STRUCTURAL STEEL NOTES: WEATHERPROOFING NOTES: ELECTRICAL NOTES: Spri nt)�* <br /> 1. ALL STEEL WORK SHALL BE IN ACCORDANCE WITH THE LATEST COITION OF THE ASC MANUAL OF STANDARD CONSTRUCTION SPECIFICATIONS FOR WIRELESS SITES 1. ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ANY/ALL ELECTRICAL WORK INDICATED. ANY/ALL CONSTRUCTION SHALL BE <br /> STEEL CONSTRUCTION. STEEL SECTIONS SHALL BE IN ACCORDANCE WITH ASTM AS INDICATED 3.6 WEATHERPROOFING CONNECTORS AND GROUND KITS: IN ACCORDANCE W/DRAWINGS AND ANY/ALL APPLICABLE SPECIFICATIONS. If ANY PROSLEMS ARE ENCOUNTERED BY COMPLYING <br /> BELOW: WITH THESE REQUIREMENTS. CONTRACTOR SHALL NOTIFY'CONSTRUCTION MANAGER'AS SOON AS POSSIBLE,AFTER THE <br /> A ALL CONNECTORS AND GROUND KITS SHALL BE WEATHERPROOFED USING BUTYL RUBBER WEATHERPROOFING AND DISCOVERY OF THE PROBLEMS,AND SHALL NOT PROCEED WITH THAT PORTION OF WORK,UNTIL THE'CONSTRUCTION MANAGER' <br /> W-SHAPES:ASTM A992,50 KSI TAPE.THIS INSTALLATION MUST BE DONE IN ACCORDANCE Y47H THE MANUFACTURER'S RECOMMENDATION OR AS HAS DIRECTED THE CORRECTIVE ACTIONS TO BE TAKEN. <br /> ANGLES, BARS CHANNELS: ASTM A36,36 KSI SHOWN ON THE CONSTRUCTION DRAWINGS (WHICHEVER IS GREATER). IF NO DIRECTION IS PROVIDED. <br /> HSS SECTIONS:ASTM 500, 46 KSI WEATHERPROOFING MUST BE DONE PER THE FOLLOWING INSTRUCTIONS. 2. ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND FAMILIARIZE HIMSELF WITH ANY/ALL CONDITIONS AFFECTING ELECTRICAL <br /> PIPE SECTIONS:ASTM A53-E, 35 KSI 1.THE COAXIAL CABLE CONNECTION OR GROUND KIT CAN BE ENCOMPASSED INTO COLO SHRINK AND COMPLETELY AND COMMUNICA71ON INSTALLATION AND MAKE PROVISIONS AS TO THE COST THEREOF.ALL EXISTING CONDITIONS OF ELECTRICAL 4dw <br /> EQUIP.,LIGHT FIXTURES, ETC.,THAT ARE PMT OF THE FINAL SYSTEM, SHALL BE VERIFIED BY THE CONTRACTOR,PRIOR TO THE <br /> 2. ALL EXTERIOR EXPOSED STEEL AND HARDWARE SHALL 8£ HOT DIPPED GALVANIZED. WRAPPED WITH 2 INCH WIDE ELECTRICAL TAPE OVERLAPPING EACH ROW BY APPROXIMATELY '.':'AND EXTENDING SUBMITTAL OF HIS BID, FAILURE TO COMPLY WITH THIS PARAGRAPH WILL IN NO WAY RELIEVE CONTRACTOR OF PERFORMING ALL <br /> 3. ALL WELDING SHALL BE PERFORMED USING E70XX ELECTRODES AND WELDING SHALL CONFORM PAST THE CONNECTION BY 7W0 INCHES AS DISCUSSED BELOW;OR WORK NECESSARY FOR A COMPLETE AND WORKING SYSTEM. GENERAL DYNAMICS <br /> TO NSC.WHERE FILLET WELD SIZES ARE NOT SHOWN,PROVIDE THE MINIMUM SI2E PER TABLE 2.THE COAXIAL CABLE CONNECTION OR GROUND MT CAN BE WRAPPED WITH LAYERS OF ELECTRICAL/BUTYL J. