My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2925 WETMORE AVE CAFE UU 2023-10-25
>
Address Records
>
WETMORE AVE
>
2925
>
CAFE UU
>
2925 WETMORE AVE CAFE UU 2023-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 2:42:59 PM
Creation date
9/18/2023 7:43:20 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2925
Tenant Name
CAFE UU
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Drew Martin <br />From: Drew Martin <br />Sent: Wednesday, March 8, 2023 9:07 AM <br />To: cj@westernneon.com <br />Subject: City of Everett Permit Services: 2925 Wetmore Avenue (S2303-001) - First Building <br />Review <br />Hello, C.I. <br />We have completed the first review of the building plans for this project. This email will serve as the review letter. The <br />comments below should be addressed. Two revised full-sized hard -copies of the drawings should be submitted for <br />review. An itemized response letter stating how each comment has been addressed should be included with the <br />drawing. Additional revised documentation, including but not limited structural calculations and other supporting <br />documentation, should be submitted as required. <br />Comments <br />1. The proposed project involves installing a metal sign weighing 100 LBS or move above a pedestrian <br />walkway. The sign is proposed to be anchored to an existing unreinforced masonry (URM) surface and oriented <br />for exposure to wind loading. Calculations substantiating the design of the anchorage should be submitted for <br />review. See IBC Section 1604.1 and 1604.4. <br />Continuing with the previous comment, the anchorage design should be suitable to the base material. It is <br />noted that the URM appears to potentially have a wood fagade. The fagade should be considered as a surface <br />finishing and not used to support the sign. Furthermore, the anchorage should consider that the masonry is <br />likely not in like -new condition and has reduced structural integrity. Appropriate material properties <br />considering the age and condition of the masonry should be determined. The anchorage design should comply <br />with the procedures of TMS 402-16. See IBC Section 2101.2. <br />3. Wind loads should be determined per ASCE 7-16 Chapter 26 and applied concurrently using the appropriate load <br />combinations per IBC Section 1605. See IBC Section 1609.1. <br />Please contact me if you have questions. Thank you. <br />— Drew Martin, P.E., S.E. <br />Associate Engineer —Commercial Plans Examiner I Permit Services <br />425.257.8810 13200 Cedar Street, 2nd Floor, Everett, WA 98201 <br />EVERETT Phone Hours: M/W/T: 8 am - 12 pm & 1 pm — 3 pm; Tu: 1:00pm-3:00pm <br />everettwa.gov/permits I Facebook I Twitter <br />Note: Emails and attachments sent to and from the City of Everett are public records and may be subject to disclosure pursuant to the Public <br />Records Act. <br />
The URL can be used to link to this page
Your browser does not support the video tag.