My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2925 WETMORE AVE CAFE UU 2023-10-25
>
Address Records
>
WETMORE AVE
>
2925
>
CAFE UU
>
2925 WETMORE AVE CAFE UU 2023-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 2:42:59 PM
Creation date
9/18/2023 7:43:20 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2925
Tenant Name
CAFE UU
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Drew Martin <br />From: Drew Martin <br />Sent: Thursday, May 25, 2023 3:01 PM <br />To: CJ Williams <br />Subject: City of Everett Permit Services; 2925 Wetmore Avenue (52303-001) - Third Building <br />Review <br />Good afternoon, CJ. <br />This email recaps our conversation regarding documentation that needs to be submitted for review. As discussed, a <br />revised engineering detail is also required. Revised documents should be uploaded to the City of Everett permitting <br />application. <br />Please address the following: <br />1. Submit revised construction drawings including structural details. <br />2. The FOR has not addressed the design of the sign using the proper wind loading procedure as stated in previous <br />comments. Additional action is not being required for this comment; this issue is being stated for posterity. <br />3. The detail specifies a %" rod with an embedment in the masonry of 2". The connection should also specify the <br />HIT -SC sieve sleeve. The embedment depth should be noted to not include the stucco thickness. <br />4. The drawings should specify continuous special inspection to be performed for the anchor installation by a <br />qualified special inspector per IBC Chapter 17. <br />5. The groove weld between the sign plates and mounting plate does not appear to comply with the prequalified <br />weld connections of AISC 360. Specifically, the end -butting of the two plates is anticipated to yield only a partial <br />groove weld of inadequate thickness and will experience burn -out the edge of the mounted plates. The weld <br />should be revised. It is recommended that the mounting plate extend past the sign plates. Special inspection <br />should be specified for the welding of the steel connections per IBC Chapter 17. <br />6. Continuing with the previous comment, the proposed weld has minimal flexural capacity. The heavy weight of <br />the sign, eccentric center -of -gravity, and cantilever length of the sign plates with result in flexural loading in the <br />plate and weld. The welds are prone to sudden brittle failure. Stiffener plates should be provided between the <br />sign and mount plates to eliminate flexure in the welds. Alternatively, calculations substantiating the flexural <br />capacity of the plates and welds should be submitted for review. The effective depth of the welds for strength <br />should be limited based on the appropriate prequalified weld per AISC 360; the prequalified weld used be <br />specified in the detail and calculations for reference. <br />Thank you. <br />— Drew Martin, P.E., S.E. <br />Associate Engineer —Commercial Plans Examiner I Permit Services <br />425.257.8810 13200 Cedar Street, 2nd Floor, Everett, WA 98201 <br />EVERETT Phone Hours: M/W/T: 8 am - 12 pm & 1 pm — 3 pm; Tu: 1:OOpm-3:OOpm <br />everettwa.gov/permits I Facebook I Twitter <br />Note: Emails and attachments sent to and from the City of Everett are public records and may be subject to disclosure pursuant to the Public <br />Records Act. <br />
The URL can be used to link to this page
Your browser does not support the video tag.