(E) POTTER PAD 100-ZM <br /> The Symbol of Protection Conventional Zone Module <br /> Features Q�S�MB�Fo <br /> • Compatible with conventional 2-wire smoke detectors « <br /> • IDC can be wired One(1)Class A or Two(2)Class B A i . Q <br /> • Monitors presence of 24VDC Aux Power 2 THE V� <br /> • SLC Class A,Class X&Class B J <br /> • Mounts in a standard 4"or double gang box <br /> • Wiring terminals accessible when mounted in box jw"'w <br /> • All wiring terminals accept 22 to 12AWG <br /> • Product includes a 5 year warranty <br /> • UUKL Listed for Smoke Control <br /> APPROVED <br /> Description Technical Specifications <br /> The PAD 100-ZM module uses one(1)address on an SLC Loop when Operating Voltage 24.OV <br /> monitoring two (2) Class B or one (1) Class A circuit. The module <br /> requires and supervises a 24VDC auxiliary power connection. The Max SLC Standby Current 240µA <br /> 24VDC power source must be either a Potter IPA series addressable <br /> panel, or a Potter PSN series power supply. The IDC may be wired Max SLC Alarm Current 240µA <br /> Class B or Class A which is selectable by an on board DIP switch.The Aux Power Required 19-28V <br /> PAD 100-ZM employs one red LED to indicate the module's status.In Max Detector Standby <br /> normal condition,the LED flashes when the device is being polled by Current of IDC at 24 VDC ImA <br /> the control panel.When a device is activated,the LED will flash at a Max Module Alarm Current <br /> fast rate. 50mA <br /> of IDC at 24 VDC <br /> Application Max Wiring Resistance of <br /> The PAD100-ZM is compatible with Potter's IPA and AFGARC <br /> IDC <br /> Ioosz <br /> series addressable fire alarm control panels. The PAD100-ZM is Max Wiring Capacitance 1µF <br /> used to supervise a zone of conventional 2-wire smoke detectors on of IDC <br /> an Initiating Device Circuit (IDC). The PAD100-ZM is capable of EOL Resistor 5.IK92 <br /> monitoring two(2)separate Class B or one(1)Class A circuits. <br /> Operating Temperature 32 to 120°F(0 to 49°C) <br /> Setting the Address Range <br /> Each addressable SLC device must be assigned an address. The Operating Humidity Range 0 to 93%(non-condensing) <br /> address is set using the DIP switch located on the PAD 100-ZM.When Max no.of Module Per <br /> the PAD100-ZM is used to monitor two individual Class B circuits Loo 127 units <br /> a single device address is assigned, each input is then identified as a p <br /> sub-point of the module address.For example,if the address number Dimensions 4.17"(106mm)L x 4.17" <br /> is assigned as"8",the B1 input will be"8.1"and the B2 input will be (I06mm)W x 1.14"(29mm)D <br /> "8.2"• Standard 4"Square or <br /> Mounting Options <br /> Before connecting a device to the SLC loop, take the following Double Gang Box <br /> precautions to prevent potential damage to the panel or device: Shipping Weight 0.6 lbs <br /> 1. Power to the device is removed. <br /> 2. Field wiring is correctly installed. <br /> 3. Field wiring has no open or short circuits. <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 8830085-REVD 12/18 PAGE 1 OF 4 <br />