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC AND ALL CODES AND LOCAL <br /> J2.4 IN THE AISC "MANUAL OF STEEL CONSTRUCTION". PAINTED SURFACES SHALL BE TOUCHED RUBBER/ELECTRICAL TAPE AS DISCUSSED BELOW;OR ORDINANCES OF THE LOCAL POWER& TELEPHONE COMPANIES HAVING JURISDICTION AND SHALL INCLUDED BUT NOT BE LIMITED WIRELESS SERVICES <br /> UP. <br /> TO: <br /> 4. NON-STURCIJTRAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8'0 ASTM A 307 BOLTS 3.THE COAXIAL CABLE CONNECTION OR GROUND IDT CAN BE WRAPPED WITH TWO LAYERS OF 1.5 INCH WIDE <br /> SELF-AMALGAMATING TAPE COVERED WITH TWO LAYERS OF ELECTRICAL TAPE AS DISCUSSED BELOW, A. UL -- UNDERWRITERS LABORATORIES <br /> UNLESS NOTED OTHERWISE.. <br /> B. NEC -- NATIONAL ELECTRICAL CODE <br /> 5- FIELD MODIFICATIONS ARE TO BE COATED WITH ZINC ENRICHED PAINT. B. COLO SHRINK INSTALLATION PROCEDURE: C. NEMA -- NATIONAL ELECTRICAL MANUFACTURERS ASSOC. <br /> 0. OSHA -- OCCUPATIONAL SAFETY AND HEALTH ACT <br /> 1.REQUIRED MATERIAL: COLD SHRINK TUBE,SPACERS AS NEEDEDBUCK ELECTRICAL TAPE-2 INCHES WIDE. E, IBC -- INTERNATIONAL BUILDING CODE <br /> STRUCTURAL CONCRETE NOTES: F. NFFA --, NATIONAL FIRE CODES JINGINEERING <br /> 2,REQUIRED TOOLS: KNIFE AND TAPE MEASURE 4. DO NOT SCALE ELECTRICAL DRAWINGS.REFER TO SITE PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT, AND <br /> 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301-05,ACI 318-05 AND THE FR�YfFIT IKFiR\{1TIC`\: <br /> SPECIFICATION FOR CAST-IN-PUCE CONCRETE. STEP 1: THOROUGHLY CLEAN AND DRY THE SURFACE OF COAXIAL CABLE AND CONNECTOR TO REMOVE ALL CONFIRM WITH 'CONSTRUCTION MMAOER'ANY SIZES AND AND LOCATIONS WHEN NEEDED. <br /> 2. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH He'-3,000 PSI AT 28 DAYS GREASE AND DIRT. MARK THE MAIN FEED (LARGER DIAMETER) COAXIAL CABLE AT LUST TWO INCHES ABOVE THE 5. EXISTING SERVICES: CONTRACTOR SHALL NOT INTERRUPT EXISTING SERVICES WITHOUT WRITTEN PERMISSION OF THE OWNER. NLI"01I VISKINI N4\1060LINCII <br /> UNLESS NOTED OTHERWISE. CONNECTION AS THE SPECIFIED START DIMENSION FOR THE COLD SHRINK. <br /> TIN AN TIM CONTRACTOR I5 TO OBTAIN PERMITS AND <br /> STEP 2: SLIDE THE COLD SHRINK TUBE OVER THE PRE THE CONNECTION. <br /> END OF THE LARGER DIAMETER COAXIAL 6' AP ROVED SUBMITTALS PRIOR TO THE WORK PERMITS, <br /> OR ORDERING EQUIPMENT.C <br /> 3. OTHERWISE. <br /> STEEL SHALL CONFORM LL ASTM A 