My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2701 ROCKEFELLER AVE 2024-03-05
>
Address Records
>
ROCKEFELLER AVE
>
2701
>
2701 ROCKEFELLER AVE 2024-03-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2024 2:25:48 PM
Creation date
9/19/2023 6:53:36 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
2701
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
186
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WATER PURVEYOR: <br />® SMITH FIRE SYSTEMS <br />�� RD!! � BACKFLOW PREVENTION ASSEMBLY TEST REPORT <br />1106 54th Avenue East, Tacoma, WA 98424 <br />Phone: (253) 248-2000 Fax: (253) 248-2360 <br />ACCOUNT# <br />NAME OF PREMISE 2701 ROCKEFELLER AVE NC-18005 <br />SERVICE ADDRESS 2701 ROCKEFELLER AVENUE CITY EVERETT <br />CONTACT PERSON KEATS LUGINBILL PHONE 360-535-1078 <br />LOCATION OF ASSEMBLY RISER ROOM,,, NW CORNER OF LEVEL P1 <br />DOWNSTREAM PROCESS k) b o /'"t /-iI V ` DCVA ❑ RPBA ❑ PVBA ❑ OTHER _ <br />NEW INSTALL EXISTING❑ REPLACEMENT ❑ OLD SER. # PROPER INSTALaLlA.�TIIIOONJ?? YES / ' NO ❑ <br />MAKE OF ASSEMBLY WILKINS MODEL 350ASTDA SERIAL NO. J / U !✓ SIZE 4" <br />SEND TO: <br />Commercial J9 Residential ❑ <br />ZIP <br />FAX <br />DCVA <br />DCVA <br />RPBA <br />PVBA/SVBA <br />INITIAL <br />CHECK VALVE NO. 1 <br />CHECK VALVE NO.2 <br />AIR INLET <br />TEST <br />OPENED AT <br />PSID <br />PASSED <br />6 <br />❑ <br />LEAKED ❑ <br />2 <br />LEAKED ❑ <br />PSID <br /># 1 CHECK <br />AIR GAP OK? <br />PSID <br />OPENED AT <br />DID NOT OPEN <br />PSID <br />ElFAILED <br />NEW <br />PARTS <br />CLEAN REPLACE PAR -I <br />❑ ❑ <br />CLEAN REPLACE RART <br />❑ ❑ <br />CLEAN REPLACE <br />❑ ❑ <br />PART <br />CHECK VALVE <br />HELD AT PSID <br />LEAKED ❑ <br />AND <br />REPAIRS <br />❑ ❑ <br />❑ ❑ <br />❑ ❑ <br />❑ ❑ <br />❑ ❑ <br />❑ ❑ <br />❑ ❑ <br />❑ ❑ <br />❑ ❑ <br />_ <br />CLEANED <br />REPAIRED <br />❑ <br />❑ <br />TEST AFTER <br />REPAIRS <br />LEAKED ❑ <br />LEAKED ❑ <br />OPENED AT <br />PSID <br />AIR INLET <br />PSID <br />PASSED <br />❑ <br />PSID <br />SID <br />#I CHECK <br />PSID <br />CHK VALVE <br />PSID <br />FAILED ❑ <br />AIR GAP INSPECTION: Required minimum air gap separation provided? Yes ❑ No ❑ Detector Meter Reading <br />REMARKS LINE PRESSURE � PSI <br />EDITION TEST PROCEDURES AT SDOH APPROVED DEVICE? YES ❑ NO ❑ CONFINED SPACE? NO <br />Y <br />TESTERS SIGNATURE: ' CERT. NO. �� DATE =ZZ <br />f. <br />TESTERS NAME PRINTED• ° 1 TESTING COMPANY'S PHONE #: (253) 248-2000 <br />CALIBRATION DATE GAUGE # Q21 MODEL SERVICE RESTORED? YES❑ NO/6 <br />REPAIRED BY: CERT. NO.: DATE <br />FINAL TEST BY: CERT. NO.: DATE <br />CALIBRATION DATE GAUGE # MODEL SERVICE RE, STORED? YES❑ NOD <br />I certify that this report is accurate, and I have used wAC 46-290490 approved test methods and test equipment. <br />
The URL can be used to link to this page
Your browser does not support the video tag.