Laserfiche WebLink
r <br /> Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code(WSEC)and ACCA Manuals <br /> J and S.This tool will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br /> Please complete the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some <br /> values will be calculated for you. If you do not see the selection you need in the drop-down options, please contact the WSU Energy Program at <br /> energycode@energy.wsu.edu or(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> SE 151ST ST PAUL C RECTOR 253 332 6244 <br /> PAULCo1RECTO RDESIG NS.COM <br /> Heating System Type: OM other systems (D Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions" <br /> Design Temperatw e <br /> Instructions Design Temperature Difference(AT) 47 <br /> LEverett JC v AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 704 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.0 5,632 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> u-030 I. J 0.300 16 4.80 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 --- <br /> Insulation <br /> AtticU-Factor X Area = UA <br /> Instructions 1 R 49 .j 0.026 75 1.95 <br /> nal% iA <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X _ Area UA <br /> Instructions --- --- - _--- '— <br /> Select R-Value Li No selection --- cc,S. <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA © - <br /> CNI <br /> W <br /> Instructions 0) <br /> j I R-21 Intermediate _ 0.056 840 47.04 <br /> W .-- W <br /> Floors U-Factor X Area UA © Z 11-1.+ <br /> Instructions O <br /> 1 I Select R-Value No selection --- 11 a I1 '� �„ `„ <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA =_i�` ~„a) <br /> Instructions 1 0.028 <br /> L"�j r U <br /> No Below Grade Walls in this project. y J <br /> Slab Below Grade(see Figure 1) F-Factor X Length UA <br /> Instructions — No selection 704 <br /> I rSelect conditioning <br /> Slab on Grade(see Figure 1) F-Factor X Length UA <br /> Instructions j No selection <br /> i rSelect R-Value <br /> Location of Ducts <br /> Instructions I Duct Leakage Coefficient <br /> Conditioned Space v <br /> 1.00 <br /> Sum of UA 53.79 <br /> Envelope Heat Load 2,528 Btu/Hour <br /> Figure 1. Sum of UA x 4T <br /> 111111b111... <br /> Air Leakage Heat Load 2,859 Btu/Hour <br /> Volume x 0.6 x 41-x 0.018 <br /> Above Grade Building Design Heat Load 5,387 Btu I Hour <br /> Air leakage+envelope heat loss <br /> Building and Duct Heat Load 5,387 Btu/Hour <br /> Ducts in unconditioned space:sum of building heat loss x 1.10 <br /> Ducts in conditioned space:sum of building heat loss x 1 <br /> Maximum Heat Equipment Output 6,734 Btu/Hour <br /> Building and duct heat loss x 1.40 for forced air furnace <br /> Building and duct heat loss x 1.25 for heat pump <br /> I I 1I. (07/01/13) <br />