Laserfiche WebLink
(E) POTTER AFC-1 000 <br /> The Symbol of Protection Fire Alarm Control Panel <br /> SLC Features RA-6075R—2 x 16 LCD annunciator with a key pad in a locked <br /> The Potter protocol is a digital protocol with a proven design for metal enclosure. <br /> reliability and noise immunity.The system does not require special RA-6500R(F)—4 x 40 LCD annunciator with a key pad in a locked <br /> cable or conductors for connection of the Signaling Line Circuit metal enclosure.Flush mount version available. <br /> as long as the cable is compliant with NFPA 70 and NFPA 72. LED-16(F)—16 LED annunciator with common indicators in a <br /> The system allows for Class A or Class B installations as well as locked metal enclosure.Flush mount version available. <br /> "T-Taps."Each loop is capable of 127 points,with a max wiring PSN-1000(E)—10 amp,remote intelligent power supply with <br /> distance of 10,000 ft. 6 NACs,2 Inputs and a P-Link repeater.This panel is listed in <br /> conjunction with the AFC-100 as releasing circuits <br /> Sensor Features CA-6500—Class A convertor that converts the SLC,NACs and <br /> The sensors through the fire alarm control panel provide a real P-Link connection <br /> time status as to the condition of the system.The smoke detector UD-2000—UL listed,Dual line telephone alarm communicator <br /> sensitivity,heat detector temperature level and drift compensation DRV-50—LED driver expander,used to connect up to 50 LEDs in a <br /> are all programmable options.The system also allows for a day/night graphic display <br /> mode where the panel automatically adjusts the sensitivity depending FCB-1000—Fire communication bridge,provides remote mounting <br /> on the time of day.To assist in the reduction of false alarms,the of the Ethernet connection <br /> smoke detectors also have a maintenance warning that sends a trouble <br /> signal when a detector is dirty to the point that it can no longer FIB-1000—Fiber interface module,used to extend P-Link to multi- <br /> maintain the programmed sensitivity. mode fiber(2 required) <br /> RLY 5—Relay module,provides 5 form C relay contacts rated at 3.0 <br /> User Interface amps24VDC/125AC <br /> The fire alarm control panel has a 4 x 40 LCD display to provide SPG-1000—Serial parallel gateway,allows for the connection to a <br /> information to the system status.The keypad has navigation keys serial or parallel printer <br /> to allow manipulation of the Menu on board the panel.The panel is The FIB-1000,FCB-1000 and the SPG-1000 may be installed in the <br /> shipped standard with the following LEDs: stacker bracket or ordered with the optional rack mount enclosure. <br /> • AC Power-Green MC-1000 Multi-Connect allows up to sixty-three AFC series panels <br /> • Alarm-Red to share a single reporting technology. <br /> • Earth Fault-Amber IDC-6—Initiating device circuit provides 6 programmable inputs <br /> • Supervisory-Amber AE-2—Two card expansion cabinet <br /> • Silenced-Amber AE-8—Eight card expansion cabinet <br /> • Trouble-Amber AE-14—Fourteen card expansion cabinet <br /> • Pre-Release-Amber <br /> • Release-Red Ethernet/I.P. Connection <br /> The AFC-1000 is shipped standard with an Ethernet connection. <br /> The common buttons include a Silence,Reset,Acknowledge,and This connection is the programming port and may be connected <br /> Drill.All of the buttons are accessible once the locked door is to a building Wide Area Network(WAN)or Local Area Network <br /> opened. (LAN).Once connected to the Internet,the panel may be selectively <br /> programmed to e-mail alarm conditions,trouble conditions, <br /> P-Link supervisory conditions,test,Event History and detector status.An <br /> The AFC-1000 has a proprietary communication protocol that e-mail may be sent to the panel and the panel will e-mail the event <br /> communicates through a RS-485 connection to field devices.Up history,detector status,configuration file or server status to an <br /> to 64 devices may be connected to a single P-Link connection.The authorized E-mail account.In addition,reminders may be set to send <br /> P-Link includes the communication terminals and regulated 24 VDC an e-mail for service,testing or other conditions. <br /> connection for the field devices.The field devices may be any of the <br /> following: In addition,the Ethernet connection is UL listed as an IP <br /> communicator.The IP communicator is listed to report to the UL <br /> PAD100-SLOE-Analog/Addressable loop expansion module listed Sur-Gard III IP receiver.The IP communicator replaces the <br /> SLCE-127-Nohmi addressable loop expansion module for retrofit traditional less reliable alarm communicator transmitter that utilized <br /> applications. telephone lines.The IP communicator is an active method of <br /> connection and communication to the monitoring station. <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 8830136-REV K 5/23 PAGE 4 OF 5 <br />