Laserfiche WebLink
(E)POTTER <br />The Symbol of Protection <br />Features <br />• Single module with dual contact monitoring inputs <br />• Two (2) Class B or one (1) Class A monitoring inputs <br />• SLC Class A, Class X & Class B <br />• Mounts in a standard 4" or double gang box <br />• Wiring terminals accessible when mounted in box <br />• All wiring terminals accept 22 to 12 AWG <br />• Product includes a 5 year warranty <br />• UUKL Listed for Smoke Control <br />PAD100-DIM <br />Dual Input Module <br />1A <br />J <br />NOTE: This addressable module does not support 2-wire smoke <br />detectors. <br />F M � U <br />APPROVED <br />Description <br />The PAD100-DIM uses one (1) SLC loop address when monitoring <br />two (2) Class B circuits or one (1) Class A circuit. The module mounts <br />on either a 4" square or double gang box. The module is capable <br />of monitoring two (2) separate class B circuits making it ideal for <br />monitoring sprinkler waterflow and valve tamper switches when they <br />are located in the same proximity. The PAD 100-DIM includes one red <br />LED to indicate the module's status. In normal condition, the LED <br />flashes when the device is being polled by the control panel. When an <br />input is activated, the LED will flash at a fast rate. <br />Application <br />The PAD 100-DIM is compatible with Potter's IPA and AFC/ARC <br />series addressable fire alarm control panels. The PAD100-DIM is an <br />interface module used to monitor dry contact devices such as sprinkler <br />waterflow, valve tamper switches, or conventional pull stations. The <br />module is capable of monitoring two separate Class B or one Class A <br />circuits. <br />Setting the Address <br />Each addressable SLC device must be assigned an address. The <br />address is set using the DIP switch located on the PAD 100-DIM. When <br />the PAD 100- DIM is used to monitor two individual Class B circuits <br />a single device address is assigned, each input is then identified as a <br />sub -point of the module address. For example, if the address number <br />is assigned as "8", the first input will be "8.1" and the second input <br />will be "8.2". <br />Before connecting a device to the SLC loop, take the following <br />precautions to prevent potential damage to the panel or device: <br />1. Power to the device is removed. <br />2. Field wiring is correctly installed. <br />3. Field wiring has no open or short circuits. <br />Technical Specifications <br />Operating Voltage <br />24.OV <br />Max SLC Standby <br />240µA <br />Current <br />Max SLC Alarm <br />240µA <br />Current <br />Max Wiring Resistance <br />100 S2 <br />of IDC <br />Max Wiring <br />1 µF <br />Capacitance of IDC <br />EOL Resistor <br />5.1 K D <br />Operating Temperature <br />Range <br />32 to 120°F (0 to 49°C) <br />Operating Humidity <br />Range <br />0 to 93% (non -condensing) <br />Max no. of Module Per <br />127 units <br />Loop <br />Dimensions <br />4.17" (106mm)L x 4.17" <br />(I06mm)W x 1.14" (29mm)D <br />Mounting Options <br />Standard 4" Square or <br />Double Gang Box <br />Shipping Weight <br />0.6 lbs <br />Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br />8830082 - REV D • 12/18 PAGE 1 OF 2 <br />