Laserfiche WebLink
I 2 <br /> 3 4 5 <br /> in THESE DOCUMENTS HAVE NOT BEEN EvERETT Hwy 526 G P D GROUP <br /> APPROVED FOR THE ISSUANCE OF Professional Corporation <br /> ilimmu, PUBLIC WORKS. MECHANICAL, 5=°5°° Main Street, 2531 <br /> CAL, FIRE Akron,OH 44311 <br /> 330,572 2100 Fax 330 572.7101 <br /> rnim,„ a t PLUMBIUPPRENG <br /> PEIO ELECTRICAL OR 2022 5G N R RADIO <br /> PLUMBfNG PERMITS. <br /> FA#: 10102251 / SITE ID : SN91 - at&t <br /> CITY Or E FRPTT Mobility <br /> 209 EAST CASINO ROAD 19801 SW 72ND AVENUE,STE 2°0 <br /> ,cv.: cz.:,,,, u UAunnN,OR 97esz <br /> +'I"� VIE � Fi PERNPITM O b I I t1E / EVERETT, WA 98208 <br /> SNOHOMISH COUNTY <br /> JUL 1 2022 -+ FROM SEATTLE-TACOMA INTERNATIONAL AIRPORT:DEPART AIRPORT ON AIRPORT EXPRESSWAY(0.8 MI). KEEP RIGHT FOR EXIT TO WA-518 E/I-5/1-405/SEATTLE/TACOMA AND MERGE ONTO WA-518E I a sTe c <br /> ,; (0.6 MI).MERGE ONTO WA-518 E(0.8 MI).USE THE LEFT LANE TO MERGE ONTO 1-5 N TOWARD SEATTLE(3.2 MI).KEEP LEFT TO STAY ON I-5 N (7.9 MI).KEEP RIGHT TO STAY ON 1-5 N (5.0 MI).KEEP LEFT Network Solutions <br /> TO STAY ON 1-5 N (16.4 MI).TAKE EXIT 189 TO MERGE ONTO WA-526 W TOWARD MUKILTEO(2.0 MI).TAKE THE EVERGREEN WAY EXIT(0.2 MI).USE THE RIGHT LANE TO TURN LEFT ONTO EVERGREEN <br /> T WAY(0.1 MI).TURN RIGHT ONTO E CASINO ROAD(266 FT).TURN RIGHT INTO FIRST DRIVEWAY INTO STRIP WALL AND MAKE A RIGHT(79 FT).DESTINATION WILL BE ON THE LEFT(52 FT). 22263 68TH AVENUE SOUTH <br /> �°r <br /> P C+'TPi TT A <br /> Thad:9'- " ROOFTOP KENT,WA 98032 <br /> I 'F <br /> I <br /> AT&T SITE NAME: EVERETT HWY 526 AT&T MOBILITY PROPOSES CHANGES TO THE EXISTING UNMANNED 1 ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE I h <br /> AT&T FA NUMBER: 10102251 TELECOMMUNICATIONS FACILITY WITH THE GENERAL SCOPE OF WORK CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING SHEET NUMBER DESCRIPTION 3 <br /> AT&T SITE ID: SN91 DESCRIBED BELOW: AUTHORITIES.NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT <br /> CONFORMING TO THESE CODES. O 3 , <br /> RFDS NAME/REVISION: STTLWASN91/1.00/11/09/2021 TOWER SCOPE OF WORK: T-1 TITLE SHEET a S <br /> ADDRESS: 209 EAST CASINO ROAD •REMOVE(6)KATHREIN 80010865 ANTENNAs BUILDING CODE 2018 WASHINGTON STATE BUILDING CODE(2018 IBC) N-1 GENERAL NOTES Ez 2 <br /> EVERETT,WA 98208 •REMOVE(3)KATHREIN 742-264 ANTENNAs MECHANICAL CODE 2018 WASHINGTON STATE MECHANICAL CODE(2018 IMC) o ; <br /> COUNTY: SNOHOMISH •REMOVE(1)RAYCAP