My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9027 9TH PL W 2023-10-19
>
Address Records
>
9TH PL W
>
9027
>
9027 9TH PL W 2023-10-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2023 9:28:14 AM
Creation date
9/20/2023 6:24:11 AM
Metadata
Fields
Template:
Address Document
Street Name
9TH PL W
Street Number
9027
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SCOPE OF WORK GOVERNING CODES SYSTEM RATING PHOTOVOLTAIC SYSTEM FIRE <br /> TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE CLASSIFICATION LISTING IN 000 kWDC 18. Lumio <br /> LOCATED AT 9027 9TH PL W, EVERETT, WA 98204, USA. 2018 INTERNATIONAL FIRE CODE ACCORDANCE WITH UL 1703 <br /> THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY 2018 INTERNATIONAL BUILDING CODE 13.500 kWAC STANDARD. <br /> GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. 2018 INTERNATIONAL RESIDENTIAL CODE LUMIO <br /> 2020 NATIONAL ELECTRICAL CODE SHEET INDEX 1550 DIGITAL DR,LEHI,UT <br /> THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. WASHINGTON ADMINISTRATIVE CODE (WAC) 84043,USA <br /> PV1 COVER PAGE <br /> EQUIPMENT SUMMARY I AHJ NAME : EVERETT CITY PV2 SITE PLAN <br /> 45 Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES WIRING AND CONDUIT NOTES PV3 ROOF PLAN <br /> 45 ENPHASE IQ8PLUS-72-2-US (240V) MICROINVERTERS • ALL CONDUIT SIZES AND TYPES SHALL BE LISTED FOR ITS PURPOSE AND PV4 STRING LAYOUT&BOM <br /> APPROVAL FOR THE SITE APPLICATIONS <br /> GENERAL NOTES - ALL <br /> ATTACHMENT DETAILS <br /> CABLING <br /> • THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND ALL PV CABLES AND WIRES BE#1 ,USE 2, PV WIRE, OR PV7 ELECTRICAL LINE&CALCS. <br /> OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE PROPRIETARY SOLAR CABLING SPECIFIED BYYAWG MFR, OR EQUIVALENT; ROUTED TO SYSTEM INFO <br /> MODIFICATIONS IN CONSTRUCTION DETAILS. SOURCE CIRCUIT COMBINER BOXES AS REQUIRED PV8 SPECIFICATIONS&NOTES <br /> (45)Q CELLS <br /> ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE PV9-PV10 SIGNAGE Q.PEAK DUO BLK ML-G10+ <br /> • CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL DERATED ACCORDING TO AS PER LATEST NEC CODE. (40OW) <br /> PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. PV11 JOB SAFETY PLAN <br /> EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV (45)ENPHASE <br /> • CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS RESISTANT,AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE PV12-PV19 EQUIPMENT SPECIFICATIONS IQ8PLUS SIZE:US(00 k <br /> AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER DC SYSTEM SIZE:18.000 WDC <br /> USED TO PROTECT WIRE FROM SHARP EDGES <br /> BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION AND PROJECT SITE AC SYSTEM SIZE:13.500 kWAC <br /> ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE • PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 <br /> CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 1000V AS PER <br /> COMPENSATION. APPLICABLE NEC <br /> • DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, FLOORS, • 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER <br /> ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE RevlsloNs <br /> CONTRACTOR AT NO ADDITIONAL COST. MEANS 1 DESCRIPTION DATE REV <br /> • THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND • ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION <br /> COMPLETION OF THE WORK WITH APPROVED MATERIALS. . VOLTAGE DROP LIMITED TO 2% <br /> • CONTRACTOR SHALL OBTAIN BULDING PERMIT. NO WORK TO START UNLESS BUILDING . AC CONDUCTORS>4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, <br /> PERMIT IS PROPERLY DISPLAYED. PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL-WHITE/GRAY <br /> • ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE r PROJECT NAME&ADDRESS <br /> WITH THE REQUIREMENTS OF THE NATIONAL BUILDING CODE, THE DEPARTMENT OF <br /> ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. , j► <br /> • IT 1 S ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL •- Q <br /> PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. +{ <br /> THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. <br /> • THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE <br /> LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. o <br /> N <br /> • THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS, _.�,,k�_,� 00 m o <br /> ETC.AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. ..� �� 00 p� <br /> • CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK. J`t ' Z � o <br /> w o <br /> ELECTRICAL NOTES HOUSE PHOTO SCALE:NTS ; <br />
The URL can be used to link to this page
Your browser does not support the video tag.