My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY ZAP ENERGY 2023-10-25
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
ZAP ENERGY
>
2300 MERRILL CREEK PKY ZAP ENERGY 2023-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 11:56:34 AM
Creation date
10/5/2023 12:58:07 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(E)POTTER <br />The Symbol of Protection <br />Features <br />• PSN-64 has 6 amps regulated with 4 outputs <br />• PSN-106 has 10 amps regulated with 6 outputs <br />• May be configured as up to three class "A" Style "Z" <br />notification circuits <br />• Two Trouble relays (5A at 30VDC) General System Trouble <br />(programmable for AC delay) Low AC Trouble with optional <br />delay settings <br />• Diagnostic LED's Status LED's for Active NAC and NAC <br />Trouble conditions. <br />• Quadrasync feature synchronizes strobes from AMSECO, <br />Gentex, Cooper -Wheelock and System Sensor. <br />• Configurable output circuits (DIP switch sets options for each <br />circuit) <br />• Reference EOL allows 2K — 27K EOL value to be used <br />• Pass Thru mode allows the outputs to match the input signal <br />from FACP <br />Description <br />The PSN series of notification power supplies offers reliable <br />notification power with unprecedented versatility. The power supplies <br />offer either 6 or 10 amps of continuous power through 4 or 6 outputs <br />respectively. Each output is rated at 3 amps and it may be used <br />continuously without any derating. The power supply operates on <br />either 120 VAC or 220 VAC power input and has a regulated 24 VDC <br />output. In addition, the power supply can charge up to 55 AH batteries <br />and leads the industry in housing up to 18 AH batteries. The cabinet <br />is constructed out of 18 gauge cold rolled steel and has a durable red <br />powder coat finish. In addition, a key lock is provided for securing the <br />door. Ample electrical knockouts are provided on the sides and the top, <br />allowing the installer options for running wires and maintaining the <br />correct separations. <br />The power supply offers an industry leading Quadrasync function <br />that allows for multiple strobe circuits of different brands to be <br />synchronized to flash at the same time. The power supply can have <br />four different brands each connected to its own circuit and all the <br />strobes flash together. Each output can independently be configured to <br />provide one of four synchronizations or steady power. This provides <br />unequivocal flexibility in new and retrofit installations. The power <br />supply can be configured to synchronize AMSECO®, Gentex®, <br />Wheelock® and System Sensor® strobe devices. Each output can <br />be configured to the same sync protocol or set independently. In <br />addition, the power supply has an input Pass Thru mode which <br />allows the outputs to follow the input signal from a non -supported <br />synchronization protocol. The power supply will recognize the type <br />of input being supplied and pass this through to the outputs with <br />PSN Series <br />Power Supplies <br />0 SIGNALING <br />C UL US <br />LISTED <br />the same pattern. This input pass through can be selected on each <br />output independently. The power supply contains simple dipswitch <br />programming and LED indicators providing the installer the ability <br />to correct any possible faults. A Trouble Memory is provided to <br />allow an installer to review past troubles and make the necessary <br />repairs. Each output has an LED to pinpoint the exact circuit where <br />a trouble may have occurred. Relays are provided for monitoring the <br />general system and AC failure. Each output and be independently <br />configured for various applications and installations. Each output can <br />be independently configured for Class A or Class B operation, constant <br />power, ANSI Temporal Code 3, Single, Multiple or Combo Inputs or <br />Door Holder Power. <br />Technical Specifications <br />Size (HxWxD) <br />161/8"Wx16'/'Wx3%"D <br />Enclosure <br />Eighteen (18) gauge sheet steel with hinged, locked door <br />120VAC @ 60Hz <br />Power Input <br />220/240VAC @ 50Hz <br />5.1 Amps @ 120 VAC <br />2.5 Amps @ 240 VAC <br />Current <br />75mA Standby & Alarm (no external load) <br />Input Voltage <br />15mA @ 8 — 33 VDC <br />Trigger <br />Terminals <br />18-12 AWG <br />Temperature <br />32° F to l20oF (0°C to 49°C) with a maximum humidity of 93% <br />non -condensing <br />NAC Output <br />3 Amp max per NAC, Regulated <br />Battery Charging <br />27.3 @ 1A, can support 7 — 55Ah batteries <br />Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br />8910013 - REV E • 05/21 PAGE 1 OF 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.