Laserfiche WebLink
I /!\ WARNING I <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />WARNING <br />THIS EQUIPMENT IS FED BY MULTIPLE <br />SOURCES. TOTAL RATING OF ALL <br />OVERCURRENT DEVICES, EXCLUDING <br />MAIN SUPPLY OVERCURRENT <br />DEVICE, SHALL NOT EXCEED <br />AMPACITY OF BUSBAR. <br />Di, WARNING <br />INVERTER OUTPUT CONNECTION <br />DO NOT RELOCATE THIS OVER <br />CURRENT DEVICE <br />I /[\ WARNING I <br />DUAL POWER SUPPLY <br />SOURCES: UTILITY GRID AND PV <br />SOLAR ELECTRIC SYSTEM <br />LABEL 1 <br />WHERE ALL TERMINALS OF THE DISCONNECTINGS <br />MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A <br />WARNING SIGN SHALL BE MOUNTED ON OR ADJACENT <br />TO THE DISCONNECTING MEANS. <br />[NEC 690.13(B) AND NEC 690.15(C) ] <br />LABEL 2 <br />PERMANENT WARNING LABELS SHALL BE APPLIED TO <br />DISTRIBUTION EQUIPMENT. <br />[NEC 705.12 (B) (3) (3)] <br />LABEL 3 <br />A PERMANENT WARNING LABEL SHALL BE <br />APPLIED TO THE DISTRIBUTION EQUIPMENT <br />ADJACENT TO THE BACK -FED BREAKER FROM <br />THE INVERTER. <br />[NEC 705.12 (B) (3) (2)] <br />LABEL 4 <br />EQUIPMENT CONTAINING OVERCURRENT <br />DEVICES IN CIRCUITS SUPPLYING POWER TO A <br />BUSBAR OR CONDUCTOR SUPPLIED FROM <br />MULTIPLE SOURCES SHALL BE MARKED TO <br />INDICATE THE PRESENCE OF ALL SOURCES <br />[NEC 705.101 <br />LABEL 5 <br />ALL INTERACTIVE SYSTEM(S) POINTS OF <br />INTERCONNECTION WITH OTHER SOURCES SHALL <br />BE MARKED AT AN ACCESSIBLE LOCATION AT THE <br />DISCONNECTING MEANS AS A POWER SOURCE <br />AND WITH THE RATED AC OUTPUT CURRENT AND <br />THE NOMINAL OPERATING AC VOLTAGE. <br />[NEC 690.541 <br />(1) BUILDINGS WITH MORE THAN ONE RAPID SHUTDOWN TYPE. FOR BUILDINGS THAT HAVE PV SYSTEMS <br />WITH BOTH RAPID SHUTDOWN TYPES OR A PV SYSTEM WITH A RAPID SHUTDOWN TYPE AND A PV SYSTEM <br />WITH NO RAPID SHUTDOWN, A DETAILED PLAN VIEW DIAGRAM OF THE ROOF SHALL BE PROVIDED SHOWING <br />EACH DIFFERENT PV SYSTEM AND A DOTTED LINE AROUND AREAS THAT REMAIN ENERGIZED AFTER THE RAPID <br />SHUTDOWN SWITCH IS OPERATED. <br />I ARFI INC; NnTFC- <br />1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT <br />REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. <br />2. LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI <br />Z535. <br />3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. <br />4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21(B)(3)] <br />5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND <br />PERMANENTLY AFFIXED [IFC 605.11.1.11 <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />SWICH TO THE "OFF" <br />PV PANELS <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN ARRAY <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />— — <br />POSITION TO SHUT DOWN <br />I — — — <br />CONDUCTORS OUTSIDE <br />THE ARRAY. CONDUCTORS <br />WITHIN THE ARRAY REMAIN <br />r� <br />lul <br />ENERGIZED IN SUNLIGHT <br />MAIN SERVICE PANEL <br />00 <br />0100 <br />O <br />(ONLY IF PV <br />INTERCONNECTION <br />CONSISTS OF LOAD <br />SIDE BREAKER) <br />I ARFI F <br />AT DIRECT -CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND <br />ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED <br />AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, <br />PARTITIONS, CEILINGS, OR FLOORS. <br />[NEC 690.31(G)(3&4)] <br />LABEL 7 LABEL 10 <br />BUILDINGS WITH PV SYSTEMS SHALL HAVE A PERMANENT <br />LABEL LOCATED AT EACH SERVICE EQUIPMENT LOCATION <br />TO WHICH THE PV SYSTEMS ARE CONNECTED OR AT AN <br />APPROVED READILY VISIBLE LOCATION AND SHALL INDICATE <br />THE LOCATION OF RAPID SHUTDOWN INITIATION DEVICES. <br />THE LABEL SHALL INCLUDE A SIMPLE DIAGRAM OF A BUILDING <br />WITH A ROOF AND SHALL INCLUDE THE FOLLOWING WORDS: <br />THE TITLE "SOLAR PV SYSTEM IS EQUIPPED WITH <br />RAPID SHUTDOWN" SHALL UTILIZE CAPITALIZED <br />CHARACTERS WITH A MINIMUM HEIGHT OF 3/8 IN. IN <br />BLACK ON YELLOW BACKGROUND, AND THE REMAINING <br />CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM <br />HEIGHT OF 3/16 IN. IN BLACK ON WHITE BACKGROUND. <br />[NEC 690.56 (B), 690.4 (D) AND 705.101 <br />LABEL 8 <br />FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS <br />LEAVING THE ARRAY: <br />SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY <br />FROM SERVICE DISCONNECTING MEANS TO WHICH THE <br />PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE <br />LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN <br />SWITCHES IF NOT AT THE SAME LOCATION. <br />[NEC 690.56 (C) (1) (B)] <br />LABEL 9 <br />A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL <br />LOCATED ON OR NO MORE THAN 3 FT FROM THE SWITCH <br />THAT INCLUDES THIS WORDING. THE LABEL SHALL BE <br />REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A <br />MINIMUM HEIGHT OF 3/8 IN., IN WHITE ON RED <br />BACKGROUND. <br />[NEC 690.56 (Q] <br />EXISTING SUB PANEL <br />(IF WHERE POINT OF <br />INTERCONNECTION <br />IS MADE) <br />00 <br />00 <br />O <br />(ONLY IF PV <br />INTERCONNECTION <br />CONSISTS OF LOAD <br />SIDE BREAKER) <br />LABELING DIAGRAM: <br />AC DISCONNECT <br />O 00 <br />Oo <br />PV COMBINER <br />SUBPANEL- <br />IF USED TO COMBINE <br />PV OUTPUT CIRCUITS <br />O <br />O <br />O <br />O <br />P <br />H 0 T <br />0 <br />V 0 L <br />T A I C <br />AC <br />DISC <br />0 N <br />N E <br />EACH PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY <br />INDICATE WHETHER IN THE OPEN (OFF) OR CLOSED (ON) <br />POSITION AND BE PERMANENTLY MARKED: <br />"PV SYSTEM DISCONNECT" OR EQUIVALENT. <br />[NEC 690.13(B), 690.15 AND 705.201 <br />INVERTER (S) <br />%DC <br />000 <br />O <br />INTEGRATED DC DISCONNECT <br />JUNCTION BOX <br />OR COMBINER BOX <br />O <br />O <br />*ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS <br />PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE. <br />Revolution Energy Systems Inc. <br />9981 West 190th St <br />Unit K Mokena IL 60448 <br />T: 708-995-1643 <br />SITE INFORMATION <br />CORINNE SHEARER <br />1929 75TH STREET SE <br />EVERETT, WA 98203 <br />AC System Size: 10.40 kW AC / 10.40 kVA <br />DC System Size: 14.40 kW DC <br />Lat, 47.9307418 <br />Long,-122.2057984 <br />(32) CANADIAN SOLAR CS3W-450MS (450W) <br />PV Modules <br />(32) ENPHASE IQ8M-72-2-US (240V) <br />Inverter(s) <br />SNOHOMISH COUNTY PUD <br />DRAWN BY: JEROME JAPAL <br />DATE: <br />4/27/2023 <br />LABELS - PV07 <br />