <br /> - - - - - - - - - <br /> DEAD <br /> - - - - - - - -DEAD LOAD CALCULATIONS <br /> TOTAL <br /> BOM QUANTITY LBS/UNIT WEIGHT (LBS) <br /> MODULES 41 45 1845 <br /> MID-CLAMP 64 0.14 8.96 <br /> END-CLAMP 36 0.24 8.64 <br /> RAIL LENGTH 313 0.41 128.33 <br /> SPLICE BAR 12 0.56 6.72 - - - - - - - - - - - - - - - - _ _ _ _ _ _ _ _ _ _ _ J PROJECT ID AUR-83774 <br /> SUNMODO EZ ROOF SCALE: NTS DATE 8/18/2023 <br /> MOUNT KIT WITH 94 1.12 105.28 (N) SUNMODO EZ ROOF MOUNT KIT <br /> L-FOOT WITH L-MOUNT CREATED BY SSB <br /> (N) STAINLESS STEEL 5/16" LAG BOLT <br /> MICROINVERTER 41 2.38 97.58 MIN. 2.5" EMBEDMENT PILOT HOLE <br /> TOTAL WEIGHT OF THE SYSTEM (LBS) 2200.51 <br /> REQUIRED SIGNATURE <br /> TOTAL ARRAY AREA ON THE ROOF (SQ. FT.) 816.58 (E) 2" X 4" TOP CHORD @ 24" O.C. STRUCTURAL DETAILS <br /> WEIGHT PER SQ. FT.(LBS) 2.69 SPACING PV-3.1 <br /> WEIGHT PER PENETRATION (LBS) 23.4 <br />