My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2305 127TH PL SE 2023-12-11
>
Address Records
>
127TH PL SE
>
2305
>
2305 127TH PL SE 2023-12-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/11/2023 11:47:18 AM
Creation date
9/21/2023 7:04:45 AM
Metadata
Fields
Template:
Address Document
Street Name
127TH PL SE
Street Number
2305
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Title: <br /> Engineer: <br /> Project ID: <br /> Project Descr: <br /> Wood Column Project File:rafdal calcs.ec6 <br /> LIC#:KW-06016450,Build:20.22.5.16 QUANTUM CONSULTING ENGINEERS (c)ENERCALC INC 1983-202; <br /> DESCRIPTION: P1 - Kitchen Stud Post, 8ft <br /> Code References <br /> Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 <br /> Load Combinations Used :ASCE 7-16 <br /> General Information <br /> Analysis Method Allowable Stress Design Wood Section Name 4x6 <br /> End Fixities Top&Bottom Pinned Wood Grading/Manuf. Graded Lumber <br /> Overall Column Height 8 ft Wood Member Type Sawn <br /> 'it on-s;e=!= �s/culat;ons) Exact Width in Allow Stress Modification Factors <br /> Wood Species Hem-Fir 3.50 <br /> Wood Grade No.2 Exact Depth 5.50 in Cf or Cv for Bending 1.30 <br /> Area 19.250 inA2 Cf or Cv for Compressio 1.10 <br /> Fb+ 850.0 psi Fv 150.0 psi lx 48.526 inm Cf or Cv for Tension 1.30 <br /> Fb- 850.0 psi Ft 525.0 psi <br /> Fc-PrIl 1,300.0 psi Density 26.840 pcf ly 19.651 in 4 Cm:Wet Use Factor 1.0 <br /> Fc- Ct:Temperature Fad 1.0 <br /> Perp 405.0 psi <br /> Cfu:Flat Use Factor 1.0 <br /> E : Modulus of Elasticity... x-x Bending y-y Bending Axial Kf:Built-up columns 1.0 `ios 15.3.2 <br /> Basic 1,300.0 1,300.0 1,300.0 ksi Use Cr: Repetitive? No <br /> Minimum 470.0 470.0 Brace condition for deflection(buckling)along columns: <br /> X-X(width)axis: Unbraced Length for buckling ABOUT Y-Y Axis=8 ft,K <br /> Y-Y(depth)axis: Unbraced Length for buckling ABOUT X-X Axis=8 ft,K <br /> Applied Loads Service loads entered.Load Factors will be applied for calculations <br /> Column self weight included : 28.704 lbs* Dead Load Factor <br /> AXIAL LOADS . . . <br /> Floor Beam Reaction:Axial Load at 8.0 ft, D = 1.70, L= 3.360 k <br /> DESIGN SUMMARY <br /> Bending&Shear Check Results <br /> PASS Max.Axial+Bending Stress Ratio = 0.5649: 1 Maximum SERVICE Lateral Load Reactions.. <br /> Load Combination +D+L Top along Y-1 0.0 k Bottom along Y-Y 0.0 k <br /> Governing NDS Forumla Comp Only,fc/Fc' Top along X-> 0.0 k Bottom along X-X 0.0 k <br /> Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections... <br /> At maximum location values are. Along Y-Y 0.0 in at 0.0 ft above base <br /> Applied Axial 5.089 k for load combination: n/a <br /> Applied Mx 0.0 k-ft <br /> Applied My 0.0 k-ft Along X-X 0.0 in at 0.0 ft above base <br /> Fc:Allowable 467.993 psi for load combination:n/a <br /> Other Factors used to calculate allowable stresses... <br /> PASS Maximum Shear Stress Ratio= 0.0: 1 Bending Compression Tension <br /> Load Combination +0.60D <br /> Location of max.above base 8.0 ft <br /> Applied Design Shear 0.0 psi <br /> Allowable Shear 240.0 psi <br /> Load Combination Results <br /> Maximum Axial+Bending Stress Ratios Maximum Shear Ratios <br /> Load Combination C D C p Stress Ratio Status Location Stress Ratio Status Location <br /> D Only 0.900 0.359 0.1944 PASS 0.0 ft 0.0 PASS 8.0 ft <br /> +D+L 1.000 0.327 0.5649 PASS 0.0 ft 0.0 PASS 8.0 ft <br /> +D+0.750L 1.250 0.268 0.4612 PASS 0.0 ft 0.0 PASS 8.0 ft <br /> +0.60D 1.600 0.213 0.1106 PASS 0.0 ft 0.0 PASS 8.0 ft <br /> Maximum Reactions Note:Only non-zero reactions are listed. <br /> X-X Axis Reaction k Y-Y Axis Reaction Axial Reaction My-End Moments k-ft Mx-End Moments <br /> Load Combination @ Base @ Top @ Base @ Top @ Base ©Base @ Top @ Base @ Top <br /> D Only 1.729 <br /> +D+L 5.089 <br /> +D+0.750L 4.249 <br />
The URL can be used to link to this page
Your browser does not support the video tag.