615, GRADE 60,DEFORMED UNLESS NOTED CASTE PRIOR TO MATING CONNECTOR INTERFACES. MANE THE CONNECTION. Bl�-OAD Y 7 AY <br /> OTHERWISE.EDWELDED TH WIRE FABRIC SHALL CONFORM TO ASTM A 185 WELDED STEEL WIRE FABRIC STEP 3: REMOVE WAX PAPER FROM A SPACER HALF AND PRESS ONTO COAXIAL CABLE DIRECTLY BEHIND THE 7. THE TERM 'PROVIDE"USED IN CONSTRUCTION DOCUMENTS AND SPECIFICATIONS.INDICATES THAT THE CONTRACTOR SHALL <br /> UNLESS NOTED OTHERWISE. SPLICES CLASS 'B'AND ALL HOOKS SHALL BE STANDARD UNLESS <br /> NOTED OTHERWISE. CONNECTOR. REMOVE THE WAX PAPER FROM THE OTHER SPACER HALF AND ALIGN THE TWO SPACER HALVES WITH FURNISH AND INSTALL. !2 _ ) l <br /> ADHESIVE PORTIONS FACING EACH OTHER. PRESS THE SPACER HALVES TOGETHER. THE SPACER WILL BE PLACED SEC�3XL2O9 <br /> 4, THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS NEXT TO THE CONNECTOR ON THE SMALLER DIAMETER COAXIAL CABLE SIDE. 8. CONTRACTOR SHALL CONFIRM WITH LOCAL UTILITY COMPANY MY/ALL REQUIREMENTS SUCH AS THE: LUG SIZE RESTRICTIONS, <br /> SHOWN OTHERWISE ON DRAWINGS: STEP 4:SLIDE THE COLD SHRINK TUBE OVER THE CONNECTION TO THE SPECIFIED START DIMENSION MARK. HOLD CONDUIT ENTRY, SIZE OF TRANSFORMERS, SCHEDULED DOWNTIME FOR THE OWNERS'CONFIRMATION. ETC, ANY/ALL CONFLICTS 25.7 HOWARD AVF <br /> THE COLD SHRINK TUBE AND COAXIAL CABLE IN ONE HAND SO THAT THE EDGE OF COLD SHRINK TUBE 15 IN SHALL HE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER, PRIOR TO BEGINNING ANY WORK. <br /> CONCRETE CAST AGAINST EARTH...............3 IN. LINE WITH THE MARK. 9. MINIMUM WIRE SIZE SHALL BE 112 AWC, NOT INCLUDING CONTROL WIRING, UNLESS NOTED OTHERWISE.ALL CONDUCTORS SHALL EVERETT, WA 98203 <br /> CONCRETE EXPOSED TO EARTH OR WEATHER STEP 5: WITH YOUR FREE HMD, BEGIN REMOVING COLO SHRINK TUBE CORE. THE CORE WILL BE REMOVED BY BE COPPER WITH THWN INSULATION. SNOHOM'SH COUNTY <br /> /6 AND LARGER...............2 IN. UNWINDING IN A COUNTERCLOCKWISE DIRECTION WHILE LIGHTLY PULLING THE ATTACHED CORD AWAY FROM THE <br /> $5 AND SMALLER&WWF...............1 1/2 IN. TUBE' 10, OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET/DAMP LOCATIONS AND <br /> STEP 6: USE BOTH HANDS TO CONTINUE THE UNWINDING PROCESS AS THE COLD SHRINK TUBE BEGINS TO SPECIAL ENCLOSURES FOR OTHER CLASSIFIED MEAS, <br /> CONCRETE NOT EXPOSED TO EARTH OR WEATHER OR NOT CAST AGAINST THE GROUND: COLLAPSE INTO POSITION. CONTINUE THE UNWINDING PROCESS UNTIL THE CORE IS COMPLETELY REMOVED AND THAT IF IJ NI F: 07-30-12 <br /> � <br /> SLAB AND WALL...............3/4 IN. THE COLD SHRINK TUBE IS INSTALLED. 11. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF THE CONSTRUCTION. CONTRACTOR 15 V 7-30-1 2 <br /> BEAMS AND COLUMNS.- 1 1/2 IN. EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS FOR <br /> STEP 7: EXCESS COLD SHRINK TUBE EMENDING TWO INCHES BEYOND THE SPACER HALVES CAN 8E REMOVED OR THE EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. <br /> 5. A 3/4'CHAMFER SHALL BE PROVIDED AT ALL EXPOSED CODES OF CONCRETE U.N.O. IN LEFT IN PUCE. EXCESS COLD SHRINK TUBE CAN BE CAREFULLY CUT OFF WITH A KNIFE. ISSUI.I)F-L�R: I <br /> ACCORDANCE WITH ACI 301 SECTION 4.2.4 STEP 8: WRAP OVER THE COLD SHRINK TUBE WITH ONE LAYER OF BUCK ELECTRICAL TME 2 INCH WIDTH 12. ELECTRICAL SYSTEM SHALL BE AS COMPLETELY AND EFFECTIVELY GROUNDED,AS REQUIRED BY SPECIFICATION,SET FORTH BY ZON-NG/PERMITTING <br /> OVERLAPPING EACH ROW BY 1/2 INCH. THIS TOP LAYER MUST BE WRAPPED USING A SHINGLED EFFECT. THE SPRINT. <br /> 6. HOLES TO RECEIVE EXPANSION/WEDGE ANCHORS SHALL BE 1/8'LARGER IN DIAMETER THAN THE LAYER SHALL BE WRAPPED SO THAT THE ENDS ARE IN THE UPWARD DIRECTION CREATING A SHINGLED EFFECT 13, ALL WORK SHALL BE PERFORMED BY A UCENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS, WORKMANLIKE MANNER.THE REVISIONS <br /> ANCHOR BOLT, DOWEL OR ROD AND SHALL CONFORM 10 MANUFACTURER'S RECOMMENDATION FOR WITH THE TME SO WATER WILL BE REPELLED AND NOT ALLOWED TO COLLECT AND POOL, THIS TOP LAYER OF COMPLETED SYSTEM SHALL 8E FULL OPERATIVE AND SUBJECT TO REGULATORY INSPECTION AND APPROVAL BY CONSTRUCTION <br /> EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS LOCATE AND AVOID CUTTING EXISTING ELECTRICAL TAPE MUST EXTEND TWO INCHES (THE TAPE WIDTH) PAST THE COLD SHRINK TUBE ONTO THE MANAGER. REV. DATE DESCRIPTION INITIALS <br /> REBAR WHEN DRILLING HOLES IN ELEVATED CONCRETE SLABS. UNDERLYING CABLE. TAPE SHALL BE WRAPPED 50 THAT NO VOIDS OR NR PACKETS ARE PRESENT. TAPE SHALL A 7/30/12 907,CD'S J.F, <br /> BE CUT WITH A SHARP KNIFE. 14. ALL WORK SHALL BE COORDINATED WITH 07HER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. <br /> 7, USE AND INSTALLATION OF CONCRETE EXPMSION/WEOGE ANCHOR. SHALL BE PER ICBO& C. BUM RUBBER TAPE INSTALLATION PROCEDURE: 0 09/12/12 100% CD'S RLS <br /> MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURES. 15. CONTRACTOR SHALL GUARANTEE MY/ALL MATERIALS AND WORK FREE