FC12-PC6-10E OVP ELECTRICAL CODE 2020 NATIONAL ELECTRICAL CODE(2020 NFPA 70) N-2 ELECTRICAL NOTES 0 6 2 <br /> •REMOVE(3)RAYCAP DC2-48-60-0-9E OVPs FIRE CODE 2018 WASHINGTON STATE FIRE CODE(2018 IFC) C-1 OVERALL SITE PLAN o 3 JURISDICTION: CITY OF EVERETT •INSTALL(3)NOKIA AEQK ANTENNAs D <br /> C-2 COMPOUND PLAN S z <br /> TAXLOT NUMBER: 00598700000101 <br /> •INSTALL(3)CELLMAX CMA-UBTMLBMLBHH-6516-16-21-21 ANTENNAS _ II <br /> ZONING DESIGNATION: E-1MOU •INSTALL(3)RAYCAP-DC6-48-60-18 OVPs C-3 EXISTING&PROPOSED EQUIPMENT PLANS - - <br /> �, OCCUPANCY CLASSIFICATION: U •INSTALL(6)3/4"DC POWER CABLES(2 PER SECTOR) <br /> C-4 EXISTING&PROPOSED TOWER ELEVATIONS ¢ - <br /> - <br /> TYPE OF CONSTRUCTION: II-B •INSTALL(3)3/8"FIBER CABLE(1 PER SECTOR) ❑ 8 8 <br /> •EXISTING COAX MAY HAVE TO BE REMOVED TO ALLOW FOR NEW C-5 EXISTING&PROPOSED ANTENNA PLANS <br /> A.D.A.COMPLIANCE: FACILITY IS UNMANNED AND DC TRUNKS AND NEW FIBER TRUNKS ACCESSIBILITY REQUIREMENTS: < o <br /> rt <br /> NOT FOR HUMAN HABITATION FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION.HANDICAPPED ACCESS C-6 EXISTING&PROPOSED EQUIPMENT SCHEDULES <br /> TOWER OWNER: JANG BANG JA GROUND SCOPE OF WORK: REQUIREMENTS •ARE NOT REQUIRED IN ACCORDANCE WITH THE 2018 IBC BUILDING CODE. C-7 EQUIPMENT SPECIFICATIONS 0V14ER <br /> B 8380 SE 43RD ST •REMOVE(6) DIPLEXERs APPLICABLE CODES C-8 EQUIPMENT SPECIFICATIONS i�"F N`*rz'����.� <br /> MERCER ISLAND,WA 98040 •RELOCATE(3)NOKIA 4T4R B5 160W AHCA RRHs TO ROOFTOP I - • C� <br /> •INSTALL(2)ABIO&(1)ASIL IN EXISTING 5G SUBRACK C2 G-1 GROUNDING SCHEMATIC ` .r e <br /> LATITUDE/LONGITUDE: N 47.9225000° APPLICANT ZONING MANAGER / ?q� <br /> (NAD83) W-122.2292500° AT&T MOBILITY TBD G-2 GROUNDING DETAILS ./a11. <br /> GROUND ELEVATION: ±574'(GOGGLE EARTH)AMSL 19801 SW 72 AVENUE,SUITE 200 PHONE: XXX-XXX-XXXX RF-1 RF PLUMBING DIAGRAM •1� 'Ph 889 <br /> TUALATIN,OR 97062 COMPANY:MASTEC NETWORK SOLUTIONS •s3• - <br /> ADDRESS: 22263 68TH AVENUE SOUTH RF-2 RF PLUMBING DIAGRAM �r,,vnti.It'", <br /> PROJECT MANAGER KENT,WA 98032 RF-3 RF PLUMBING DIAGRAM '."