My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1502 100TH ST SW 2023-12-11
>
Address Records
>
100TH ST SW
>
1502
>
1502 100TH ST SW 2023-12-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/11/2023 10:39:20 AM
Creation date
9/22/2023 11:25:15 AM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SW
Street Number
1502
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> Permit Number: P2303-003 Description:AFH-REPL DISHWASHER,SINK,TOILET <br /> Applied:3/3/2023 Approved: 3/3/2023 Site Address: 1502 100TH ST SW <br /> Issued:3/6/2023 Finaled:8/8/2023 City,State Zip Code: EVERETT,WA 98204-2614 <br /> Status: FINALED Applicant: BELETE HIRRA <br /> Parent Permit: B2201-059 Owner: HIRRA BELETE BEZA&BIWETA SIMEGN M <br /> Parent Project: Contractor: OWNER <br /> Details: <br /> SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS <br /> 3/8/2023 3/8/2023 PLUMB 03-ROUGH JEFF M RHODE CORRECTION see notes <br /> IN REQUIRED <br /> Notes: <br /> 206-571-9533 <br /> belete.hirra@yahoo.com <br /> -Provide access to under floor plumbing <br /> 3/9/2023 3/9/2023 PLUMB 03-ROUGH JEFF M RHODE CORRECTION see notes <br /> IN REQUIRED <br /> Notes: <br /> 206-571-9533 <br /> EELETE.HIRRA@YAHOO.COM <br /> -water lines under floor need support <br /> Suspended piping shall be supported at intervals not to exceed those shown in Table 313.3. <br /> -illegal non drainage fittings used under flood rim level for toilet room group <br /> Vents less than 6 inches(152 mm)above the flood-level rim of the fixture shall be installed with approved drainage fittings,material,and grade to the <br /> drain. <br /> -incorrect wet vent application washer box draining into vertical wet vent <br /> 908.1 Vertical Wet Venting <br /> Wet venting is limited to vertical drainage piping receiving the discharge from the trap arm of one and two fixture unit fixtures that also serves as a vent <br /> not exceeding four fixtures.Wet-vented fixtures shall be within the same story;provided,further,that fixtures with a continuous vent discharging into a <br /> wet vent shall be within the same story as the wet-vented fixtures.No wet vent shall exceed 6 feet(1829 mm)in developed length. <br /> -vent for toilet use of improper fittings 903.3 <br /> -vent for toilet taken off below drainage flow line <br /> 905.2 Horizontal Drainage Pipe <br /> Where vents connect to a horizontal drainage pipe,each vent pipe shall have its invert taken off above the drainage centerline of such pipe <br /> downstream of the trap being served. <br /> 3/14/2023 3/14/2023 PLUMB 03-ROUGH JEFF M RHODE CORRECTION see notes <br /> IN REQUIRED <br /> Notes: <br /> 206-571-9533 <br /> EELETE.HIRRA@YAHOO.COM <br /> -incorrect drainage fittings used below flood rim <br /> I <br /> Printed: Friday, 25 August,2023 1 of 2 rk <br /> SUPERION <br />
The URL can be used to link to this page
Your browser does not support the video tag.