Laserfiche WebLink
7 of 32 <br />Hilti PROMS Engineering 3.0.85 <br />www.hilti.com <br />Company: Page: 4 <br />Address: Specifier: <br />Phone I Fax: E-Mail: <br />Design: Drafts_39451-3-HILTI (1) Date: 4/28/2023 <br />Fastening point: <br />3 Tension load (Most utilized anchor 1) <br />Load PS [lb] Capacity Pt [lb] Utilization Pp = Ps/Pt [%] Status <br />Steel strength <br />80 <br />2,115 4 OK <br />Bond strength <br />80 <br />112 72 OK <br />3.1 Steel strength <br />Pts = Value <br />refer to Hilti Technical Data <br />Pts > Ps <br />Results <br />Pt,s [lb] <br />Ps [lb] <br />2,115 <br />80 <br />3.2 Bond strength <br />Pt,b,Base = Value <br />refer to Hilti Technical Data <br />Pt,b = Pt,b,Base <br />fred,E fred,s fred,Temp <br />Pt,b > Ps <br />Variables <br />cmin [in.] <br />cor [in.] <br />Smin [in.] <br />Scr [in.] <br />Temperature [°F] <br />8.000 <br />16.000 <br />8.000 <br />16.000 <br />68 <br />Results <br />Ptb [lb] <br />Ptb,Base [lb] <br />Ps [lb] <br />fmd,E <br />fred,s fred,Temp <br />112 <br />895 <br />80 <br />0.250 <br />0.500 1.000 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROMS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />4 <br />