My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2815 BAKER AVE 2023-12-06
>
Address Records
>
BAKER AVE
>
2815
>
2815 BAKER AVE 2023-12-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 9:11:30 AM
Creation date
10/2/2023 10:06:46 AM
Metadata
Fields
Template:
Address Document
Street Name
BAKER AVE
Street Number
2815
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c Mt <br /> ; <br /> D <br /> b FEB i= FEB 2 8 2023 <br /> info@b2engineers.com <br /> a5-3180031(C e t sit' waseqsa - ) CITY <br /> Services <br /> 02 <br /> BAKER BUILDING <br /> 2815 BAKER AVE, EVERETT, WA 98201 <br /> RESPONSE TO COMMENTS .p� °'�RALti�G`��,� <br /> PROJECT NO: 22290 DATE:02/23/23 SS'ONAL ENG <br /> PREPARED BY: BASRI BASRI PE,SE <br /> 1. The project proposed demolishing a portion of the existing concrete wall to modifying the door <br /> opening. See IEBC Section 806.2, and IBC Sections 1603.1, 1604.1, 1604.2, 1604.4, 1901.2, and <br /> 1901.5. The following comments should be addressed: <br /> a. A structural partial plan for the area around the modified opening should be provided indicat- <br /> ing the structure above bearing on the length of wall to be modified (e.g., beams, girders, <br /> columns, posts, walls, pilasters, etc.). <br /> RESPONSE TO COMMENT a: SEE REVISED 5 OF S-1 SHOWING EXISTING FLOOR FRAMING <br /> AT MAIN FLOOR(THE SAME FRAMING LAYOUT AT 2ND FLOOR AND ROOF). THE HEIGHT OF <br /> EXISTING MASONRY WALL ABOVE THE CONCRETE HEADER IS INDICATED ON THE PLAN AS <br /> WELL <br /> b. Section 3/S-1 should be revised to specify the dimensions for the remaining wall section. <br /> c. Section 3/S-1 should be revised to indicate the remaining reinforcement. The wall should be <br /> scanned to accurately determine the sizes, numbers, and locations of rebar in the wall. See <br /> ACI 318-14 Section 27.3.1.2. <br /> d. Documentation substantiating the condition and strength of the existing concrete should be <br /> submitted for review. See ACI 318-14 Section 27.3.1.3. <br /> e. Calculations should be submitted substantiating the flexural and shear capacity of the wall. <br /> Note that the wall supports the existing URM wall above that provides a bearing load path for <br /> both the upper floors and the roof. <br /> f. As an alternative to Items (b) through (e), a new supplemental gravity frame with founda- <br /> tions should be installed to support the existing structure. Calculations substantiating the de- <br /> sign of the frame and foundations should be submitted for review. <br /> RESPONSE TO COMMENT f. : DOUBLE STEEL CHANNEL C8X11.5 HAS BEEN USED TO CARRY <br /> THE EXISTING WEIGHT OF THE HEADER, MASONRY WALL AND FLOOR FRAMING. PLEASE <br /> SEE ATTACHED CALCULATIONS PAGE 1 AND 2.THE LOADS ARE TRANSFERRED BACK TO <br /> EXISTING CONCRETE WALL. PLEASE SEE ALSO DETAIL 3/S-1 <br /> 2. Plan Note 3/A-1 states that the manufacturer shall provide connections of the lift to the existing <br /> structure. The structural drawings are required to provide a sufficient base for the installation of <br /> these connections; this is not provided by the manufacturer. Details and calculations providing <br /> lateral anchorage and support for the new lift system should be submitted for review. The exist- <br /> ing floor system should be modified to provide a load path into the diaphragm to transfer the lat- <br /> eral forces. See IBC Sections 1603.1, 1604.1, 1604.2, and 1604.4 <br /> RESPONSE TO COMMENT 2 : PLEASE REVISED DETAIL 1 OF S-1 . PLEASE SEE ATTACHED <br /> CALCULATIONS PAGE 3 AND 4. <br /> II <br />
The URL can be used to link to this page
Your browser does not support the video tag.