°"IT1 n ,20231 <br /> PACE#1: MRWOR053173 PTN#1: 3801AOYFH3 ROBERT LEIGHTON 5 <br /> PACE#2: MRWOR052624 PTN#2: 3801AOYFRP PHONE 206-817-0733 ENGINEER 06/06/2022 <br /> PACE#3: MRWOR050747 PTN#3: 3898A0WR5Z <br /> COMPANY:MASTEC NETWORK SOLUTIONS GPD GROUPto <br /> ATTACHMENT <br /> ADDRESS: 22263 68TH AVENUE SOUTH PROFESSIONAL CORPORATION <br /> PACE#4: MRWOR050734 PTN#4: 3898AOWT5E MOUNT MODIFICATION DESIGN cNi <br /> PACE#5: MRWOR050721 PTN#5: 3898A0WT59 NOTE: KENT,WA 98032 520 SOUTH MAIN STREET,SUITE 2531 Q <br /> AKRON,OH 44311 co W <br /> = PACE#6: MRWOR050721 PTN#6: 3898AOWT59 THE POWER DESIGN FOR ANY AC ELECTRICAL POWER CANGES IS TO CONSTRUCTION MANAGER O o <br /> CONTACT:CHAD BURTON,330-572-2100 N W <br /> BE PERFORMED BY OTHERS AND IS SHOWN HERE FOR REFERENCE TBD O <br /> PURPOSES ONLY.AT&T IS SOLELY RESPONSIBLE FOR THE PHONE: XXX-XXX-XXXX z< I <br /> ELECTRICAL POWER DESIGN. i <br /> PROJECT SUMMARY PROJECT DESCRIPTION PROJECT TEAM I- W F.', SHEET INDEX W <br /> Li; ' Mint <br /> 1YEHLY > ?' •�-t B 9; W a W <br /> ... 4� . I lj ... "r9 <br /> Ei <br /> r_ 7K- - STRUCTURAL ANALYSIS BY: KIMLEY-HORN AND ASSOCIATES,INC W 2 w I— <br /> Permit#: B2206-025 '= `'r. K-H PROJECT#:KHCLE-22734 N <br /> DATED:04/05I2022 W <br /> w Site Address: 209 E CASINO RD _ , , PASSING. <br /> <' Owner: B11 INVESTMENTS LLC -- <br /> o I t Wi ° MOUNT ANALYSIS BY: KIMLEY-HORN AND ASSOCIATES,INC <br /> O Tenant: AT&T MOBILITY =' --,...____' K-H PROJECT#:KHCLE-24632 ISSUED FOR: <br /> § = FA- <br /> ' = DATED:05/23/2022 <br /> x Appr. .Date: 6/10/2022 �" • �r... REVIEW os3azl <br /> 1;: ..., :..„ .. . PASSING WITH MODIFICATIONS. <br /> g Proposed Use: COMMERCIAL ALTERATIONS PERMIT <br /> ' 11 i.. CONSTRUCTION <br /> i 3 Description: ANTENNA MODIFICATION REMOVE(3) I .- 4,r I \', a:-, I-,^-^ ,at = ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 22"x34". <br /> 8 ANTENNAS(4)SURGE SU PRSRS a f, SFE i b' : CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSION AND RECORD - <br /> c ° J . CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE <br /> !! `tom 14 ;• .., p ` <br /> o \ -� ' ;` / Ft J . ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING PROJECT IMAGER DESIGNER <br /> H g, %,°' , I. WITH THE WORK OR BE RESPONSIBLE FOR SAME. <br /> 1 <br /> x. t CB CT <br /> Fo Reviewed By: Date:%O �?.'t` _r REFERENCE DOCUMENTS <br /> F,wx Office Set Job Site Set Fire/Pla ning Set t I - t • 1,• ft • 4 ' _ - \ <br /> GPD JOB NO. <br /> o �"�� k t o, c �_ �' w� OH 2021723.06.45587.01 <br /> §a ■ ll: l a .. *w* r I x +� �(AT.T.WASHTNGTON ONE G4IJ, <br /> N "a., . s� r� (800)4245555 $/' <br /> z o A +'- � t A..— <br /> x3 (�r)/ CALL 3 WORKING DAYS y <br /> ll. — A 44 .t '. A ,a% '" 1 _:.�.+. IL" :2^4 ^, BEFORE YOU DIGI <br /> oN, I VICINITY MAP AERIAL T.1 <br />