Laserfiche WebLink
ESR-4143 I Most Widely Accepted and Trusted Page 14 of 82 Page 2 of 20 <br />(AISI 304 or 316), Condition CW. Threaded steel rods must <br />be straight and free of indentations or other defects along <br />their lengths. The ends may be stamped with identifying <br />marks and the embedded end may be blunt cut or cut on the <br />bias (chisel point). <br />3.2.4 Steel Reinforcing Bars (For Use in Fully Grouted <br />Concrete Masonry): Steel reinforcing bars are deformed <br />reinforcing bars (rebar) having diameters described in <br />Tables 3A, 313, 513, 5D, and 11 of this report, and must <br />comply with ASTM A615, Grade 60. The embedded portions <br />of reinforcing bars must be straight, and free of mill scale, <br />rust, mud, oil, and other coatings that impair the bond with <br />the adhesive <br />3.2.5 HIT -SC Screen Tubes: The Hilti HIT -SC <br />plastic -mesh screen tubes are used in hollow masonry as <br />described in Sections 3.4, 3.5, and 5.6 of this report. The <br />screens consist of a removable cap, a collar, and a plastic <br />mesh tube. <br />3.2.6 HIT -IC Inserts (For Use With Plastic Mesh <br />Screens in Hollow Masonry): Hilti HIT -IC are steel <br />internally threaded inserts conforming to DIN 10277-3 and <br />are available in 5/16-, 3/8-, and 1/2-inch (7.9, 9.5, and <br />12.7 mm) internal thread diameters. Common threaded rods <br />as per Section 3.2.3, or bolts, cap screws, and studs <br />conforming to SAE J995, ASTM A563 C, C3, D, DH, DH3 <br />Heavy Hex, and ASTM F594, can be used with internally <br />threaded inserts. <br />3.2.7 HIS-N and HIS -RN Inserts (For Use in Fully <br />Grouted Concrete Masonry): Hilti HIS-(R)N steel inserts <br />have a profile on the external surface and are internally <br />threaded. Inserts are available in 3/8- and 1/2-inch (9.5 and <br />12.7 mm) internal thread diameters. HIS-(R)N inserts are <br />produced from carbon steel and furnished either with a <br />0.005-millimeter-thick (5 mm) zinc electroplated coating <br />complying with ASTM B633 SC 1 or a hot -dipped galvanized <br />coating complying with ASTM A153, Class C <br />or D. The stainless steel HIS -RN inserts conform to <br />DIN 10088-3. Common threaded rods as per Section 3.2.3, <br />or bolts, cap screws, and studs conforming to SAE J995, <br />ASTM A563 C, C3, D, DH, DH3 Heavy Hex, and ASTM <br />F594 can be used with internally threaded inserts. <br />3.3 Fully Grouted Concrete Masonry: Fully grouted <br />concrete masonry must comply with Chapter 21 of the IBC. <br />The compressive strength of masonry, fm, at 28 days must <br />be a minimum of 1,500 psi (10.3 MPa). Fully grouted <br />masonry systems must be constructed from the following <br />materials: <br />3.3.1 Concrete Masonry Units (CMUs): CMUs must <br />be minimum Grade N, Type 1, light-, medium-, or <br />normal -weight conforming to ASTM C90. The minimum <br />nominal size of the CMUs must be 8 inches wide by <br />8 inches high by 16 inches long. <br />3.3.2 Grout: Grout must comply with 2018 and 2015 IBC <br />Section 2103.3, 2012 IBC Section 2103.13, and 2009 IBC <br />Section 2103.12, or 2018 IRC Section R606.2.12, 2015 IRC <br />Section R606.2.11, 2012 and 2009 IRC Section R609.1.1, <br />as applicable. Alternatively, the grout must have a minimum <br />compressive strength, when tested in accordance with <br />ASTM C1019, equal to its specified strength, but not less <br />than 2,000 psi (13.8 MPa). <br />3.3.3 Mortar: Mortar must be Type N (minimum) in <br />accordance with IBC Section 2103, or 2018 IRC Section <br />R606.2.8, 2015 IRC Section