Laserfiche WebLink
SOLAR MODULE SPECIFICATIONS VOLTAGE RISE IN Q CABLE FROM THE MICROINVERTERS TO THE JUNCTION BOX �( <br /> MANUFACTURER/MODEL Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) Lumio <br /> VMP 37.13 V FOR BRANCH CIRCUIT #1 OF 12 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 1.01% LUIVIO <br /> IMP 10.77 A FOR BRANCH CIRCUIT #2 OF 11 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.55% 1550 DIGITAL DR,LEHI,UT <br /> 84043,USA <br /> VOC 45.3 V FOR BRANCH CIRCUIT #3 OF 11 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.55% <br /> ISC 11.14 A FOR BRANCH CIRCUIT #4 OF 11 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.55% <br /> TEMP. COEFF. VOC -0.27%/K VOLTAGE RISE FROM THE JUNCTION BOX 1 TO THE IQ COMBINER BOX 4C <br /> PTC RATING 376.55 W VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br /> MODULE DIMENSION 74"(L)x 41.1"(W) <br /> PANEL WATTAGE 400 w = (1.21 AMP X 12) X (0.00205 OHMS/FT) X (52 FTX 2) SYSTEM INFO <br /> = 14.52 AMPS X 0.00205 OHMS/FT) X 104 FT (45)QCELLS <br /> INVERTER SPECIFICATIONS Q.PEAK DUO BLK ML-G10+ <br /> MANUFACTURER/MODEL ENPHASE IQ8PLUS-72-2-US (240V) %VRISE = 3.10 VOLTS = 240 VOLTS = 1.29% (45)ENPHASE <br /> MAX DC SHORT CIRCUIT CURRENT 15 A IQ8PLUS-72-2-US(240V) <br /> CONTINUOUS OUTPUT CURRENT 1.21 A THE VOLTAGE RISE FROM THE JUNCTION BOX 1 TO THE IQ COMBINER BOX 4C IS 1.29% DC SYSTEM SIZE,18.000kWDC <br /> AMBIENT TEMPERATURE SPECS VOLTAGE RISE FROM THE IQ COMBINER BOX 4C TO THE FUSED AC DISCONNECT AC SYSTEM SIZE:13.500kWAC <br /> RECORD LOW TEMP -5°C VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br /> AMBIENT TEMP (HIGH TEMP 2%) 26°C = (1.21 AMP X 45) X (0.000321 OHMS/FT) X (5 FT X 2) REVISIONS <br /> CONDUIT HEIGHT 7/8" = 54.45 AMPS X 0.000321 OHMS/FT) X 10 FT DESCRIPTION DATE REV <br /> ROOF TOP TEMP 90°C = 0.17 VOLTS <br /> CONDUCTOR TEMPERATURE RATE 48°C %VRISE = 0.17 VOLTS - 240 VOLTS = 0.07% <br /> MODULE TEMPERATURE COEFFICIENT OF VOC -0.27%/K THE VOLTAGE RISE FROM THE IQ COMBINER BOX 4C TO THE FUSED AC DISCONNECT IS 0.07% <br /> PERCENT OF VALUES NUMBER OF CURRENT CARRYING VOLTAGE RISE FROM THE FUSED AC DISCONNECT TO THE MSP PROJECT NAME&ADDRESS <br /> CONDUCTORS IN EMT <br /> 0.80 4-6 VRISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br /> 0.70 7-9 = (1.21 AMP X 45) X (0.000321 OHMS/FT) X (5 FT X 2) Q <br /> 0.50 10-20 = 54.45 AMPS X 0.000321 OHMS/FT) X 10 FT U) <br /> = 0.17 VOLTS <br /> %VRISE = 0.17 VOLTS - 240 VOLTS = 0.07% NN <br /> THE VOLTAGE RISE FROM THE FUSED AC DISCONNECT TO THE MSP IS 0.07% 00 m 00 <br /> C) <br /> TOTAL SYSTEM VOLTAGE RISE FOR ALL WIRE SECTIONS 0Lu 0 0 1= o <br /> 1.01% + 1.29% + 0.07% + 0.07% = 2.44% w w a Li m <br /> p *k ao <br /> W w U w o <br /> w <br /> Q 3 <br /> of Z <br /> d a- Q <br /> 2 <br /> ti <br /> N <br /> O <br /> DATE:6/23/2023 <br /> SHEET NAME <br /> SPECIFICATIONS <br /> & NOTES <br /> SHEET SIZE <br /> ANSI B <br /> 11" X 17" <br /> SHEET NUMBER <br /> PV-8 <br />