FROM DEFECTS DR A PERIOD OF NOT LESS THAN ONE <br /> 1.REQUIRED MATERIAL:BLACK ELECTRICAL TAPE-2 INCH WIDE AND BUTYL RUBBER TAPE 2 TO 3 INCHES WIDE. YEAR FROM DATE OF ACCEPTANCE. <br /> 16. THE CORRECTION OF ANY DEFECTS SHALL BE CDMPLETEO WITHOUT MY ADDITIONAL CHARGE AND SHALL INCLUDE THE <br /> CONCRETE M 2.REQUIRED TOOLS: KNIFE OR SCISSORS. REPLACEMENT OF THE REPAIR OF MY OTHER PHASE OF THE INSTALLATION, WHICH MAY HAVE BEEN DAMAGED THEREIN. <br /> I. CONCRETE MASONRY UNITS SHALL BE MEDIUM WEIGHT UNITS CONFORMING TO ASTM CSO,GRADE STEP 1: THOROUGHLY CLEAN AND DRY THE SURFACE OF COAXIAL CABLE AND CONNECTOR TO REMOVE ALL 17, ADEQUATE AND REQUIRED LABILITY INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LOSS AND ANY/ALL <br /> N-1, (F'M=1,500 PS). MEDIUM WEIGHT(115 PCF). GREASE AND DIRT. WRAP CONNECTOR/GROUND KIT WITH TWO DYERS OF BUCK ELECTRICAL TAPE-2 INCH WIDTH PROPERTY DAMAGE FOR THE DURATION OF WORK. <br /> OVERLAPPING EACH ROW BY APPROXIMATELY 1/2 INCH. THESE LAYERS OF TAPE MUST BE WRAPPED TIGHT -- <br /> 2. MORTAR SHALL BE TYPE'S'(MINIMUM 1,800 FSI A7 28 DAYS). ENOUGH SO THAT NO VOIDS OR AIR PACKETS ARE PRESENT AND MUST EXTEND ONE INCH PAST THE 18. PROVIDE AND INSTALL CONDUIT, CONDUCTORS. PULL WIRES, BOXES, COVER PLATES AND DEVICES FOR ALL OUTLETS AS <br /> CONNECTOR/GROUND KIT ON EACH SIDE. TWO ROWS SHALL BE APPLIED, ONE IN EACH DIRECTION, WITH THE TOP INDICATED. <br /> 3. GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRNGTH OF 3,000 PSI AT 28 DAYS. ROW SHINGLED TO PROMOTE WATER RUNOFF. <br /> STEP 2: WRAP CONNECTOR/GROUND KIT WITH ONE LAYER OF BUM RUBBER TAPE (2 TO 3 INCHES WIDTH) OVER 19. DITCHING AND BACK FILL: CONTRACTOR SHALL PROVIDE FOR ALL UNDERGROUND INSTALLED CONDUIT AMD/OR CABLES INCLUDING <br /> 4. ALL CELLS CONTAINING REINFORCING STEEL OR EMBEDDED ITEMS AND ALL CELLS IN RETAINING THE BLACK ELECTRICAL TAPE OVERLAPPING EACH ROW BY APPROXIMATELY 1/2 INCH. THE BUM RUBBER TAPE EXCAVATION AND BACKFILLING AND COMPACTION. REFER TO NOTES AND REQUIREMENTS,EXCAVATION,AND BACKFILLING. <br /> WALLS AND WALLS BELOW GRADE SHALL BE SOLID GROUTED. MUST EXTEND 2 TO 3 INCHES (THE TAPE WIDTH) PAST THE ELECTRICAL TAPE AND COME IN GOOD CONTACT WITH 20. MATERIALS, PRODUCTS AND EQUIPMENT. INCLUDING ALL COMPONENTS THEREOF,SHALL BE NEW AND SHALL APPEAR ON THE <br /> S. ALL HORIZONTAL REINFORCEMENT SHALL BE PLACED IN BOND BEAM OR LINTEL BEAM UNITS. THE UNDERLYING CABLE. ON CONNECTORS,WHEN WEATHERPROOFING FROM THE MAIN LINE TO THE JUMPER,BUILD LIST OF U.L. APPROVED ITEMS AND SHALL MEET OR EXCEED THE REQUIREMENTS OF THE NEC,NEMA AND IEEE. <br /> UP THIS AREA WITH EXTRA BUM RUBBER TAPE TO INSURE A SMOOTH TRANSITION FREE OF VOIDS AND AIR <br /> 6. WHEN GROUTING IS STOPPED FOR ONE HOUR OR LONGER,HORIZONTAL CONSTRUCTION JOINTS PACKETS DOWN TO THE SMALLER DIAMETER CABLE. 21. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OR MANUFACTURES CATALOG INFORMATION OF ANY/ALL LIGHTING Fl%TURES, <br /> SHALL BE FORMED BY STOPPING THE GROUT POUR 1-1/2'BELOW TOP OF THE UPPERMOST STEP 3: WRAP CONNECTOR/GROUND KIT WITH TWO LAYERS OF BUCK ELECTRICAL TAPE 2 INCH WIDTH SWITCHES AND ALL OTHER ELECTRICAL ITEMS FOR APPROVAL BY THE CONSTRUCTION MANAGER PRIOR TO INSTALLATION. <br /> UNIT. OVERLAPPING EACH ROW BY W INCH. THESE LAST TWO DYERS MUST BE WRAPPED USING A SHINGLED EFFECT. <br /> THE TOP LAYER SHALL BE WRAPPED 50 THAT THE ENDS ARE IN THE UPWARD DIRECTION CREATING A SHINGLCD 22. ANY CUTTING OR PATCHING DEEMED NECESSARY FOR ELECTRICAL WORK IS THE ELECTRICAL CONTRACTORS RESPONSIBILITY AND <br /> 7. ALL BOND BEAM BLOCK SHALL BE'DEEP CUT"UNITS. EFFECT WITH THE TAPE SO WATER WILL BE REPELLED AND NOT ALLOWED TO COLLECT AND POOL. THESE TOP SHALL BE INCLUDED IN THE COST FOR WORK AND PERFORMED TO THE SATISFACTION OF THE'CONSTRUCTION MANAGER' UPON <br /> FINAL ACCEPTANCE. <br /> B. PROVIDE INSPECTION AND CLCAN-OUT HOLES AT BASE OF VERTICAL CELLS HAVING GROUT LIFTS LAYERS ELECTRICAL TME MUST EXTEND TWO INCHES (EHE TME WIDTH) PAST THE BUTYL RUBBER TAPE ONTO NOT FOR CONSTRUCTION UNLESS <br /> THE UNDERLYING CABLE. 23. THE ELECTRICAL CONTRACTOR SHALL LIBEL ALL PANELS WITH ONLY TYPEWRITTEN DIRECTORIES.ALL ELECTRICAL WIRING SHALL LABELED AS CONSTRUCTION SET <br /> IN EXCESS OF 4'-0'OF HEIGHT. ALL LAYERS OF TAPE SHALL BE WRAPPED SO THAT NO VOIDS OR AIR PACKETS ARE PRESENT. THE LAST WRAP BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. <br /> 9. ALL GROUT SHALL BE CONSOLIDATED WITH A MECHANICAL VIBRATOR. OF TAPE SHALL NOT BE PULLED OR STRETCHED.ALL TAPE SHALL BE CUT WITH A SHARP KNIFE OR SCISSORS, L.I�.1.\SLIR1: <br /> D. SELF-AMALGAMATING TAPE INSTALLATION PROCEDURE: 24. DISCONNECT SWITCHES SHALL BE H.P. RATED HEAVY-DUN, QUICK-MAKE AND QUICK-BREAK ENCLOSURES,AS REQUIRED BY <br /> 10. CEMENT SHALL BE AS SPECIFIED FOR CONCRETE. EXPOSURE TYPE. <br /> 11. REINFORCING BARS - SEE NOTES UNDER'STRUCTURAL CONCRETE NOTES" FOR REQUIREMENTS. 