My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-202 2023-10-19
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-202
>
3003 W CASINO RD BLDG 40-202 2023-10-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2023 1:09:53 PM
Creation date
10/3/2023 11:13:57 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-202
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MECHANICAL GENERAL ABBREVIATIONS HVAC GENERAL NOTES-2018 WA STATE <br /> s <br /> ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME L Z E <br /> R AC AIR CONDITIONING UNIT FCU FAN COIL UNIT NOM NOMINAL 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAYBE REQUIRED.THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO � � m <br /> m AFF ABOVE FINISHED FLOOR FD FIRE DAMPER NTS NOT TO SCALE VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. Z Q d <br /> 3U <br /> m ALU AIRHANDLINGUNIT FLA FULL ON BOTTOM <br /> OBD OPPOSED BLADE DAMPER 2. MATERIALS,METHODS,AND INSTALLATION ANDSHALLORDINANCES. <br /> WITH THE PROVISIONS OFTHE 2018 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE,INTERNATIONAL BUILDING CODE,INTERNATIONAL 5 0_ <br /> AL ALUMINUM FOB FLAT ON BOTTOM OD OUTSIDE DIMENSION FIRE CODE 2018 WSEC,AND LOCAL CODES AND ORDINANCES. L F�E <br /> 3 BAS BUILDING AUTOMATION SYSTEM FOD FLAT M TOP POC POINT OF CONNECTION 1 <br /> BDD BACK DRAFT DAMPER FSD FIRE SMOKE DAMPER PRV PRESSURE REDUCING VALVE 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 60F THE 2018 IMC AND WITH CURRENT SMACNA STANDARDS.EARTHQUAKE BRACE ALL DUCTS 28"DIA AND LARGER WHICH <br /> 'g BI BLACKIRON GALV GALVANIZED PVC POLYVINYLCHLORIDE ARE SUSPENDED MORE THAN I2"BELOW STRUCTURAL SYSTEM. - <br /> BOD BOTTOM OF DUCT GC GENERAL CONTRACTOR REDO REQUIRED 4. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS,PER 2018 WASHINGTON STATE ENERGY CODE,COMMERCIAL PROVISIONS O <br /> w� 8T BOTTOM GENX GENERATOR EXHAUST RPBA REDUCED PRESSURE BACKFLOW ASSY R <br /> BTU BRITISH THERMAL UNITS GLVNL GALVANNEAL RTU ROOFTOP UNIT -DUCT WRAP,WHERE INDICATED,SHALL BE 0.75 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM.FOIL VAPOR BARRIER. O vA <br /> g BTUH BRITISH THERMAL UNITS PER HOUR GPM GALLONS PER MINUTE SA SUPPLY AIR <br /> CATl CATEGORY ONE VENT GREASE GREASE DUCT SO SMOKE DAMPER -SOUND LINING,WHERE INDICATED,SHALL BE 1-1.5 LBICU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM. Q J 3I' <br /> CAT4 CATEGORY FOUR VENT OWE GYPSUM WALL BOARD SL SOUND LINED — m o <br /> m CFM CUBIC FEET PER MINUTE HP HORSE POWER,HEAT PUMP SM SHEET METAL -DUCT BOARD,WHERE INDICATED,SHALL BE I"RIGID FRK FACED EI 475 FIBERGLASS DUCT BOARD SYSTEM,UL 181 LISTED AS A CLASS I AIR DUCT. U Q o <br /> CPVC CPVC MATERIAL HVAC HEATING,VENTILATION AND AIR COND. SP STATIC PRESSURE <br /> DB