(E) POTTER AFC-1 000
<br /> The Symbol of Protection Fire Alarm Control Panel
<br /> Features - -- •PySEMB�Fo
<br /> • 1,270 addresses available on this analog addressable system
<br /> • Additional system capacity achieved via multi-point SLC modules
<br /> • 1500 software zones Orar_rEx AFC-1000
<br /> • NFPA 72 Compliant Smoke Sensitivity Test Built-In
<br /> • System Operates as Class A or Class B for SLC,P-Link and NACs
<br /> • 10 Amp Power Supply,Expandable to 315 amps
<br /> • 6 NACS,Regulated,Rated at 3 Amps each,expandable to 192
<br /> • 4 Input/Output(1/0)Circuits for system flexibility rated at 1 Amp each
<br /> • Strobe Synchronization and System Wide Sync for Gentex®,
<br /> AMSECO®,Cooper Wheelock®and System Sensor®strobes
<br /> • Dedicated Alarm,Supervisory and Trouble Relays
<br /> • 4,000 Event History Buffer
<br /> • Optional two line DACT with UD-2000 that can report General,Zone or
<br /> Point Information
<br /> • Built in IP communicator
<br /> • Ethernet Port for Programming and Network Connectivity
<br /> • E-Mail System Status,Reports and Event Information
<br /> • Product includes 5 year warranty O
<br /> ONYC Fire Dept.Certificate of Approval
<br /> APPROVED 6256 LISTED
<br /> 7165-0328:0509 S735
<br /> Description Technical Specifications
<br /> The AFC-1000 is an expandable analog/addressable releasing fire alarm Dimensions 18%6"W x 27/,"H x 4/e"D
<br /> system with a total system capacity of 1270 addresses.Additional capacity 5.0 Amps @ 120 VAC 50/60 HZ
<br /> on the system is achieved using multi-point SLC modules The control AC Mains 3.0 Amps @ 240 VAC 50/60 HZ
<br /> panel utilizes the exclusive Potter protocol that includes a complete line of
<br /> sensors and modules.Each SLC may be comprised of any combination of Enclosure 16 gauge cold rolled steel with removable smoke sensor,heat detectors or modules and allows for a total of 50 ohms locked door with Lexan viewing window
<br /> of impedance and may use any wire compliant with the National Electrical Standby Current-130 mA
<br /> Code(NEC). Alarm Current-220 mA
<br /> The AFC-1000 has a 10 Amp power supply with six Notification 10 Amps power for NACS,I/O,and P-Link
<br /> Appliance Circuits (NACS) and four Input/Output (UO) circuits. The Battciy 3 Amps per NAC,regulated
<br /> NACS are rated at 3 Amps each and the I/Os are rated at 1 Amp each. 1 Amp per UO circuit,regulated
<br /> Each output is regulated and power limited. In addition, each output is Battery Charger range 8-55 Ah
<br /> uniquely programmable and may be configured for steady signal,strobe Battery Charger voltage 27.3 VDC
<br /> synchronization, constant power, door holder power, or releasing. The P-Link maximum current of 1 Amp
<br /> strobe synchronization includes Gentex,AMSECO, System Sensor and Temperature and 321 to 1201(0°C to 49°C)with a maximum
<br /> Cooper/Wheelock and with the exclusive Quadrasync each output may Humidity Range humidity of 93%non-condensing.
<br /> have a unique brand and all strobes will flash together. NFPA, 13,15, 16, 17, 17A,70,72,and 750
<br /> The NACS may be expanded using the PSN-1000 series intelligent power ANSI/UL 864-Local(L),Remote Station
<br /> supplies. Each PSN-1000 adds another 10 Amps of power,2 additional (RS),Central Station(CS),Propriety
<br /> input circuits and the AFC-1000 will support up to 31 power supplies.The (PPU),Auxiliary(AUX).Type of Service:
<br /> system will synchronize the strobes system wide. In addition,the PSN- Automatic(A),Manual(M),Water flow
<br /> 1000E has space to allow the installation of up to six PAD 100-SLCE SLC Standards (WF)Sprinkler Supervisory(SS)Type of
<br /> loop expansion cards.The cards mount on a stacker bracket that allows Signaling:Digital Alarm Communicator
<br /> access to all SLC circuit connections. (DAC),March Time(March),Non Coded
<br /> (NC),Reverse Polarity(Rev Pol),Other
<br /> Technologies(OT)
<br /> • IBC(International Building Code)
<br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com
<br /> 8830135-REV K 5/23 PAGE 1 OF 5