1. REQUIRED MATERIAL: SELF-AMALGAMATING TAPE -1.5 INCHES WIDE AND BLACK ELECTRICAL TAPE - 2 INCHES 25. ALL CONNECTIONS SHALL BE MADE WITH A PROTECTIVE COATING OF M ANTI-OXIDE COMPOUND SUCH AS "NO-OXIDE A"BY <br /> WIDE. DEMBORNE CHEMICAL CO. COAT ALL WIRE SURFACES BEFORE CONNECTING,EXPOSED COPPER SURFACES, INCLUDING GROUND <br /> 12. PROVIDE ONE BAR DIAMETER(A MINIMUM OF 1/21 GROUT BETWEEN MAIN REINFORCING AND BARS, SHALL BE TREATED - NO SUBSTITUTIONS. <br /> MASONRY UNITS. 2. REQUIRED TOOLS: KNIFE OR SCISSORS. <br /> 2fi. RFACEWAYS: CONDUIT SHALL BE SCHEDULE 40 PVC MEETING OR EXCEEDING NEMA TC2 - 1990. CONTRACTOR SHALL PLUQ AND <br /> 13. LOW LIFT CONSTRUCTION, MAXIMUM GROUT POUR HEIGHT IS 4 FEET. STEP 1: THOROUGHLY CLEAN AND DRY THE SURFACE OF COAXIAL CABLE AND CONNECTOR 10 REMOVE ALL CAP EACH END OF SPARE AND EMPTY CONDUITS AND PROVIDE TWO SEPARATE PULL STRINGS - 200 LBS TEST POLYETHYLENE <br /> GREASE AND DIRT. CORD. ALL CONDUIT BENDS SHALL BE A MINIMUM OF 2 FT. RADIUS. RGS CONDUITS WHEN SPECIFIED,SHALL MEET UL-6 FOR <br /> 14. HIGH LIFT GROUTED CONSTRUCTION MAY BE USED IN CONFORMANCE WITH PROJECT STEP 2• START WRAPPING SELF-AMALGAMATING TAPE ON THE CABLE AT LEAST 2 INCHES FROM THE GALVANIZED STEEL. ALL FITTINGS SHALL BE SUITABLE FOR USE WITH THREADED RIGID CONDUIT. COAT ALL THREADS WITH 'BR(TE <br /> SPECIFICATIONS AND SECTION 2104.6.1 OF U.B.C. ZINC' OR 'COLO CALV'. <br /> OONNECTOR/GROUND KIT. MAKE SURE TAPE IS STRETCHED TIGHT DURING THIS APPLICATION. <br /> 15. ALL CELLS IN CONCRETE BLOCKS SHALL BE FILLED SOLID WITH GROUT,EXCEPT AS NOTEED IN STEP 3: WHILE STRETCHING TAPE, MAKE ONE WRAP OF THE TAPE AROUND THE CABLE, MAKING SURE THE TAPE 27, SUPPORT OF ALL ELECTRICAL WORK SHALL BE AS REQUIRED BY NEC. <br /> THE DRAWINGS OR SPECIFICATIONS. IS WRAPPED ONTO ITSELF.THE TAPE WILL ONLY ADHERE TO ITSELF. 28. CONDUCTORS:CONTRACTOR SHALL USE 982 CONDUCTIVITY COPPER WITH TYPE THWN INSULATION, 600 VOLT,COLOR CODED. <br /> 16. CELLS SHALL BE IN VERTICAL ALIGNMENT, DOWELS IN FOOTINGS SHALL BE SCT TO AUGN WITH STEP 4. CONTINUE WRAPPING THE CABLE AND CONNECTOR/GROUND KIT USING HALF OVERLAP (0.75 INCH WIDE) USE SOLID CONDUCTORS FOR WIRE UP TO AND INCLUDING NO. 8 AWO. USE STRANDED CONDUCTORS FOR WIRE ABOVE 140. 8 <br /> CORCS CONTAINING REINFORCING STEEL. LAYERS. AWG, <br /> 17. REFER TO ARCHITECTURAL DRAWINGS FOR SURFACE AND HEIGHT OF UNITS,LAYING PATTER AND STEP 5: WRAP OVER AND PAST THE CONNECTOR/GROUND KIT AT LEAST 2 INCHES. 