DUCTBOARD HX HEAT EXCHANGER SS STAINLESS STEEL -SUPPLY DUCT WHICH CONVEYS SUPPLY AIR AT TEMPERATURES LESS THAN 55 DEG F OR GREATER THAN 105 DEG F WHEN LOCATED IN CONDITIONED SPACE SHALL BE INSULATED WITH A MINIMUM OF C LL <br /> DDC DIRECT DIGITAL CONTROLS ID INSIDE DIMENSION SUSP SUSPENDED R-3.3,WHEN LOCATED IN UNCONDITIONED SPACE R-6 AND WHEN LOCATED OUTSIDE THE BUILDING R-8(CLIMATE ZONE 4)OR R-12(CLIMATE ZONE 5)PERWSEC C403.10.1 AND TABLE C403.10.1.2. C �a <br /> DEMO DEMOLISH LAT LEAVING AIR TEMPERATURE T THERMOSTAT DUCTWORK EXPOSED TO VIEW WITHIN A ZONE THAT SERVES THAT ZONE IS NOT REQUIRED TO BE INSULATED. <br /> DIFF DIFFUSER LBS POUNDS TOO TOP OF DUCT <br /> DMPR DAMPER LWT LEAVING WATER TEMPERATURE TV TURNING VANES -OUTSIDE AIR DUCT INSULATION INSIDE THE BUILDING SHALL BE INSULATED PER C403.10.1 AND TABLE C403.10.1.1 AS FOLLOWS: <br /> ON DOWN MAT MIXED AIR TEMPERATURE TYP TYPICAL IF-2800 CFM INSULATE TO R-16 UPSTREAM OFAUTOMATIC SHUTOFF DAMPERSAND R-8(CLIMATEZONE 4C)OR R-12(CLIMATE ZONE 5B)DOWNSTREAM OFAUTOMATIC SHUTOFF DAMPERS. <br /> E EXISTING MBH ONE THOUSAND BTUH UNO UNLESS NOTED OTHERWISE IF<2800 CFM INSULATE TO R-7. <br /> EAT EN TERING AIR TEMPERATURE MCA MINIMUM CIRCUIT AMPACITY VAV VARIABLE AIR VOLUME <br /> EC EGGCRATE MD MOTORIZED DAMPER VD VOLUME DAMPER <br /> s EER ENERGY EFFICIENCY RATIO MIN MINIMUM VFD VARIABLE FREQUENCY DRIVE 5, FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER,11/2-FIBERGLASS INSULATION,AND NON-PERFORATED INTERIOR LINER WITH WIRE HELIX.DUCT SHALL BE A UL 181 LISTED CLASS <br /> EF EXHAUST FAN M-M MACDONALD-MILLER W DUCT INSULATION WRAP 1 AIR DUCT.FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12'IN LENGTH UNLESS NOTED OTHERWISE. <br /> ELEV ELEVATION NC NORMALLY CLOSED W/ WITH <br /> ESP EXTERNAL STATIC PRESSURE NIC NOT IN CONTRACT WELD WELDED 6, PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2018 IBC. <br /> EWT ENTERING WATER TEMPERATURE NO NORMALLY OPEN 0 VOLTAGE PHASE&DUCT DIAMETER <br /> ]. HVAC EQUIPMENT,VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS.UNLESS SHOWN ON ARCHITECTURAL DRAWINGS,REQUIRED ACCESS PANELS SHALL BE <br /> PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR.MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE I8"X18". <br /> 8, MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. <br /> HVAC SYSTEM ABBREVIATIONS <br /> S. WITHIN W DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE,RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER.RECORD DRAWINGS HALL INCLUDE AS 03/01/2023 <br /> 7SAGLVNL <br /> FULL NAME ABBV FULL NAME ABBV FULL NAME A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT,GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM,INCLUDING SIZES,AND THE TERMINAL <br /> COMBUSTION AIR EA AL EXHAUSTALUMINUM OA OUTSIDEAIR AIR AND WATER DESIGN FLOW RATES. <br /> SUPPLY AIR LP EASS EXHAUST SS 304 OA-KOOL OUTSIDE AIR KOOLDUCT <br /> SUP PLY AIR LP KOOLDUCT EA AL WELD EXHAUST ALUMINUM WELDED RLF RELIEFAIR 10. