Laserfiche WebLink
GENERAL NOTES AERIAL VIEW <br /> CODE AND STANDARDS , <br /> "ALL WORK SHALL COMPLY WITH 2017 NATIONAL ELECTRIC CODE(NEC),2015 INTERNATIONAL BUILDING CODE • ,I BLUE RAVEN <br /> (IBC),2015 INTERNATIONAL RESIDENTIAL CODE(IRC),2015 INTERNATIONAL PLUMBING CODE(IPC),AND ALL STATE E •' <br /> AND LOCAL BUILDING,ELECTRICAL,AND PLUMBING CODES. <br /> • • t • <br /> 2.DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. � • . �, •� 1403 N. Research Way <br /> SITE NOTES/OSHA REGULATION ` Orem, UT 84097 <br /> 1.A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. • �� • 800.377.4480 <br /> 2.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM. r,., �� 1 — WWW.BLUERAVENSOLAR.COM <br /> 3.THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS. <br /> 4.ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND r CONFIDENTIAL-THE INFORMATION <br /> THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT , HEREIN CONTAINED SHALL NOT BE <br /> THE BUILDING OR STRUCTURE. �� • - USED FOR THE BENEFIT OF ANYONE <br /> • 1i trt EXCEPT BLUE RAVEN SOLAR NOR <br /> R r SHALL IT BE DISCLOSED IN WHOLE OR <br /> SOLAR CONTRACTOR IN PART TO OTHERS OUTSIDE <br /> 1.MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. ' -� . p r RECIPIENTS ORGANIZATION,EXCEPT <br /> 2.IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER /� �.,+• + '�� • • IN CONNECTION WITH THE SALE AND <br /> THE MANUFACTURER'S INSTALLATION REQUIREMENTS. y:r WITHOUT THE WRITTEN PERMISSION/ f , r , USE OF THE RESPECTIVE EQUIPMENT, <br /> 3.AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF ,' I"�t OF BLUE RAVEN SOLAR LLC. <br /> STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. R t <br /> 4.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO j <br /> LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. . •, - t <br /> 5.CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A NAB C E P <br /> SUITABLE SEALING COMPOUND. • R �` • <br /> 6.DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. — /M CERTIFIED <br /> 7.ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE WIRING CLIPS. � T. �'� • • _ �� <br /> 8.MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT ! v • �• •1 PV INSTALLATION <br /> AVAI <br /> BLE. <br /> 9.ALLINVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AC r• `, •� PROFESSIONAL <br /> PHOTOVOLTAIC MODULES,DC COMBINERS,DC-TO-DC CONVERTERS,SOURCE CIRCUIT COMBINERS,AND •` r '� + Scott Gurney <br /> CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND ` #PV-011719-015866 <br /> LISTED FOR THE APPLICATION PER NEC 690.4(B). ^` <br /> 10.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. , �1 <br /> 11.TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN PROVIDED) �` CONTRACTOR: <br /> IN ACCORDANCE WITH NEC CODE 110.14(D)ON ALL ELECTRICAL CONNECTIONS. 'ky BRS FIELD OPS <br /> EQUIPMENT LOCATIONS + y 800-377-4480 <br /> 1.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT R�� • 1♦ t <br /> 1 <br /> WILL BE PROVIDED AS PER SECTION NEC 110.26. / <br /> 2.EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS <br /> SPECIFIED BY NEC 690.31(A)AND NEC TABLE 310.15(B). <br /> 3.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC • U <br /> APPLICABLE CODES. a ,. • f Q <br /> • Z <br /> 4.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. O <br /> M Y LO <br /> PROJECT INFORMATION: - � 00 M rn <br /> • C-0QuJ G� j M N Ln <br /> NUMBER OF STORIES: 2 i 0 O W W <br /> CONDUIT RUN: Interior _ ! �,a LL — N N <br /> ECOBEE QTY: 1 + v U) Cn <br /> LIGHT BULB QTY: 18 <br /> PV METER: Not Required DESIGN CRITERIA SITE SPECIFICATIONS SHEET INDEX J <br /> ROOF TYPE (1) INFORMATION: O N <br /> WIND SPEED: 110 mph CONSTRUCTION -V-B PV1 -COVER SHEET F_ — Cl) <br /> ROOF TYPE: Comp Shingle <br /> GROUND SNOW LOAD: 15 Ib/ftz ZONING: RESIDENTIAL PV2-SITE PLAN <br /> FRAMING TYPE: Manufactured Truss WIND EXPOSURE FACTOR: C PV3- ROOF PLAN � �` > U V <br /> SHEATHING TYPE: PLYWOOD SEISMIC DESIGN CATEGORY: D PV4-STRUCTURAL V 0-) W Q <br /> ATTACHMENT: SFM Infinity Switchblade Flashkit PV5- ELECTRICAL 3-LINE DIAGRAM <br /> RACKING: Unirac SFM Infinity @ 48" OC Portrait/72"OC Landscape DRAWING BY: <br /> NUMBER OF ATTACHMENTS: 32 SCOPE OF WORK PV6- ELECTRICAL CALCULATIONS <br /> PV7-WARNING LABELS AND LOCATIONS PremiumCAD <br /> ROOF TYPE (2) INFORMATION (IFAPPLICABLE): INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM AND ANY (ALL OTHER SHEETS AS REQUIRED) <br /> *SEE PV4.2 <br /> NECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION. SS- PRODUCT SPEC. SHEETS PLOT DATE: <br /> December 19, 2022 <br /> PROJECT NUMBER: <br /> SYSTEM TO BE INSTALLED INFORMATION: UTILITY COMPANY: 675781 <br /> DC SYSTEM SIZE: 5.925 kW DC Snohomish County Public Utilities District <br /> AC SYSTEM SIZE: 4.35 kW AC (PUD) SHEET NAME: <br /> MODULE TYPE: (15)QCells Q.PEAK DUO BLK ML-G10+ 395 COVER SHEET <br /> INVERTER TYPE: IQ8PLUS-72-2-US <br /> MONITORING: Enphase IQ Combiner 4 X-IQ-AM1-240-4 PERMIT ISSUER: REVISION: PAGE NUMBER: <br /> City of Everett 0 PV 1 <br />