STRING CALCULATIONS SYSTEM OCPD CALCULATIONS <br /> ENPHASE:IQ8M-72-2-US(240V) STRING#1 STRING#2 INVERTER MODEL(S): EN PHASE IQ8M-72-2-US(240V) <br /> MAX AC CURRENT 14A 14A #OF INVERTER(S): 17 <br /> MICRO INVERTER(S)IN SERIES: 9 8 MAX OUTPUT CURRENT: 1.35A <br /> NOMINAL VOLTAGE/RANGE 211V-264V 211V-264V (#OF INVERTERS)X(MAX OUTPUT CURRENT)X 125%<=OCPD RATING <br /> MAX AC OUTPUT POWER: 2763W 2763W (17 X 1.35A X 1.25)=28.78A<=30A,OK <br /> ARRAY DC POWER: 8160W S L A R <br /> BUSBAR CALCULATIONS-120%RULE <br /> TOTAL MAX AC CURRENT: 23.02A MAIN BUS BAR RATING: 200A <br /> Revolution Energy Systems Inc. <br /> NUMBER OF CURRENT CARRYING CONDUCTORS PERCENT OF VALUES MAIN DISCONNECT RATING: 200A <br /> 4-6 .80 PV OCPD RATING: 30A 9981 West 190th St <br /> 7-9 .70 PV OCPD RATIN(IMAIN BUS RATING X 120%)-MAIN DISCONNECT RATING>=OCPD RATING Unit K Mokena IL 60448 <br /> 10-20 .50 (200A X 1.2)-200A=40A,>=30A,OK T: 708-995-1643 <br /> Conduit&Conductor Schedule <br /> TAG QTY WIRE GAUGE DESCRIPTION CONDUIT SIZE CONDUCTOR RATING CONDUCTOR TEMP.RATE AMBIENTTEMP TEMP.DERATE #OF CONDUCTORS CONDUCTOR RATING CONDUIT FILL <br /> DERATE W/DERATES <br /> 1 (2) 10 AWG Q-CABLE,COPPER(L1,L2) N/A-FREE AIR 40A 90°C 26°C 1.0 N/A-FREE AIR 40A N/A-FREE AIR <br /> (1) 6 AWG THWN-2 COPPER-(GROUND) <br /> SITE INFORMATION <br /> (2) 10 AWG THHN/THWN-2,COPPER-(Ll,L2) <br /> 2 3/4"EMT 40A 90°C 26°C 1.0 1.0 40A 11.45% BARBARA F BOOP <br /> (1) 10 AWG THWN-2 COPPER-(GROUND) <br /> (4) 10 AWG THHN/THWN-2,COPPER-(L1,L2) 1510 108TH ST SW <br /> 3 3/4"EMT 40A 90°C 26°C 1.0 0.8 32A 19.09 <br /> (1) 10 AWG THWN-2 COPPER-(GROUND) EVERETT,WA 98204 <br /> 4 (3) 10 AWG THHN/THWN-2,COPPER-(L1,L2,NEUTRAL) 3/4"EMT 40A 90°C 26°C 1.0 1.0 40A 15.27% AC System Size:5.53 kW AC/5.53 kVA <br /> (1) 10 AWG THWN-2 COPPER-(GROUND) <br /> DC System Size:8.16 kW DC <br /> 5 (3) 10 AWG THHN/THWN-2,COPPER-(L1,L2,NEUTRAL) 3/4"EMT 35A 75°C 26°C 1.0 1.0 35A 15.27 <br /> Lat,47.8999410 <br /> (1) 10 AWG THWN-2 COPPER-(GROUND) <br /> Long,-122.2542824 <br /> (17) HANWHA Q.PEAK DUO XL-G10.2 480 <br /> PV Modules <br /> (17) ENPHASE IQ8M-72-2-US(240V) <br /> Inverter(s) <br /> SNOHOMISH PUD <br /> GROUNDING&GENERAL NOTES: INTERCONNECTION NOTES: <br /> 1. PV INVERTER IS UNGROUNDED,TRANSFORMER-LESS TYPE. 1. INTERCONNECTION SIZING,LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC <br /> 2. DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE 705.12],AND[NEC 690.64]. <br /> 2.GROUND FAULT PROTECTION IN ACCORDANCE WITH[NEC 215.9],[NEC 230.95]AND[NEC 690.5] <br /> 3.ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO 3.ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. <br /> BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. <br /> 4.JUNCTION BOX QUANTITIES,AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD- <br /> JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE DISCONNECT NOTES <br /> TRANSITIONS. 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS <br /> 5.AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED"LINE SIDE"(TYPICALLY THE UPPER TERMINALS) DRAWN BY: M. MONTEMOR <br /> AC DISCONNECTING MEANS IS LOCATED WITHIN 10'OF SERVICE DISCONNECT. 2.AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE,AND BE A DATE: <br /> VISIBLE-BREAK SWITCH 12/1/2022 <br /> ELECTRICAL CALCS- PV06 <br />
The URL can be used to link to this page
Your browser does not support the video tag.