A B I C D E F G I H <br /> COMBINER BOX PANEL SIZE CALCS CONDUCTOR SCHEDULE <br /> NUMBER OF NUMBER OF NORMINAL OUTPUT COMBINED CONDUCTORS GROUND <br /> TOTAL 125% TOTAL BREAKER SIZE RATING <br /> CIRCUIT# MODULES MICROINVERTERS CURRENT TOTAL CURRENT FOR HM-1200 600 300 WIRES IN MINIMUM MINIMUM <br /> CIRCUIT 1 1 of 3 _ 1.23A _ 1.54A TAG ID TYPE,MATERIAL TYPE,MATERIAL <br /> 1 1 X 1.23A - - INVERTE NUMBERR OF OMINAL OUTPU OMBINED CONDUIT WIRE SIZE WIRE SIZE <br /> CIRCUIT 1(2 of 3) 2 1 X 2.46A = 2.46A x 1.25 = 3.08A = 10.86A = 20A TYPE INVERTERS CURRENT TOTAL TOTAL <br /> CIRCUIT 1(3 of 3) 4 1 x5.OA = 5.00A x 1.25 = 6.25A HM-1200 2 X 5.0A - 10.00A A* 6 #12 AWG PV CABLE,CU #6 AWG BARE,CU <br /> CIRCUIT 2(1 of 2) 2 1 X 2.46A = 2.46A x 1.25 = 3.08A 9,33A = 20A HM-600 2 X 2.46A = 4.92A = 16.15A B 5 #12AWG THWN-2,CU #8 AWG THWN-2,CU <br /> CIRCUIT 2(2 of 2) 4 1 5.OA = 5.00A x 1.25 = 6.25A HM-300 1 X 1.23A = 1.23A <br /> C 3 #8 AWG THWN-2,CU #B AWG THWN-2,CU <br /> D^ 4 #8 AWG THWN-2,CU #8 AWG THWN-2,CU <br /> LOAD CALCS-TOTAL AMPS AVAILABLE TAG A CABLE WILL BE RUN THROUGH ATTIC WHERE POSSIBLE **TAG D ONLY IF APPLICABLE* <br /> BUS RATING 120% 1 1 TOTAL I MAIN BREAKER - MAX BREAKER SIZE BREAKER SIZE CALLS <br /> 200A X 1.2 - 240 200A 40A I MAX AC OPERATING CURRENT 125% TOTAL BREAKER SIZE <br /> 16.15A lxl 1.25 1 x I 20.19A 1=1 25A <br /> 1 ZNSHINE ZXM6-NH120-360M MODULE 2 ZNSHINE ZXM6-NH120-360M MODULES 4 ZNSHINE ZXM6-NH120-360M MODULES <br /> WITH HOYMILES HM-300 MICRO WITH HOYMILES HM-600 MICRO WITH HOYMILES HM-1200 MICRO <br /> INVERTER INVERTERS INVERTERS <br /> (1 OF 3) (2 OF 3) (3 OF 3) <br /> ------------- ---- ------ <br /> I <br /> N (11 (21 (11 (4(2 (31 (21 (11 I Iv <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> -ti -ti -ti I <br /> I <br /> I <br /> I UTILITY <br /> 2 ZNSHINE ZXM6-NH120-360M MODULES 4 ZNSHINE ZXM6-NH120-360M MODULES I SERVICE <br /> WITH HOYMILES HM-600 MICRO WITH HOYMILES HM-1200 MICRO I 120/240V <br /> INVERTERS INVERTERS I SINGLE PHASE <br /> u <br /> co (21 (11 (41 (31 (21 (11 II w <br /> II <br /> II O <br /> II <br /> II <br /> II 2 <br /> II (N)240V/60A PV <br /> __ II 125A LOAD CENTER, <br /> NEMA 3R RATED 200A RATED <br /> DI <br /> AC DISCONNECT g ( 200A MAIN SERVICE <br /> II <br /> IIMAIN PANEL <br /> 240V/30A NEMA 3R DlscoNNEc <br /> II NON-FUSIBLE, <br /> II VISIBLE-LOCKABLE <br /> (E)LOADS <br /> II LABELED <br /> II 20A <br /> II 20A <br /> (N)PV OCPD <br /> 2P-25A <br /> II <br /> II <br /> ON <br /> I I <br /> I <br /> L --- <br /> NEMA3R RATED u 3 25A LOAD-SIDE FACILITY GROUND <br /> JUNCTION BOX:SHALL SOLAR OCPD GROUND ROD <br /> COMPLY W/NEC 110.3 (Opposite end of the main disconnect <br /> &314.6 VxD on the busbar-NEC 705.12(B)(3) <br /> NOTES: <br /> LO 1. 200A UTILITY METER GLOBE ONLY.(EXISTING) <br /> 2. 200A LOAD CENTER.(EXISTING) <br /> 3. 30A RATED NON-FUSED LOCKABLE AC DISCONNECT. <br /> (NEW) <br /> 4. 125A RATED COMBINER PANEL.(NEW) <br /> ALL CONDUIT SIZES ARE MINIMUM SIZES <br /> ALL WIRE SIZES ARE FOR COPPER WIRE <br /> DRAWN BY: DRAWING SCALE: <br /> CONFIDENTIAL-THE INFORMATION CONTAINED CDR NOT TO SCALE <br /> IN THIS PACKET AND SUBSEQUENT CUTSHEETS Jennifer A Bowen DATE: DESIGN <br /> SO <br /> SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER <br /> L G r.-' N ANYONE OUTSIDE SOLGEN POWER. NEITHER 5715 BEDFORD ST, 14/09/2023 <br /> SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 <br /> P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN 4003 Friday Ave, Everett, WA 98201 PAGE# <br /> CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 <br /> RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV <br /> CONSENT FROM SOLGEN POWER. <br />