Laserfiche WebLink
FOUNDATOINR' CAST-IN-PI MTETNC.RFTE ANCHTPN. 0 L 1 <br /> ‘,40.4 A•AsyA <br /> I. ADDENDUM No.4 OF THE GEOTECHNICAL REPORT WAS PREPARED FOR THE SUBJECT SHIELDING 1. CONTRACTORS SHALL CONTACT THE STRUCTURAL EOR IF CAST-IN-PLACE ANCHORS ARE MISSING OR 3 4,40\**% <br /> TR SUCTURE BY GEOENGINEERS.INC.OF 17425 NE UNION HILL ROAD.SUITE 250,REDMOND.WA.PHONE: MISPLACED AFTER CONCRETE POUR. U 1. <br /> (425)861-6000,DATED JUNE 24,2022(GEOENGINEERS FILE No.24415-001-OD).THE CONTRACTOR J' - <br /> SHALL BE FAAIUAR WITH ALL SUPPLEMENTAL REPORT INFORMATION AND RECOMMENDATIONS CONTAINED 2. CAST-IN-PLACE ANCHORS SHALL BE OF THE TYPE AND PRODUCT SPECIFIED ON THE DRAWINGS. <br /> THEREIN. REQUESTS FOR ANCHOR SUBSTITUTIONS SHALL BE SUBMITTED TO THE STRUCTURAL EOR IN WRITING ALONG ,y <br /> WITH EVIDENCE OF EQUAL OR GREATER CAPACITY FOR THE SPECIFIED CONNECTION. KApNAL 4p <br /> 2. ALL FOUNDATIONS TO BEAR ON GRANULAR COMPACTED ENGINEERED FILL PER THE PROJECT CONTRACT d, <br /> DOCUMENTS.THE CONTRACTOR IS DIRECTED TO THE GEOTECHNICAL REPORT IN THE PROJECT 3. ANCHOR EMBEDMENT SPECIFIED ON DRAWINGS IS THE'NOMINAL'ANCHOR EMBEDMENT.REFERENCE ME <br /> SUPPLEMENTAL INFORMATION FOR ADDITION.INFORMATION.EXCAVATORS FOX FOUNDATIONS SHALL BE MANUFACTURER RECOMMENDATIONS FOR THE"EFFECTIVE"EMBEDMENT. ■■ ■■ /mn <br /> OBSERVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACING OF CONCRETE FOR FOUNDATON. -m <br /> 4. CLEAN DIRT,RUST OIL,AND LOOSE PAINT/COATINGS FROM ANCHORS PRIOR TO INSTALLATION.THREADS ON <br /> 3. SOIL DESIGN CRITERIA,PER GEOTECHNICAL ENGINEER: THE PROJECTING PORTON OF THE ANCHOR ELEMENT SHALL BE PROTECTED FROM CONTAMINATION. gym$ <br /> 3.1. SOIL BEARING-2,500 PSF N'nF+ <br /> 3.1.1. 6 INCREASE ALLOWED PRESUMED CAPACITIES FOR SHORT TERM LOADS 5. INSTALL ANCHORS IN ACCORDANCE HITH THE SPACING AND EDGE CLEARANCES INDICATED ON THE s <br /> 3.2. FRICTION COEFFICIENT-0.35 DRAWINGS,BUT NOT LESS THAN THE FOLLOWING ACI 318 CHAPTER 17.7 CODE MINIMUMS: In 1 3'o iJ <br /> 3.3. PASSIVE PRESSURE-350 PCF 5.1. MINIMUM CENTER TO CENTER ANCHOR SPACING OF: <br /> 4..CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL ROUTES AND UNDERGROUND BURIED ELEMENTS. 5.1.1. FIR TIMES TIE ANCHOR METER(VOA) <br /> FOR ANCHOR THAT WILL NOT BE TORQUED. I `mar <br /> 5.1.1. SIX TIMES THE ANCHOR DIAMETER(6•DA)FOR ANCHORS THAT WILL BE TORQUED. / <br /> CONCBFTF' 5.2. MINIMUM EDGE DISTANCE MEASURED FROM THE ANCHOR CENTER UNE TO CONCRETE EDGE OF: kY <br /> 5.2.1. PER THE REINFORCING CLEAR COVER REQUIREMENTS OUTLINED IN THE CONCRETE SECTION OF <br /> 1. ALL CONCRETE SHALL.BE HARD ROCK CONCRETE MEETING REQUIREMENTS OF ACI-301.'SPECIFICATIONS 5. THESE GENERAL NOTES FOR ANCHORS THAT WILL NOT BE TORQUED. <br /> FOR STRUCTURAL CONCRETE'.MIX PROPORTIONS SHALL BE PER Ad-301.SUBMIT MIX DESIGN FOR .3. IF <br /> OSIX DICES THE ANCHOR DIAMETER(EAMA)FOR ANCHORS THAT WILL MIBE IMUMUED. <br /> REVIEW BY STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO CONSTRUCTION. 