R606.2.7, or 2012 and 2009 <br />IRC Section R607, as applicable. <br />3.4 Hollow (Ungrouted) Concrete Masonry: Hollow <br />concrete masonry must comply with Chapter 21 of the IBC. <br />The compressive strength of masonry, fm, at 28 days must <br />be a minimum of 1,500 psi (10.3 MPa). Hollow concrete <br />masonry walls must be constructed from the following <br />materials: <br />3.4.1 Concrete Masonry Units (CMOs): CMUs must <br />be minimum Grade N, Type 1, light-, medium-, or <br />normal -weight conforming to ASTM C90. The minimum <br />nominal size of the CMUs must be 8 inches wide by <br />8 inches high by 16 inches long. <br />3.4.2 Mortar: Mortar must be Type N (minimum) in <br />accordance with IBC Section 2103, or 2018 IRC Section <br />R606.2.8, 2015 IRC Section R606.2.7 or 2012 and 2009 <br />IRC Section R607, as applicable. <br />3.5 Hollow Brick Masonry: Hollow brick masonry must <br />comply with Chapter 21 of the IBC. The compressive <br />strength of masonry, fm, at 28 days must be a minimum of <br />3,000 psi (20.7 MPa). Hollow brick masonry walls must be <br />a minimum of two-wythes in thickness, and constructed from <br />the following materials: <br />3.5.1 Brick Masonry Units: Hollow brick masonry must be <br />constructed using hollow bricks conforming to ASTM C652, <br />Grade SW. The minimum nominal size of the brick masonry <br />units must be 35/8 inches (92 mm) wide by <br />21/4 inches (57 mm) high by 75/8 inches (194 mm) long. <br />3.5.2 Mortar: Mortar must be Type N (minimum) in <br />accordance with IBC Section 2103, or 2018 Section <br />R606.2.8, 2015 Section R606.2.7 or 2012 and 2009 IRC <br />Section R607, as applicable. <br />4.0 DESIGN AND INSTALLATION <br />4.1 Design: <br />4.1.1 General: Anchors described in this report are <br />assigned allowable tension and shear load values based on <br />allowable stress design (ASD), as an alternative to Section <br />8.1.3 (2018 or 2013 editions) or Section 2.1.4 (2011, 2008 <br />or 2005 editions) of TMS 402/ ACI 530/ ASCE 5, as <br />applicable, as referenced in Section 2107 of the IBC. For <br />use under the IRC, an engineered design in accordance <br />with Section R301.1.3 must be submitted to the code official. <br />The allowable tension and shear values reported herein <br />must be adjusted in accordance with Figure 1 for in-service <br />base -material temperatures in excess of 70°F (21'C). <br />Anchors installed or cured at temperatures below 23°F (- <br />5°C) are outside the scope of this report. Allowable tension <br />and shear loads based on steel strength for threaded rods <br />are described in Table 10, and for reinforcing bars are <br />described in Table 11. <br />Allowable stress design tension and shear load values in <br />Tables 3A, 313, 5A, 513, 5C and 5D may be used for <br />resistance to short-term loads such as wind and seismic, in <br />accordance with Section 5.5 and Table 2 of this report. Use <br />of the values in the remaining tables for seismic loads is <br />beyond the scope of this report. Use of the values in the <br />remaining tables may be used for short-term loading due to <br />wind forces; however, the allowable loads must not be <br />increased. <br />4.1.2 Combined Loading: Allowable loads for anchors <br />installed in masonry and subjected to combined tension and <br />shear forces must be determined by the following formula: <br />('Pt)" <br />+ \ VtJn 1.0 <br />where: <br />PS = Applied service tension load (Ibf or kN). <br />Pt = Allowable service tension load (Ibf or kN). <br />Vs = Applied service shear load (Ibf or kN). <br />