29. CONNECTORS FOR POWER CONDUCTORS: CONTRACTOR SHALL USE PRESSURE TYPE INSULATED TWIST-ON CONNECTORS FOR NO. <br /> JOINT TYPE. STEP 6: TO TERMINATE THE SELF-AMALGAMATING TAPE. WRAP THE TAPE AT LEAST ONE FULL ROUND OVER THE 10 AWG AND SMALLER, USE SOLDERLESS MECHANICAL TERMINAL LUGS FOR NO. B AWC AND LARGER. <br /> CABLE STRETCHING THE TAPE TIGHT. CUT THE TAPE USING KNIFE OR SCISSORS AND APPLY THE LOOSE END TO <br /> 18. SAND SHALL BE CLEAT,SHARP AND WELL GRADED. FREE FROM INJURIOUS AMOUNTS OF DUST, THE UNDERLYING SELF-AMALGAMATING TAPE USING THUMB PRESSURE, 70. SERVICE: 240/120V, SINGLE PHASE, 3 WIRE CONNECTIONS AVAILABLE FROM UTILITY COMPANY. OWNER OR OWNERS AGENT WILL <br /> LUMPS,SHALE,ALKALI OR ORGANIC MATERIAL. APPLY FOR POWER. MIFF(TF(IJ: <br /> STEP 7: TWO ROWS OF SELF-AMALGAMATING TAPE SHALL BE APPLIED IN THIS MANNER, IN ALTERNATING <br /> 19. BRICK SHALL CONFORM TO ASTM C-62 AND SHALL BE GRADE MW OR BETTER. DIRECTIONS. THE TOP LAYER SHALL BE WRAPPED SO THAT THE ENDS ARE IN AN UPWARD DIRECTION CREATING 31. TELEPHONE SERVICE: CONTRACTOR SHALL PROVIDE EMPTY CONDUITS WITH PULL STRINGS AS INDICATED ON DRAWINGS. / LL n L ��/�I _ <br /> A SHINGLED EFFECT WITH THE TAPE 50 WATER WILL BE REPELLED. V L �I L I\/1L NO 1 FES <br /> STEP 8: WRAP OVER SELF-AMALGAMATING TAPE WITH TWO LAYERS OF BLACK ELECTRICAL TAPE- 2 INCH WIDTH 32. ELECTRICAL AND TELCO RACEWAYS TO BE BURIED A MINIMUM OF 2' DEPTH. <br /> OVERLAPPING EACH ROW BY 1 INCH. THESE TOP TWO LAYERS MUST ALSO BE WRAPPED USING A SHINGLED 33. CONTRACTOR SHALL PLACE TWO LENGTHS OF WARNING TAPE AT A DEPTH OF 12' BELOW GROUND AND DIRECTLY ABOVE <br /> SHINGLED EFFECT WITH THE TME SO WATER WILL BE REPELLED AND NOT ALLOWED TO COLLECT AND POOL,EFFECT. THE DYERS SHALL BE WRAPPED SO THAT THE ENDS ARE IN THE UPWARD DIRECTION CRATING A ELECTRICAL AND TELCO SERVICE CONDUITS. CAUTIONS TAPE TO READ 'CAUTION BURIED ELECTRIC'OR 'BURIED TELECOM'. <br /> THESE TOP LAYERS OF ELECTRICAL TAPE MUST EXTEND TWO INCHES {THE TAPE WIDTH) PAST THE 34. ALL BOLTS SMALL BE STAINLESS STEEL. sIIFFTN11\1HTR- RF\im,N: <br /> SELF-AMALGAMATING TME ONTO THE UNDERLYING CABLE.ALL LAYERS OF TAPE SHALL BE WRAPPED SO THAT NO - <br /> VOIDS OR AIR PACKETS ARE PRESENT. THE LAST WRAP OF TAPE SHALL NOT BE PULLED OR STRETCHED. ALL GI <br /> TAPE SHALL BE CUT WITH A SHARP KNIFE OR SCISSORS. <br /> N-2 <br /> THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICFS IS STRICTLY PROHIBITED. <br />