5.3. A CONFLICT SPACING <br /> CIIS IDENTIFIED THOSE <br /> BETWEEN THE MANUFACTURER D DRAWINGS RECOMMENDEDNT THEEIMTRUM EDGE DISTANCES O 8 Z A <br /> ANTI/OR SPACING AND THOSE.INDICATED ON THESE CONTACT STRUCTURAL EOR. W� O <br /> 2. NO WATER MAY BE ADDED TO CONCRETE IN THE FIELD UNLESS SPECIFlCALY APPROVED IN WRITING BY 6. ANCHORS EXPOSED TO EARTH OR WEATHER SHALL BE PROTECTED FROM CORROSION BY HOT-DIP W W m <br /> THE CONCRETE SUPPLIER IN COMUNC110N WITH THE CONCRETE MIX DESIGN. GALVANIZING OR USE OF STAINLESS STEEL.ANCHORS SHALL BE GALVANIZED FOR FASTENING GALVANIZED F-W Q RI <br /> STEEL TO CONCRETE,LINO.NUTS,WASHERS,AND OTHER HARDWARE USED WITH CAST-IN-PLACE ANCHORS Z <br /> 3. STRUCTURAL CONCRETE SHALL ATTAIN THE FOLLOWING MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS: SHALL HAVE A MATERIAL OR AN ALLOY DESIGNATION THAT IS COMPATIBLE HRH THE ANCHOR ROD/ALLOY. 7 Z N <br /> JOPE Ye SILIMP w/e AR7. CAST-IN-PLACE ANCHORS SHALL NOT BE BENT AFTER BEING INSTALLED UNLESS PERMITTED BY THE U O:Iliad <br /> FOUNDATION 6,000 psi 1-4' 0.45 OR STRUCTURAL EOR. _,- <br /> 4. ALL CONCRETE EXPOSED TO WEATHER SHALL CONTAIN 6%(A)1.5R AR ENTRAINMENT BY VOLUME.NR 8. SPECIAL INSPECTION.SHELL BE PROVIDED FOR ALL CAST-IN-PLACE ANCHORS INSTALLATION AS REOUIRED 0 <br /> ENTRAINMENT SHALL BE IN CONFORMANCE WITH ASTM C260. BY THE STRUCTURAL FOR IN THE DUALITY ASSURANCE SECTION OF THESE GENERAL NOTES.INDEPENDENT <br /> ON-SITE PROOF LOAD TESTING SHALL BE PERFORMED AS REQUIRED BY THE STRUCTURAL EOR.CONTACT TI K <br /> .1 IMF <br /> 5. COLD WEATHER PLACEMENT SHALL CONFORM TO ACI-306.HOT WEATHER PLACEMENT SHALL CONFORM TO STRUCTURAL EOR FOR NUMBER OF ANCHORS REQUIRED TO BE TESTED AND REQUIRED PROOF LOAD <br /> AG-305. MAGNITUDE. <br /> 6. MECHANICALLY VIBRATE ALL FORMED CONCRETE.DO NOT OVER-VIBRATE.PLACE CONCRETE MONOLITHICALLY <br /> BETWEEN CONSTRUCTOR OR CONTROL JOINTS.PROTECT ALL CONCRETE FROM PREMATURE DRYING. BFINFRRFING WFI. <br /> 7. CHAMFER ALL EXTERIOR CORNERS 1f UNLESS SHOWN OTHERWISE. 1. 315.REINFORG M NG STEEL SHALL CONFORM TO AS A615,GRADE 60.DETAIL <br /> L AND PLACE ACCORDING TO ACI /1I Z <br /> 8. SLUMP LIMITS MAY BE INCREASED BY ADDITION OF ADMIXTURES PROVIDED THAT THE WATER/CEMENT RATIO 2. UNLESS NOTED OTHERWISE,MINIMUM COVER SHALL BE 1 TA"FOR�5 AND SMALLER BARS,2'FOR/8 Z O <br /> OF THE ANCE w MIX DESIGN IS NOT EXCEEDED.WATER REDUCING NU ADMIXTURE SHALL 1T INAND LARGER BARS AND 3"WHEN POURED AGAINST EARTH. ALL REINFORCING STEEL SHALL BE el- Q <br /> CONFORMANCE WITH ASTM494,USED Al CONFORMANCE WITH MANUFACTURER'S INSTRUCTIONS.SUBMIT SUPPORTED ON STANDARD APPROVED ACCESSORIES SUCH AS CHAIRS,SPACERS OR TIES,HELD RIGIDLY <br /> ADMIXTURES TO ENGINEER FOR RENEW PRIOR TO CONSTRUCTOR. AND ACCURATELY IN PLACE,AND PROTECTED AGAINST DISPLACEMENT BEFORE AND DURING THE PLACEMENT <br /> 9. FIBER REINFORCING SHALL BE MASTEROBER MAC 360 FF DOSED AT 3 LB PER CUBIC YARD,OR AN OF CONCRETE. W Q <br /> ALTERNATIVE APPROVED BY THE STRUCTURAL NOR.FIBER REINFORCING SHALL CONFORM TO ASIR A1116. 