Laserfiche WebLink
Ryan Hammer <br /> From: Ryan Hammer <br /> Sent: Friday, February 24, 2023 2:39 PM <br /> To: Rick Cash; 'info@kismetdesignco.com' <br /> Subject: City of Everett - 1321 Grand Ave (82209-015) - 1 st Bldg Review <br /> Good Afternoon Rick, <br /> The First Building Review of your project at 1321 Grand Ave (Permit#B2209-015) has been completed. Please find the <br /> below Building Correction letter. <br /> Revised construction-level documents should be submitted for review. Two complete sets of the revised drawings <br /> should be submitted to replace the previously submitted drawing sets. The resubmittal documents should include an <br /> itemized response letter clarifying how the review comments below have been addressed: <br /> Architectural: <br /> 1. The project appears to include new stairs. Details for the construction should be included. The stringers should <br /> comply with the joist span tables considering the net depth after notching for steps. The stair rise and run, and <br /> width, should be specified. See IRC Section R311.7. <br /> Structural: <br /> 2. Specifically to the deck itself, Page 2 states "attachment details by others" and structural sheet S1.1 states "deck <br /> by others" however it appears that deck framing plan is missing. Please provide. Framing plans and details for <br /> the deck construction should be included in the drawings. The drawings should include sections and details for <br /> stairs and guards (guards if applicable) See IRC Section R312.1.1 and R507. <br /> 3. The deck should be provided with vertical and lateral connections to the existing building per IRC Section <br /> R507.9. Details should be included in the drawings. <br /> 4. The drawings should include a note requiring cuts, notches, and holes in preservative-treated wood to be coated <br /> with a treatment complying with AWPA M4. See IRC Section R317.1.1. <br /> 5. A fastener schedule should be provided per IRC Table R602.3(1). Providing a reference to this table in the <br /> drawings does not satisfy this requirement. In addition,the make and model of proprietary hardware should be <br /> specified in the plans and details where used for connections. <br /> Review of your project will be performed in the order received once the required documentation has been <br /> submitted. Please let me know if you have questions. <br /> If you have questions,feel free to contact me directly. <br /> Best Regards, <br /> — Ryan Hammer <br /> Residential Plans Examiner I Permit Services <br /> 425.257.7299 13200 Cedar Street, 2nd Floor, Everett,WA 98201 <br /> EVERETT Phone Hours: M-F: 8:30 a.m.—12 p.m & 1 p.m.—3 p.m. <br /> everettwa.gov/permits I Facebook I Twitter <br />