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE:SUBMITTAL DATA,NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY,HVAC <br /> SUP PLY AIR LP ALUMINUM EA GALV WELD EXHAUST GALV WELDED RA RETURN AIR CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. F <br /> SUP PLY AIR LP SS 30428 EA GLVNL WELD EXHAUST GALVANNEAL WELDED DB DUCTBOARD Q <br /> SUP PLY AIR LP ALUMINUM WELDED EA SS WELD EXHAUST SS 304 WELDED FLU-CAT1 FLUE VENT-CATEGORY 1 11. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH 2018 WASHINGTON STATE ENERGY CODE(WSEC),COMMERCIAL PROVISIONS AND SECTION C408. <br /> LD SUPPLY AIR MP GALV WELDED EA BI GREASE EXHAUST GREASE BLACK IRON WELD FLU-CAT4 FLUE VENT-CATEGORY 4 <br /> WELD SUP PLY AIR MP GALVANNEAL WELD EA GALV GREASE EXHAUST GREASE GALV WELDED FLU-CPVC FLUE VENT-CPVC MATERIAL 12. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER <br /> SA SS WELD WELDED SUPPLY AIR LP SS 30426 EA GALV GREASE EXHAUST GREASE SS 304 WELDED FLU-S8 FLUE VENT-SHOP BUILT SS 304 <br /> EA EXHAUSTAIR MUA MAKE-UP AIR FLU-GALV FLUE VENT-SHOP BUILT GALV 13. DAMPERS USED FOR OUTDOOR AIR INTAKE,EXHAUST,OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1-W.G.(PER AMCA STANDARD 5001)):MOTORIZED DAMPERS:4 <br /> CFM/S.F.GRAVITY DAMPERS:20CFM/S.F.(40 CFM/S.F.FOR DAMPERS SMALLER THAN 24'IN EITHER DIMENSION)PER 2018 WSEC C403.78.3. <br /> 14. OUTSIDE AIR INTAKE,EXHAUST,AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED(FAIL CLOSED)PER WSEC,COMMERCIAL PROVISIONS,2018 WSEC SECTION 0103.7.8. <br /> EXCEPT AS ALLOWED BY WSEC. <br /> PIPING SYSTEM ABBREVIATIONS 15. M TERI&$WITHIN PLENUMS$HALL BE NONCOMBUSTIBLE OR$HALL BE LISTED AND LABELED AS HAVING A PLANE SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT <br /> MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723,EXCEPT AS NOTED IN SECTION 602.2.1 OF THE 2018 IMC. <br /> ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME 6i <br /> C CONDENSATE INDIRECT DRAIN HHWR HEATING HOT WATER RETURN NGV NATURAL GAS VENT z <br /> 0 <br /> CA AIR COMPRESSED HHWS HEATING HOT WATER SUPPLY PA AIR PNEUMATIC y <br /> COW R CONDENSER WATER RETURN HPC STEAM CONDENSATE HIGH PRESS PC CONDENSATE PUMPED j <br /> COWS CONDENSER WATER SUPPLY HPS STEAM HIGH PRESS PCHR CHILLED WATER(PROCESS)RETURN <br /> CHRV CHILLER RELIEF VENT HRR HEAT RECOVERY RETURN PCHS CHILLED WATER(PROCESS)SUPPLY LEGAL DESCRIPTION <br /> CHWR CHILLED WATER RETURN HRS HEAT RECOVERY SUPPLY RGAS REFRIGERANT HOT GAS <br /> CHI CHILLED WATER SUPPLY LPC STEAM CONDENSATE LOW PRESS RLIQ REFRIGERANT LIQUID