3. AL LAP SPLICES,WHEN NOT DIMENSIONED ON DRAWINGS.SHALL BE MINIMUM 48 BAR DIAMETERS OR <br /> USAGE OF FIBER REINFORCING SHALL BE PER PROJECT SPECIFlGTONS. 24",WHICHEVER IS GREATER. NO MORE THAN 50R OF REINFORCING SHALL BE SPLICED AT ANY = Z <br /> 10.AT OWNER'S UPTON,BORON CARBIDE MAY BE INCLUDED IN THE CONCRETE MIX UP TO A MAXIMUM OF LOCATION,UNLESS NOTED OTHERWISE.ALL HORIZONTAL REINFORCING AT FOOTING CORNERS SHALL HAVE <br /> BENT BARS FULLY DEVELOPED TO BOTH SIDES PER DEVELOPMENT LENGTH SPECIFIED IN ACI 318.BUT VI <br /> TOR OF THE TOTALOWEIGHT PROVIDEDMETHODS,THAT MINIMUM DN MECHANICAL.BE STRENGTH,MID DURABILITY NOT LESS THAN 24" O <br /> PROPERTIES ARE OBTAINED.MEANS, AND PROCEDURES SHALL THE RESPoNSBILIry OF THE <br /> CONTRACTOR. 4. SPLICES SHALL BE MADE WHERE INDICATED ON THE STRUCTURAL DRAWINGS.SPUCES SHALL BE CONTACT 7- <br /> 11.PORTLAND CEMENT SHALL BE TYPE I OR II IN CONFORMANCE WITH ASTM C150.AGGREGATES SHALL BE IN LAP SPUCES,UNLESS NOTED OTHERWISE. F1 <br /> CONFORMANCE WTH AS I C33 AND USE CRUSHED(NOT ROUND)GRAVEL OR STONE.COARSE 5, REINFORCING STEEL SHALL NOT BE TACK WELDED FOR ANY REASON.WELDED REINFORCING BARS WILL `• I <br /> AGGREGATES SHALL NOT COGGED W.WATER SHALL BE CLEAN AND POTABLE. ONLY BE APPROVED IF EXPUCTRY SHOWN ON THE STRUCTURAL DRAWINGS OR IF WRITTEN APPROVAL IS <br /> 12.COMPRESSIBLE MATERIAL USED TO PROVIDE A MEDIUM TO UNIT LOAD TRANSFER BeI1seEN EXISTING GIVEN BY TIE ENGINEER. W <br /> FOOTINGS AND THE NEW MAT FOUNDATION SHALL BE OF RE FOOLD POLYSTYRENE OF A CELLULAR MOLDED 8. DOWELS AND OTHER MISCELLANEOUS STEEL EMDEDOED ITEMS SHALL BE LOCATED AND HELD IN SPECIFIED Z LLJ M <br /> TOPE YWTH A DENSITY OF 1.5+/-0.25 POUNDS PER CUBIC OR AN APPROVED ALTERNATIVE. POSITION PRIOR TO PLACEMENT OF CONCRETE AND SHALL NOT BE PUSHED INTO CONCRETE FOLLOWING �/ 3 CA <br /> O <br /> COMPRESSIBLE MATERIAL SHALL BE ADEQUATE TO SUPPORT THE WEIGHT OF THE WET CONCRETE. CONCRETE POUR.IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE EMBEDDED ITEMS NOT SHOWN W }N ED <br /> IN THE STRUCTURAL DRAWINGS. U F A <br /> FORMWORK.SHORING.AND BRACING 7. ALL REINFORCING BENDS SHALL BE MADE COLO.BARS SHALL NOT BE UN-BENT AND RE-BENT.FIELD Z ~�♦H-W N Q <br /> I. THESE DRAWINGS REPRESENT THE FINISHED STRUCTRUE.THEY DO NOT INDICATE THE METHOD OF BENDING OF REBAR SHALL NOT BE ALLOWED UNLESS SPECIFICALLY NOTED.NO BARS PARTIALLY EMBEDDED V N Z=3 <br /> CONSTRUCTION.THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS,METHODS, IN HARD CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY DETAILED OR APPROVED BY THE 0 ILA' <br /> TECHNIQUES,SEQUENCES,PROCEDURES,LAGGING,SHORING,BRACING,FORA-WORK ETC.AS REQUIRED ENGINEER. =V r <br /> • <br /> FOR THE PROTECTOR OF LIFE AND PROPERTY DURING CONSMUCRON.FORMS SHALL BE DESIGNED BY J W Z t <br /> THE CONTRACTOR. BRACING SHALL BE PROVIDED AS REQUIRED OR UNTIL THE CONCRETE HAS REACHED B. DOWELS BETWEEN FOOTINGS AND WALLS OR COLUMNS SHAL BE THE S ME GRADE,SIZE,SPACING AND O M <br /> ITS SPECIFIED 28-DAY STRENGTH.FORMWORK,SUPPORTS,AND SHORING SHALL PROVIDE FINISHED NUMBER AS THE SPECIFIED VERTICAL REINFORCING,UNLESS NOTED OTHERWISE. w I-O LA P W <br /> CONCRETE SURFACES AT ALL FACES:LEVEL,PLUMB,AND TRUE TO DIMENSIONS AND ELEVATIONS SHOWN >> <br /> IN THE DRAWINGS. 9. APPROVED REBAR COUPLERS MAY BE USED AT THE CONTRACTOR'S OPTION TO AID PLACEMENT OF DOWELS = O-_ <br /> 2. TOLERANCES FOR CONCRETE FORMWORK SHALL CONFORM TO ACT 117,STANDARD TOLERANCES FOR THROUGH FORMS.MECHANICAL SPACES.SHALL DEVELOP 125X OF THE TENSILE STRENGTH OF THE REBAR. <br /> CONCRETE CONSTRUCTION AND MATERIALS,UNLESS OTHERWISE SPECIFIED. THE CONTACTOR SHALL 10.ALL BARS SHALL BE MARKED SO THEIR IDENTFlCATWHENTHE FINAL IN-PLACE <br /> ON CAN BE MADE <br /> ENGAGE A UCENSE TH <br /> SURVEYOR TO VERIFY THAT WORK IS WITHIN SPECIFIED TOLERANCES UNLESS WRITTEN INSPECTION OCCURS. <br /> AUTHORIZATION IS OBTAINED FROM E ARCHITECT AND EOR TO PROVIDE TOLERANCE CONTROL USING THECT <br /> CONTRACTOR'S OWN MEANS PRIOR TO BEGINNING WORK. ANCHOR REINFORCING. 11 <br /> n <br /> 3. CONSTRUCTION MATERIALS SHALL BE UNIFORMLY SPREAD OUT SUCH THAT DESIGN LIVE LOAD PER SQUARE I. ANCHOR REINFORCING SHALL.CONFORM TO TIE REQUIREMENS OF THE RdNFORDNG STEEL SECTION OF W <br /> FOOT AS NOTED HEREIN IS NOT EXCEEDED. THESE GENERAL NOTES. F- <br /> 0 <br /> 2. TENSION ANCHOR REINFORCING: Z <br /> 2.1. PLACE ANCHOR REINFORCING AS CLOSE AS PRACTICABLE TO THE.ANCHOR.BUT NOT MORE THAN <br /> HALF THE EFFECTIVE EMBEDMENT DEPTH FROM THE ANCHOR CENTERUNE. --I <br /> 2.2. ANCHOR REINFORCING SHALL NOT BE URGER THAN#5 BAR(S). Q <br /> d. <br /> PREMANUFACTQBER CONNECTION HARDWARE. W <br /> W <br /> 1. CONNECTIONBEG HARDWAREANIZ A BY THE SIMPSON MADE <br /> OF SON RESIST N CA.ALL STEEL COWISE S 0 <br /> SHALL GALVANIZED OR BY SOME METHOD MADE CORROSION RESISTANT,UNLESS OTHERWISE INDICATED. x <br /> 2. EOUNALENT EQUIPMENT BY OTHER MANUFACTURERS MAY BE SUBMITTED TO THE FOR FOR APPROVAL, JOB No. <br /> PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. <br /> 3. FASTENERS SHALL BE OF ME SAME MATERIAL OR PROTECTNE COATING AS THE CONNECTORS,DO NOT 2202-0023 <br /> MIX DIFFERING METALS IN THE SANE CONNECTION. DRAWN CRACKED <br /> V. ALL HARDWARE SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS, NRW WITS <br /> UNLESS NOTED OTHERWISE. <br /> DATE 07/14/22 <br /> REASONS <br /> SHEET SF1 <br /> • <br /> 2 OF 21 <br />