My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7505 HARDESON RD BETHEL CHURCH 2023-10-25
>
Address Records
>
HARDESON RD
>
7505
>
BETHEL CHURCH
>
7505 HARDESON RD BETHEL CHURCH 2023-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 9:07:12 AM
Creation date
9/18/2023 7:23:48 AM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7505
Tenant Name
BETHEL CHURCH
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(E) POTTER PAD 100-ZM <br /> The Symbol of Protection Conventional Zone Module <br /> Features Q�S�MB�Fo <br /> • Compatible with conventional 2-wire smoke detectors « <br /> • IDC can be wired One(1)Class A or Two(2)Class B A i . Q <br /> • Monitors presence of 24VDC Aux Power 2 THE V� <br /> • SLC Class A,Class X&Class B J <br /> • Mounts in a standard 4"or double gang box <br /> • Wiring terminals accessible when mounted in box jw"'w <br /> • All wiring terminals accept 22 to 12AWG <br /> • Product includes a 5 year warranty <br /> • UUKL Listed for Smoke Control <br /> APPROVED <br /> Description Technical Specifications <br /> The PAD 100-ZM module uses one(1)address on an SLC Loop when Operating Voltage 24.OV <br /> monitoring two (2) Class B or one (1) Class A circuit. The module <br /> requires and supervises a 24VDC auxiliary power connection. The Max SLC Standby Current 240µA <br /> 24VDC power source must be either a Potter IPA series addressable <br /> panel, or a Potter PSN series power supply. The IDC may be wired Max SLC Alarm Current 240µA <br /> Class B or Class A which is selectable by an on board DIP switch.The Aux Power Required 19-28V <br /> PAD 100-ZM employs one red LED to indicate the module's status.In Max Detector Standby <br /> normal condition,the LED flashes when the device is being polled by Current of IDC at 24 VDC ImA <br /> the control panel.When a device is activated,the LED will flash at a Max Module Alarm Current <br /> fast rate. 50mA <br /> of IDC at 24 VDC <br /> Application Max Wiring Resistance of <br /> The PAD100-ZM is compatible with Potter's IPA and AFGARC <br /> IDC <br /> Ioosz <br /> series addressable fire alarm control panels. The PAD100-ZM is Max Wiring Capacitance 1µF <br /> used to supervise a zone of conventional 2-wire smoke detectors on of IDC <br /> an Initiating Device Circuit (IDC). The PAD100-ZM is capable of EOL Resistor 5.IK92 <br /> monitoring two(2)separate Class B or one(1)Class A circuits. <br /> Operating Temperature 32 to 120°F(0 to 49°C) <br /> Setting the Address Range <br /> Each addressable SLC device must be assigned an address. The Operating Humidity Range 0 to 93%(non-condensing) <br /> address is set using the DIP switch located on the PAD 100-ZM.When Max no.of Module Per <br /> the PAD100-ZM is used to monitor two individual Class B circuits Loo 127 units <br /> a single device address is assigned, each input is then identified as a p <br /> sub-point of the module address.For example,if the address number Dimensions 4.17"(106mm)L x 4.17" <br /> is assigned as"8",the B1 input will be"8.1"and the B2 input will be (I06mm)W x 1.14"(29mm)D <br /> "8.2"• Standard 4"Square or <br /> Mounting Options <br /> Before connecting a device to the SLC loop, take the following Double Gang Box <br /> precautions to prevent potential damage to the panel or device: Shipping Weight 0.6 lbs <br /> 1. Power to the device is removed. <br /> 2. Field wiring is correctly installed. <br /> 3. Field wiring has no open or short circuits. <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 8830085-REVD 12/18 PAGE 1 OF 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.