My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY ZAP ENERGY 2023-10-25
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
ZAP ENERGY
>
2300 MERRILL CREEK PKY ZAP ENERGY 2023-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 11:56:34 AM
Creation date
10/5/2023 12:58:07 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. Ceiling Mount - Ceiling mounted smoke detectors shall be at least 4 inches from a ❑ ❑ ❑ <br />wall or ceiling obstruction. <br />7. Supply/Return Air Diffuser- Smoke detectors shall not be located within 3 feet of ❑ ❑ ❑ <br />a supply or return air diffuser, nor in a strong air stream from a supply diffuser at <br />any distance. <br />8. Listings - All smoke detectors shall be located in conditioned space or be listed for ❑ ❑ ❑ <br />non -conditioned spaces (outside, parking decks, areas with low or high <br />temperatures). <br />9. Dust Covers - Verify all dust covers have been removed. ❑ ❑ ❑ <br />Duct Smoke Detectors: <br />PASS FAIL N/A <br />10 Sample Test - The fire inspector will select a sample of Duct Smoke Detectors at ❑ ❑ ❑ <br />random to be tested by using smoke or a listed aerosol. Minimum of one per floor <br />and no less than 10% of the devises shall be tested. (Duct Smoke Detectors shall <br />be programmed to be a supervisory condition at the FACP.) <br />11. HVAC Shutdown - Verify that HVAC shutdown is operational. After the initial test ❑ ❑ ❑ <br />and verification, it is acceptable to activate the HVAC bypass to avoid excessive <br />restarting. <br />12. Close Upon Activation - All remaining duct smoke detectors not tested shall be ❑ ❑ ❑ <br />inspected to verify that they close upon activation of the fire alarm system. <br />13. Access Door - At each duct detector a 12"x12" minimum access door, hinged or ❑ ❑ ❑ <br />latched type, is provided to facilitate sampling tube inspection and cleaning. Doors <br />shall have a label that reads: FIRE/SMOKE DAMPER, SMOKE DAMPER OR FIRE <br />DAMPER. <br />14. Air Flow Decal -Air flow direction is permanently indicated on the duct by stencil ❑ ❑ ❑ <br />or decal, to help assure the sampling tubes are installed and maintained in the <br />correct orientation. <br />15. Intake Tube - Intake tube has its holes/slots facing into the air stream, and a ❑ ❑ ❑ <br />stopper installed to seal its far end. <br />Heat Detectors: <br />PASS FAIL N/A <br />16. Sample Test - The fire inspector will select a sample of Heat Detectors at random ❑ ❑ ❑ <br />to be tested. (minimum of one per floor and no less than 10% of the devises shall <br />be tested) <br />Fire Marshal's Office 425.257.8100 1 everettwa.gov/fire I INFORMATION HANDOUT C-5 4.13.2020 1 Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.