GENERAL: <br />1. ALL MATERIALS AND WORK SHALL CONFORM TO THE REQUIREMENTS OF THE APPLICABLE INTERNATIONAL <br />BUILDING CODE (IBC). <br />2. CONSTRUCTION METHODS AND PROJECT SAFETY: DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED <br />STRUCTURE AND DO NOT INDICATE METHODS, PROCEDURES, OR SEQUENCE OF CONSTRUCTION. TAKE <br />NECESSARY PRECAUTIONS TO MAINTAIN AND ENSURE THE INTEGRITY OF THE STRUCTURE DURING <br />CONSTRUCTION. THE FOR WILL NOT ENFORCE SAFETY MEASURES OR REGULATIONS. THE CONTRACTOR <br />SHALL DESIGN, CONSTRUCT, AND MAINTAIN ALL SAFETY DEVICES AND SHALL BE SOLELY RESPONSIBLE FOR <br />CONFORMING TO ALL LOCAL, STATE, AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS, AND <br />REGULATIONS. <br />3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS PRIOR TO THE START <br />OF CONSTRUCTION AND NOTIFY THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES OR INCONSISTENCIES <br />THAT ARE FOUND. NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE <br />DRAWINGS. <br />4. ALL OMISSIONS AND/OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND <br />SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND FIELD INSPECTOR. THE <br />ENGINEER SHALL PROVIDE A SOLUTION PRIOR TO PROCEEDING WITH ANY WORK AFFECTED BY THE <br />CONFLICT OR OMISSION. <br />5. WHERE NO CONSTRUCTION DETAILS ARE SHOWN OR NOTED FOR ANY PART OF THE WORK, CONSTRUCT IN <br />ACCORDANCE WITH THE STEEL CONSTRUCTION MANUAL, 14TH EDITION OR 2010 ALUMINUM DESIGN <br />MANUAL. <br />6. WHEN A DETAIL IS IDENTIFIED AS TYPICAL, THE CONTRACTOR IS TO APPLY THIS DETAIL IN ESTIMATING <br />AND CONSTRUCTION TO EVERY LIKE CONDITION WHETHER OR NOT THE REFERENCE IS REPEATED IN EVERY <br />INSTANCE. <br />7. ANY CHANGE TO THE DESIGN AS SHOWN ON THE DRAWINGS REQUIRES PRIOR WRITTEN APPROVAL FROM <br />DESIGN ENGINEER OF RECORD BEFORE CONSTRUCTION. <br />8. WORK PERFORMED IN CONFLICT WITH THE STRUCTURAL DRAWINGS OR APPLICABLE BUILDING CODE <br />REQUIREMENTS SHALL BE CORRECTED AT THE EXPENSE OF THE CONTRACTOR. <br />9. VERIFICATION: VERIFY ALL DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS BEFORE STARTING WORK. <br />NOTIFY THE FOR IMMEDIATELY OF ANY DISCREPANCIES. <br />EXISTING CONDITIONS: <br />1. IF EXISTING CONDITIONS ARE NOT AS DETAILED IN THIS DESIGN, THE INSTALLER SHALL CEASE WORK <br />AND NOTIFY MURDOCH ENGINEERING IMMEDIATELY. <br />2. MURDOCH ENGINEERING WILL NOT BE PERFORMING ON -SITE INSPECTIONS OR VERIFICATIONS. IT IS THE <br />RESPONSIBILITY OF THE INSTALLER, STRUCTURE OWNER, AND PROPERTY OWNER TO IDENTIFY EXISTING <br />CONDITIONS AND CONTACT MURDOCH ENGINEERING WITH ANY DISCREPANCIES OR CONCERNS. <br />3. INSTALLER SHALL CONFIRM THE DIAMETER AND THICKNESS OF EXISTING MEMBERS AND NOTIFY <br />MURDOCH ENGINEERING OF ANY DISCREPANCIES. <br />4. INSTALLER SHALL INSPECT AND CONFIRM THE QUALITY OF EXISTING STRUCTURE AS "IN GOOD REPAIR". IF <br />THERE ARE ANY INDICATIONS THATTHIS IS NOT THE CASE, INSTALLER SHALL CEASE WORK