ILNW <br /> CEL NUMBER:28041000100200 N W <br /> CLN STM STEAM CLEAN LPG LIQUID PROPANE RSUC REFRIGERANT SUCTION r <br /> CLR CLOSED LOOP WATER RETURN LPS STEAM LOW PRESS SCHR CHILLED WATER(SECONDARV)RETURN AL DESCRIPTION: SEC I0 TWP 28 RGE 04 Ei/2 OF SEC EXC CASINO RD(AKA S.R.526)&EXC ADDN'LRM'TO ST OF WA PER WD REC AF NO 8410020045&CORRD AF NO 93OB311309 TGW FDP-TH PTN N1/2 CLS CLOSED LOOP WATER SUPPLY LTCR CHILLED WATER(LOW TEMP)RETURN SCHS CHILLED WATER(SECONDARY)SUPPLYCOMB-PVC AIR COMBUSTION PVC LTCS CHILLED WATER(LOW TEMP)SUPPLV SCV STEAM CONDENSATE VENT 114&SE1/4 NI LY ELY OF ELN OF BN RR TGW NEI/4 SW1I4 EXCW330FT OF 792FT THOF&LESS PTN WAN BNRR&TGW PTN SE1/4 SW1/4 LV NLV OF RM/LN CO R1)AKA CASINO R1) 0 <br /> CRYV CRYO VENT MPC STEAM CONDENSATE MEDIUM PRESS SPC STEAM CONDENSATE PUMPED <br /> FOC FUEL OIL SECONDARY CONTAINMENT MPS STEAM MEDIUM PRESS SV STEAM VENT <br /> F FUEL OIL FILL MI MAKE-UP WATER VAC VACUUM <br /> FOR FUEL OIL RETURN NG-2PSI NATURAL GAS 2PSI VAC-E VACUUM EXHAUST <br /> FOS FUEL OIL SUPPLY NG-5PSI NATURAL GAS 5PSI VRFG VRF HOT GAS <br /> FOV FUELOILVENTS NG-CONDUIT NATURAL GAS CONDUIT VRFL VRF HIGH PRESS LIQUID CONTACT LIST <br /> GENX GENERATOR EXHAUST NG-H NATURAL GAS HIGH PRESS VRFS VRF LOW PRESS SUCTION <br /> GLWR GLYCOL WATER RETURN NG-L NATURAL GAS LOW PRESS TITLE NAME COMPANY PHONE NUMBER EMAIL <br /> GLWS GLYCOL WATER SUPPLY NG-M NATURAL GAS MEDIUM PRESS PROJECT DESIGN ENGINEER KEVIN KRUEGER MACDONALD MILLER 206407-2632 KEVIN.KRUEGER@MACMILLER.COM r <br /> ACCOUNT MANAGER ROB PAINTER MACDONALD MILLER 206.7684122 ROB.PAINTER@MACMILLER.COM W <br /> rn <br /> r z <br /> � z <br /> EL <br /> EL rn <br /> w <br /> DRAWING SHEET INDEX - HVAC a <br /> NUMBER TITLE N <br /> TM0.01 SCHEDULES LL <br /> TM0.02 SCHEDULES Q <br /> TM0.01S SITE PLAN L <br /> TM2.01 1ST FLOOR PLAN-HVAC I— <br /> TM6.01 DETAILS-HVAC <br /> W <br /> L11 <br /> Y Lu <br /> SCOPE OF WORK Q <br /> -INSTALLNEWMAKEUPAIR FAN TO SERVE E%ISTINGKITCHEN 2i W <br /> -INSTALL NEW ELECTRIC DUCT HEATER TO TEMPER MAKEUP AIR <br /> -INSTALL ASSOCIATED DUCTWORK AND GRILLES FOR MAKEUP AIR SYSTEM z <br /> LLJ <br /> Z ~ <br /> 0 <br /> `s N w <br /> o U <br /> z0 Lur , <br /> N2wcoq° NVQ O <br /> Q <br /> HU_�� LL <br /> W o <br /> K <br /> 2 � <br /> �MMM�MNw 4 W ecro^_ ♦c♦�^� <br /> POSSESSION SOUND. 5 <br /> EK KRUEGER 03-01-23 <br /> vo <br /> CHECKED PUOTTCD <br /> WMUKS HARGROVE 03.01-23 <br /> LTEOM�RRI��CRyEK K cAD. ISSUEDATE <br /> 8p M HAGBERG 03-01-23 <br /> 0 <br /> 1 N DRAWINDNDMBER <br /> SITE c O <br /> 1924-73234146-00 <br /> HWY 526 SHEET NUMBER. <br /> KASCH Q <br /> BIG ygJ. PAINE PARK <br /> GULCH T M 0.01 <br /> N <br /> PARK FIELD <br /> `n 5 <br /> _ N VICINITY MAP <br /> NO SCALE <br /> F <br /> 3� Page 9 <br />