Page 2 of 2 <br /> D. Solar Panel Anchorage <br /> 1. The solar panels shall be mounted in accordance with the most recent Sunmodo installation <br /> manual. If during solar panel installation,the roof framing members appear unstable or deflect non- <br /> uniformly, our office should be notified before proceeding with the installation. <br /> 2. The maximum allowable withdrawal force for a 5/16" lag screw is 235 lbs per inch of penetration as <br /> identified in the National Design Standards (NDS) of timber construction specifications. Based on <br /> a minimum penetration depth of 2'/2", the allowable capacity per connection is greater than the <br /> design withdrawal force (demand). Considering the variable factors for the existing roof framing <br /> and installation tolerances, the connection using one 5/16" diameter lag screw with a minimum of <br /> 2'/2" embedment will be adequate and will include a sufficient factor of safety. <br /> 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of <br /> the roof, the panel supports shall be placed no greater than 48" on center. <br /> 4. Panel supports connections shall be staggered to distribute load to adjacent framing members. <br /> Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing <br /> roof system will adequately support the additional loading imposed by the solar system. This evaluation is in <br /> conformance with the Washington State Residential Code, current industry standards, and is based on <br /> information supplied to us at the time of this report. <br /> Should you have any questions regarding the above or if you require further information do not hesitate to <br /> contact me. <br /> V <br /> truly yours, <br /> Scott E.Wyssli PE <br /> Washington License 111163 <br /> W <br /> GOA s <br /> G� <br /> H ' <br /> � � 20111163 40� <br /> �t<` �01STE4�O ��' <br /> ss�O.NAL r-'- <br /> Signed <br /> NSigned 10/27/2022 <br /> CONSULTING <br />
The URL can be used to link to this page
Your browser does not support the video tag.