IMMEDIATELY <br />AND NOTIFY MURDOCH ENGINEERING. <br />5. ANY EXISTING INFORMATION SHOWN HAS BEEN FURNISHED BY THE PERSON(S) OR COMPANY THIS <br />DOCUMENT WAS PREPARED FOR <br />(SEE TITLE BLOCK). MURDOCH ENGINEERING IN NO WAY CERTIFIES THIS INFORMATION AS "AS -BUILT". <br />IF THERE IS ANY REASON TO BELIEVE THE EXISTING CONDITIONS DETAILED HEREIN ARE NOT ACCURATE, <br />MURDOCH ENGINEERING SHALL BE NOTIFIED IMMEDIATELY. <br />STEEL <br />1. STEEL SHAPES SHALL CONFORM TO THE FOLLOWING: <br />ROUND HSS <br />ASTM A500, GR B <br />Fy=42 KSI <br />MIN. <br />SQUARE/RECT HSS <br />ASTM A500, GR B <br />Fy=46 KSI <br />MIN. <br />THREADED ROD <br />F1554 GR 55 <br />Fy=55 KSI <br />MIN. <br />STEEL PLATE STD. <br />ASTM A36 ASTM <br />Fy=36 KSI <br />MIN. <br />PIPE <br />A53, GR B <br />Fy=35 KSI <br />MIN. <br />2. BOLTS SHALL CONFORM TO ASTM A325 UNO. <br />3. BOLTS AND THREADED ROD SHALL BE HOT -DIP GALVANIZED PER ASTM F2329 UNO. <br />4. ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 UNO. <br />5. NUTS SHALL CONFORM TO ASTM A563. <br />6. WASHERS SHALL CONFORM TO ASTM F844. <br />7. STEEL HARDWARE SHALL BE HOT -DIP GALVANIZED PER ASTM A153 LINO <br />8. WELDING: <br />a. WELD STRUCTURAL STEEL IN COMPLIANCE WITH ANSI/AWS D1.1 AND AISC SPECIFICATION, CHAPTER <br />J. WELDERS SHALL BE CERTIFIED AS REQUIRED BY GOVERNING CODE AUTHORITY. WELDING SHALL <br />BE DONE BY ELECTRIC ARC PROCESS USING LOW -HYDROGEN ELECTRODES WITH SPECIFIED TENSILE <br />STRENGTH NOT LESS THAN 70 KSI UNLESS NOTED OTHERWISE. <br />b. ALL SHOP AND FIELD WELDS SHALL BE PERFORMED BY AN AWS OR ICC CERTIFIED WELDER WITH <br />ACTIVE STATUS AT TIME OF WELDING <br />c. UNLESS A LARGER WELD SIZE IS INDICATED, PROVIDE MINIMUM SIZE WELDS PER <br />AISC SPECIFICATION, SECTION J2, TABLE J2.4 <br />d. BASE PLATES SHALL BE WELDED ON TOP AND BOTTOM WITH CONTINUOUS WELDS <br />OF AT LEAST 1/4" (IF PLATE IS CUT TO FIT TUBE INTO PLATE) <br />The designs, details and specifications contained in this drawing are confidential. The recipients of this drawing hereby acknowledge and agree that it is the sole <br />property of Murdoch Engineering and that they shall neither use nor reveal any of the designs, details and specifications contained in this drawing, outside of <br />the contractual agreement expressed written permission from Murdoch Engineering. <br />Deviations from this drawing shall not be made without consulting Murdoch Engineering. In case of incongruities between drawings, specifications, and details <br />included in contract documents, Murdoch Engineering shall decide which indication must be followed and their decision shall be final. <br />Copyright Murdoch Engineering. <br />All rights reserved. <br />ALUMINUM: <br />1. FABRICATE AND ERECT ALUMINUM IN COMPLIANCE WITH THE ALUMINUM ASSOCIATION (AA) 2010 <br />ALUMINUM DESIGN MANUAL (ADM) 1, THE SPECIFICATIONS FOR ALUMINUM SHEET METAL WORK <br />(ASM35), AND IBC CHAPTER 20. <br />2. PIPE AND TUBE SHALL