Laserfiche WebLink
VERETT <br />0 <br />Permit Number: P2305-029 <br />Applied: 5/17/2023 <br />Issued: 5/17/2023 <br />Status: PERMIT ISSUED <br />Parent Permit: B2302-090 <br />Parent Project: <br />Details <br />Permit Inspections <br />City of Everett <br />Approved:5/17/2023 <br />Finaled: <br />Description: AFH - INSTALL NEW TOILET, SINK, & SHOWER <br />Site Address: 6220 EAST DR <br />City, State Zip Code: EVERETT, WA 98203 <br />Applicant: NIRVANA PLUMBING INC <br />Owner: SENBETO GETAHUN & WORKNEH YENENESH <br />Contractor: NIRVANA PLUMBING INC <br />SCHEDULED DATE <br />COMPLETED DATE <br />TYPE <br />INSPECTOR <br />RESULT <br />REMARKS <br />5/18/2023 <br />5/18/2023 <br />PLUMB 03-ROUGH <br />JASON <br />CORRECTION <br />see notes <br />IN <br />MORRISSEY <br />REQUIRED <br />Notes: <br />ANDRES SANCHEZ 206-356-6510 <br />- Insulate all water distribution piping with R-3 pipe insulation per the UPC 312.6 Freezing Protection*** No water, soil, or waste pipe shall be installed <br />or permitted outside of a building, in attics or crawl spaces, or in an exterior wall unless, where necessary, adequate provision is made to protect such <br />pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to a minimum R-3- Support all pex lines in <br />crawlspace every 32" on the horizontal per the UPC table 313.3 Hangers and Supports.- Support ABS pipe in crawlspace every 4' horizontally per the <br />UPC table 313.3 Hangers and Supports.*** Obtain mechanical permit for range and new bathroom exhaust fans and ducting per the IMC 106.1*** <br />Obtain electrical permit for adding circuits in new bathroom per the NEC and WAC rules.Plumbing rough cannot be signed off until all permits have <br />been obtained. <br />- Insulate all water distribution piping with R-3 pipe insulation per the UPC 312.6 Freezing Protection*** No water, soil, or waste pipe shall be installed <br />or permitted outside of a building, in attics or crawl spaces, or in an exterior wall unless, where necessary, adequate provision is made to protect such <br />pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to a minimum R-3- Support all pex lines in <br />crawlspace every 32" on the horizontal per the UPC table 313.3 Hangers and Supports.- Support ABS pipe in crawlspace every 4' horizontally per the <br />UPC table 313.3 Hangers and Supports.*** Obtain mechanical permit for range and new bathroom exhaust fans and ducting per the IMC 106.1*** <br />Obtain electrical permit for adding circuits in new bathroom per the NEC and WAC rules.Plumbing rough cannot be signed off until all permits have <br />been obtained. <br />6/2/2023 <br />6/2/2023 <br />PLUMB 03-ROUGH <br />JASON <br />APPROVAL <br />see notes <br />IN <br />MORRISSEY <br />Notes: <br />GETAHUN 702-336-1576 <br />- Rough DWV and water ok for new and existing bath. <br />6/6/2023 <br />6/6/2023 <br />PLUMB 06A-SHOWER <br />JEFF M RHODE <br />APPROVAL <br />Notes: <br />I <br />Printed: Tuesday, 25 July, 2023 1 of 2 rk <br />SUPERION <br />