BE 6061-T6 PER ASTM B241 OR B429 WITH Ftu=38 KSI MIN, Fty=35 KSI MIN, Ftuw=24 <br />KSI MIN, Ftyw=15 KSI MIN. <br />3. STD STRUCTURAL PROFILES SHALL BE 6061-T6 PER B308 WITH Ftu=38 KSI MIN, Fty=35 KSI MIN, Ftuw=24 <br />KSI MIN, Ftyw=15 KSI MIN. <br />4. SHEET AND PLATE SHALL BE 6061-T6 PER ASTM B209 WITH <br />Ftu=42 KSI MIN, Fty=35 KSI MIN, Ftuw=24 KSI MIN, Ftyw=15 KSI MIN. <br />5. EXTRUSIONS SHALL BE 6061-T6 PER ASTM B241 OR B429 WITH Ftu=38 KSI MIN, Fty=35 KSI MIN, Ftuw=24 KSI <br />MIN, Ftyw=15 KSI MIN. <br />6, ALL SHOP AND FIELD WELDS SHALL BE PERFORMED BY AN AWS OR ICC CERTIFIED WELDER WITH <br />CURRENT STATUS AT TIME OF WELDING <br />7 UNLESS A LARGER WELD SIZE IS INDICATED, PROVIDE MINIMUM SIZE WELD PER ADM. ALL ALUMINUM <br />WELDED JOINTS SHALL HAVE WELD SIZES OF AT LEAST 14 INCH <br />8. FILLET WELDS SHALL NOT EXCEED THINNEST MEMBER WALL THICKNESS JOINED. <br />9. ALUMINUM WELD FILLER SHALL BE 5356 ALLOY <br />10. WELDING PROCESS GMAW OR GTAW SHALL BE IN ACCORDANCE WITH AWS D1.2 - <br />11.ALUMINUM CHANNEL LETTERS SHALL BE CONSTRUCTED OF 0.090" RETURNS AND 0.125" BACKS <br />MINIMUM, UNLESS A LARGER SIZE IS INDICATED ON DRAWINGS. THIS NOTE SHALL SUPERCEDE DRAWING <br />DETAILS. <br />12.PROVIDE NEOPRENE GASKET BETWEEN DISSIMILAR METALS TO PREVENT GALVANIC CORROSION <br />13.ALUMINUM DIRECTLY EMBEDDED INTO CONCRETE SHALL BE CAPPED AT BOTTOM AND COATED WITH <br />BITUMINOUS COATING OR POLYURETHANE WHERE IN CONTACT WITH CONCRETE. <br />14.FASTENERS BETWEEN DISSIMILAR METALS SHALL BE STAINLESS STEEL 316. <br />SCOPE OF WORK: <br />1. LIMITS OF LIABILITY TO EXTEND ONLY TO THE QUANTITY INDICATED. ATTEMPTS IN PART <br />OR IN WHOLE TO INSTALL GREATER QUANTITIES THAN THOSE SPECIFIED WITHOUT <br />CONSULTING MURDOCH ENGINEERING SHALL VOID ALL PROFESSIONAL LIABILITY AND <br />COVERAGE. <br />DESIGN SPECIFICATIONS <br />IBC 2018 with WA amendments <br />ASCE 7-16 <br />ACI 318-14 e.n a .xw.,•m•,�msm,a.�i w�<,... <br />ANSI/AISC 360-16 <br />DESIGN LOADS <br />Wind V= 98 mph <br />Exposure C <br />Risk Cat. I I <br />Grnd. Snow Pg= 15 psf <br />MURDOClinj <br />ENGINEERIN <br />SIGN STRUCTURE PROFESSIONALS <br />murdochengineering.com <br />(973) 570-8215 <br />2399 NJ-34 A-2 <br />Manasquan, NJ 08736 <br />PREPARED FOR: <br />Stratus <br />ri <br />0 <br />N <br />00 <br />rn <br />u <br />< <br />f0 <br />� <br />L <br />0J <br />v <br />LU <br />L <br />41 <br />W <br />N <br />4J <br />L <br />f73 <br />Q <br />ILLW <br />VI <br />d <br />� � <br />F <br />a`6 <br />� <br />u o <br />0 <br />a <br />a <br />i5 00 <br />� N <br />a <br />�5�, MURDO <br />11 <br />04 PIASI A <br />52939 9 w� <br />�GISTER� <br />�S%NAL���� <br />MURDOC <br />ENG INEERIN <br />SIGN STRUCTURE PROFESSIONALS <br />2399 A-2 NJ-34 <br />MANASQUAN,NJ01173 <br />(973) 570 215 x0 <br />j 7/5/2023 <br />Jere rdoch, PE <br />Prof ss 'al Engineer <br />WA Lic. #52939 <br />DWG TITLE: <br />GENERAL NOTES <br />SHEET: <br />SIZE: <br />S.1 <br />B <br />